Standard configuration
The Aalborg CHB design consists of a large furnace welded
to vertical, plain-type convection tubes with spiral inserts. The
low-alloyed plate material is easy to weld and is highly durable to
prevent cracking.
Aalborg CHB boilers have fully water-cooled furnaces and can be
equipped with various burner types. The boiler comes complete
with connections, foundation, inspection hatches, manhole, hand
holes, insulation with sheeting as well as all valves and fittings.
Other standard features include:
• Modulating boiler water regulation
• Burner type according to preference and the type of fuel used
• Alfa Laval Gas valve units (GVU) and Methanol valve units
(MVU) for alternative fuels
• Processor-based control system
• Control panel with touchscreen interface for all necessary
operation, communication, safety and alarm functions
• Spare parts according to classification society demands
A pressurized deaerator ensures optimal feedwater quality
by thermally degassing dissolved oxygen and other non
condensable gases. This significantly reduces corrosion risk
and improves the reliability and longevity of the boiler system.
Technical data
Aalborg CHB boilers offer capacities ranging from 0.75 to 8 t/h.
Standard design pressure is between 10 and 18 bar(g), with
thermal output up to 6 MW. The table below shows capacities
and dimensions for the standard product range.
Leave a comment