Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Hitachi 560NMD11 DIN Rail Integrated Managed Switch

Applications

The DIN-rail mountable 560NMD11 is a manageable plug-and-play Layer 2 switch.

It offers four auto-negotiating Fast Ethernet RJ45 ports with automatic MDI/X (automatic cross detection and correction),

A two-wire SDSL port for dedicated copper cables and an SFP (Small Form Factor Pluggable) module slot for fibre optic transceivers.

Ethernet can be distributed within the station via the switch’s four RJ45 ports.

The SDSL port can be used to connect copper stations with a maximum distance of 20 km (0.8 mm diameter).

Depending on the SFP modules fitted, the device can achieve spans of up to 40 km over fibre-optic cables.

The switch provides a redundant topology via (fast) spanning tree protocol.

For documentation purposes, the Ethernet ports are labelled 1 to 4. The SDSL ports are connected via snap-in connectors.

There is no specific uplink port. All ports are functionally identical.

The link and speed status of each Ethernet port and SDSL port is indicated by the status indicators on the right (see ‘Connectors and Indicators’).

With respect to IEEE 802.1Q VLAN frames, the switch can be configured in VLAN or transparent mode.

In transparent mode, the switch does not change any frames or frame TAGs;

In VLAN mode, the switch can be configured to support multiple applications, such as trunks or access ports.

The switch can support quality of service if it uses IEEE 802.1p-compliant frame formats.

The switch can divide frames into up to four queues, which can be configured as priority-based queues or weighted fair queues.

The 560NMD11 uses a wide-range power supply and operates from 24 to 60 V. The switch itself, the Ethernet ports, and the Ethernet ports can be connected to the switch.

The switch itself, the Ethernet ports, as well as the SDSL connections, RS-232 interfaces, and SFP transceivers are hot-swappable.

Connectors and Indicators

The 560NMD11 switch consists of four equal RJ45 Ethernet ports, an SDSL transceiver,

one SFP transceiver slot, and two RS-232 connectors for configuring and transferring serial data.

Each RJ45 port can be connected to a Cat. 3 (10 Mbps) or Cat. 5 (100 Mbps) Ethernet cable with a maximum length of 100 metres. The cables can only be used for internal connections.

Crossover cables are not required because the RJ45 ports of the 560NMD11 switch support automatic MDI/X.

The SDSL interface can be www.cniacs.com connected to a customer-provided two-wire copper cable. 0.8 diameter copper cable has a maximum connection distance of 20 km and a transmission rate of 192 kbps.

Depending on the distance, the transmission rate can be configured up to 11 Mbps.

The status of the Ethernet and DSL interfaces can be monitored by two LEDs.

For the Ethernet port, these are located on the lower and upper part of the RJ45 socket.

Woodward CPC-II Electrohydraulic Current Pressure Converter

Features

 Actuators and self-cleaning valves are 4 times stronger with ‘sludge buster’ technology

 Patent-pending ‘Sludge Buster’ cleaning technology

 Advanced control algorithms and diagnostics

 Redundant optimum control configuration

 Same mounting base footprint as the CPC*

 Enhanced feature benefits:

 Removes 40 μm size dirt and reduces or eliminates filter/screen service work

 Removes sludge build-up without compromising operational integrity

 Industry-leading stability and buffer-free, precise throttle control

 Configuration flexibility to meet your system needs

 Easily upgrade your existing CPC* or Voith E360 I/H

CPC-II Upgrade Programme

(Current Pressure Converter, Generation II)

Maximise uptime with Woodward’s Dirt Buster www.cniacs.com technology Upgrade with Woodward’s CPC-II Electrohydraulic Current Pressure Converter

your Woodward CPC* or Voith E360 I/H throttle controller.

The CPC-II solves the turbine market’s number one reliability problem: oil contamination.

CPC-II:

 removes 40 μm sized dirt, reducing or even eliminating turbine control filter maintenance altogether!

 removes sludge build-up without compromising operational integrity

 features industry-leading stability and snubberless precision throttle control

 Easily upgrades existing CPC or Voith converters

The power of the CPC-II is combined with Woodward’s industry-leading control point algorithms, advanced diagnostics and PC-based service tools.

This powerful solution provides stable control during normal turbine operation and trouble-free control in the event of a plant failure.

By minimising process overshoot or undershoot conditions, you can maximise uptime and increase productivity.

Mark V-Series DS200CVMAG1AEB Generator Control Turbine Boards

About the DS200CVMAG1AEB

As mentioned above, this DS200CVMAG1AEB printed circuit board product was originally manufactured for placement in General Electric’s Mark V family of turbine control systems.

