The HPNC boiler is supplied in 9 different standard sizes, with
steam effect ranging from 125 to 2.500 kW. The standard boiler
is designed to operate at steam pressures up to 90 barg.
The boiler’s robust coil type design (see illustration page 2)
is based on thermal fluid heaters, which ensure:
• Flexibility in absorbing thermal expansions, a feature that
will ensure low stress levels in the boiler tubes and thereby
also long life time
• Efficient heat transfer as gas flow is perpendicular to tube
direction creating turbulence
• Efficient cooling of tube sections
• Verified pressure loss calculations (water/steam flow) that
provide assurance of cooling and no overheating
Highest possible efficiency is ensured through a compact
design, and reliable operation is guaranteed by using high
quality instrumentation.
Only high pressure grade steel tubes are used to ensure
high reliability.