As you may have guessed, this DS200CVMAG1AEB product belongs to the Mark V family in the popular Steam,

wind and gas turbine automatic drive system components with specific applications in control and management systems, and was considered a legacy series for General Electric as it was eventually discontinued a few years after its initial release.

This larger Mark V series of DS200CVMAG1AEB Printed Circuit Boards or PCBs for short, while existing as a legacy series, is

but is also part of General Electric’s recently released line of products utilising their patented Speedtronic control system technology.

While this DS200CVMAG1AEB PCB can be functionally described as a generator control turbine board, the original PCBs developed with this function were not.

However, the Mark V series products originally developed with this functionality were missing all three parent PCBs of the DS200CVMAG1AEB PCB three important product revisions of the DS200CVMAG1 parent PCB.

Hardware Tips and Specifications

The GE Generator Control Turbine Board DS200CVMAG1AEB contains two 16-pin connectors and one 2-pin connector. The board is also equipped with 6 test points.

The GE Generator Control Turbo Board DS200CVMAG1AEB can be damaged by static electricity, so care must be taken when handling and installing the board.

When you open the box in which the board was shipped, you will notice that the board is packaged in a sealed plastic bag.

When the bag is sealed, it serves multiple purposes. www.cniacs.com It protects the board from dust, dirt, and other contaminants, as well as water or other liquids that may spill onto the board.

Firstly, the bag prevents static electricity from damaging the board. Consider the static buildup that can occur when you walk around with your board.

The air around you can cause static electricity to build up on your body and the board. Touching surfaces and walking on certain surfaces can also cause static buildup.

With this in mind, it is best to avoid carrying your board unless you are installing it. Keep in mind that the dry air you encounter in cold weather can lead to greater static buildup.

The GE Generator Control Turbine Board DS200CVMAG1AEB is shipped to you with a wrist strap that allows static electricity to drain away from your body and the board.

One end of the wrist strap wraps around your wrist and the other end is used to clip onto a metal surface, such as the legs of a workbench.

Whilst the static sensitivity of such DS200CVMAG1AEB printed circuit boards and the specification of installation procedures are important.

Mark V Series DS200CDBAG1 Contactor Driver Boards

About the DS200CDBAG1

As previously mentioned, this DS200CDBAG1 printed circuit board product, or PCB for short, is a contactor driver board manufactured by General Electric for placement in its Mark V turbine control system series of automatic drive assemblies. This DS200CDBAG1 PCB is no longer actively produced by the larger Mark V series, and its eventual discontinuation was necessary given the industry-wide obsolescence of many of its products. With that in mind, the Mark V series to which this DS200CDBAG1 printed circuit board, or PCB for short, belongs remains the final instalment of General Electric’s Mark product line, incorporating its patented Speedtronic control system technology into its various products. This DS200CDBAG1 PCB is defined in the original instruction manual material via the official functional product description of the contactor driver board, and it does exist as a revised version of the original base for this intended Mark V series functional role, as indicated by its DS200CDBAG1 functional product number without any trailing, alphanumeric digits denoting a revision.

Hardware Tips and Specifications

The GE Contactor Driver Board DS200CDBAG1 opens and closes the contactors in its larger Mark V Series Autodrive assembly. Before touching the board for installation, be sure to disconnect power to the drive and test the board to ensure that there is no power in the board. Also, do not remove the board while the drive is powered. Static electricity can damage the board. Use a grounding strap to work on the board and store the board in a static protection bag. the DS200CDBAG1 has a jumper. jp1 is a 3-pin jumper for factory test purposes only. Keep pins 1 and 2 covered for normal operation. When pins 2 and 3 are covered, it is for factory use only. www.cniacs.com The DS200CDBAG1 also has a potentiometer to control the amount of current applied to the contactor coil. This is set at the factory and it is best practice not to change it. Voltage limiting in the assembly of this DS200CDBAG1 Mark V Turbine Control System series product is handled in the same manner as most General Electric Speedtronic products; accepting a variety of voltage-limiting hardware components including capacitors, rectifiers, diodes, and integrated circuits through its internal assembly. In addition to this, the base board and components of this DS200CDBAG1 product receive the normal level of protection from daily wear and tear and insulation due to its normal style of PCB protective coating, which wraps and protects the individual DS200CDBAG1 board hardware components according to their functional priority.

The DS200CDBAG1 also features test points that can be used to test board operation. One test point is a common reference point for the board. One test point is a 15 VDC test point referenced to the common reference point. One test point is for contactor driver reference voltage. connector 1TB on the DS200CDBAG1 board consists of four sections (1TBA, 1TBB, 1TBC, and 1TBD). Carefully note the location of the connector on the board and use a screwdriver to pry the sections apart. The connectors on the replacement board may be in different locations, so care must be taken to plug the sections into the correct connectors. There is also a fuse available for this DS200CDBAG1 Mark V series assembly; this fuse is designated in the original instruction manual material as a 4 amp, 125 V, 2AG slow blow fuse and can be replaced if it continues to blow (this is usually applicable to any DS200CDBAG1 board assembly).

Mark V Auxiliary Interface Board DS200ADGIH1AAA

The DS200ADGIH1AAA is 6 inches long and is designed to be mounted in the drive’s board cabinet.

It has four screws that align with a location on the board rack for screw mounting.

Test points provide a means of testing the circuitry on the board. However, only qualified service personnel should test the board.

Service personnel must have test equipment calibrated www.cniacs.com and designed for the task. The controls must be set up correctly and the probes must be designed for use with the tester.

Place the board on a flat surface and place a protective bag underneath the board.

In addition, due to the risk of static electricity, service personnel must wear a wrist strap at all times.

When the wrist strap is properly fitted, one end of the strap is attached to the wrist and the other end is clipped to the metal leg of the workbench or desk.

It can also be attached to other metal structures. Static electricity is attracted to the metal ground and then discharged from the circuit board or your body.

Another appropriate step to reduce static build-up is to avoid moving the board around while holding it in your hands. The friction of walking can cause static buildup.

This is especially true in cool, dry weather conditions. If you do not have a wrist strap, you can also touch the static bag containing the board to a metal structure, such as a chair or metal table leg.

Mark V Series DS200AAHAG1ADC ARCNET Connection Boards

This DS200AAHAG1ADC allows connection between externally placed modules or I/O cores and the control engine. This board is used to connect these units to the ARCNET communication protocol.

The board is used in combination with the UCPB board containing the 486DX processor/CPU and the UCIA main board containing the 196 processor chip. This chip is used to convert the pressure sensor signals.

Unfortunately, no Berg-type manual movement hardware jumpers or other customisable hardware is inserted into the internal components of this DS200AAHAG1ADC product.

This DS200AAHAG1ADC printed circuit board or PCB for short benefits from having a DS200AAHAG1ADC functional product number.

This number identifies many key hardware specifications, including this DS200AAHAG1ADC PCB:

. Common Mark V Series Assemblies

. Domestic Original Manufacturing Base

.AAHA Functional Product Abbreviation

. Normal PCB Coating Style

. Group I Mark V Series Product Grouping

.A Level Primary Functional Revision

.D Secondary Functional Revisions

.C level drawing configuration revisions

The DS200AAHAG1ADC includes multiple BNC connectors. www.cniacs.com They are used to download files to the control engine, which typically occurs at a rate of 100 Hz or 10 ms.

The board is commonly abbreviated AAHA and includes other connectors. the AAHA includes an APL ArcNet communication link and a 2PL connector for distributing power from the TCPS board in the core.

The other connectors on the board (such as EPL and EBNC) are usually unused. The board is marked with several factory-printed naming labels, starting with the GE logo.

It also includes its ID markings and codes to help the user with orientation and wiring. Most of the board’s components are labelled with reference names.

The DS200AAHAG1ADC board’s two relays include relay diagrams directly on top of them that are clearly visible to an installation or troubleshooting engineer or technician.

For more information about the DS200AAHAG1ADC board, refer to GE original manuals and user guides, such as GEH-6353B.

Mark V Series DS200ADCIG1ADB Printed Circuit Boards

DS200ADCIG1ADB Technical Specifications

About the DS200ADCIG1ADB

General Electric’s DS200ADCIG1ADB Genius adapter board is used in the company’s Mark V turbine control system.

The Mark V is one of the more complex of the company’s Speedtronic turbine control systems, which range from the Mark I (originally released in the late 1960s) to the Mark VIe.

Speedtronic systems have been used for decades www.cniacs.com for their reliability and flexibility in the management and control of industrial gas and steam turbine systems.

This particular DS200ADCIG1ADB printed circuit board is not the original Genius adapter board product manufactured for the Mark V turbine control system family.

The original Mark V series Genius adapter boards are the three key product revisions of the DS200ADCIG1ADB Genius adapter board missing this DS200ADCIG1 parent printed circuit board.

Hardware Tips and Specifications

As with any GE printed circuit board, Mark V series or otherwise, the internal assembly of this DS200ADCIG1ADB PCB utilises its own specific series of hardware component inclusions and specifications in order to implement the functionality in the Mark V series.

 to realise the functional state of the Mark V series. For the uninitiated, the DS200ADCIG1ADB is a rectangular board with holes drilled at the factory corners for mounting.

Each of these factory drilled holes should be insulated in accordance with the potentially damaging surface voltages of this DS200ADCIG1ADB PCB.

In terms of factory-printed diagnostic labels, the DS200ADCIG1ADB Genius Adapter board carries the board ID, a code to aid in locating and wiring the board, and the General Electric logo to ensure authenticity.

The board has two programmable memory chips (PROMs) as well as other integrated chips. the PROMs can be moved from the old component to the new one, simplifying replacement.

Please note that both the DS200ADCIG1ADB board and the PROMs are sensitive to static electricity. We recommend wearing a grounding strap during installation or any form of maintenance; this is supported by General Electric’s instructional manual material.

This DS200ADCIG1ADB includes single-pin connectors, multi-pin connectors, and plug connectors, as well as multiple jumper switches that allow you to configure the board as needed.

As mentioned earlier, most of the components are labelled with some sort of reference indicator, although the true function of these jumpers is unclear due to the lack of relevant instruction manual documentation on the internet.

ABB Measurement and Analyser AO2000-LS25 Laser Analyser

General Purpose and Explosion Proof

Easy Measurement

This is a precision instrument It is a precision instrument using state-of-the-art electronics and laser technology.

Installation and maintenance The instrument requires care and preparation for installation and maintenance. Failure to do so may damage the instrument and void the warranty.

1.2 Measurement principle

The analyser is an optical instrument based on tunable diode laser absorption spectroscopy (TDLAS).

The analyser is an optical instrument based on tunable diode laser absorption spectroscopy (TDLAS) and is used for continuous on-site monitoring of gases in chimneys, pipelines, process chambers or similar.

The analyser measures the average gas concentration along the line-of-sight path using a transmitter/receiver configuration (mounted in a relative diameter installation).

The measurement principle is infrared single line absorption spectroscopy, based on the fact that each gas has a different absorption line at a specific wavelength.

The measurement principle is shown in Figure 1-1. The laser wavelength is scanned over the selected absorption lines of the gas to be measured.

The absorption lines are carefully selected to avoid cross-interference from other (background) gases. Cross interference from other (background) gases.

The detected light intensity varies with the wavelength of the laser. In the optical path between the transmitter and receiver, the target gas molecules absorb the laser wavelength.

Absorption of target gas molecules in the optical path between the transmitter and receiver. In order to improve the sensitivity, wavelength modulation technique is used.

In order to increase the sensitivity, a wavelength modulation technique is used: the laser wavelength is slightly modulated while scanning the absorption line.

The detector signal is spectrally decomposed into harmonic frequency components of the laser modulation frequency.

The second harmonic of the signal is used to measure the concentration of the absorbed gas. Both line amplitude and line width are Both line amplitude and line width are extracted from the second harmonic line shape.

Therefore the measured concentration is www.cniacs.com not sensitive to changes in the line shape (line amplitude and line width). The measured concentration is not sensitive to line shape changes (line width and line width) caused by background gases.

Note: The analyser measures only the concentration of free molecules in a given gas and is therefore not sensitive to molecules bound to other molecules in complexes and molecules attached to or dissolved in particles and droplets.

Care should be taken when comparing results with those obtained by other measurement techniques.

Fanuc IC200PWR002 Module Extended Power Supply Unit (PSU) for Versamax Series

Description.

The IC200PWR002 is a power supply module that is part of the VersaMax product family, currently part of Emerson Automation and previously manufactured by GE Intelligent Platforms. The power module is a 24 VDC extended power supply with an input supply voltage of 18-30 VDC. it has output voltages of 5 VDC and 3.3 VDC, and a total output current of 1.5 A, with a maximum of 1.0 A at 3.3 VDC and 1.5 A, and a maximum at the 5 VDC output.

About the IC200PWR002

The IC200PWR002 is a power supply module that is part of the VersaMax platform, which was previously manufactured by GE Intelligent Platforms (GE IP) and is now produced by Emerson Automation. This module can be used as a mains power supply or a power booster carrier. When used as a main power supply, this module is used to power a VersaMax that is enabled for installation and connected to a backplane. When used as a booster power supply, this module is mounted on the booster bracket and is used as a supplemental power supply. It has five screw type terminals located on the bottom front panel of the module. The two terminals on the left side are the www.cniacs.com DC and -DC terminals, while the third terminal is the ground terminal. The last two terminals do not need to be connected.

The IC200PWR002 is designed to operate from an input supply voltage of 18-30 VDC with a nominal supply voltage of 24 VDC.The module has an input power of 11 watts and a hold-up time of 10 milliseconds. Its inrush current is rated at 20 amps with a maximum duration of 6 milliseconds at 24 VDC and a minimum duration of 25 amps for 6 milliseconds at 30 VDC. Module output characteristics include output voltages of 5 VDC and 3.3 VDC with an output current of 1.5 amps, maximum at 3.3 VDC, and 1.0 amps at 5 VDC, provided that the output current does not exceed the maximum output of 1.5 amps. The power module is also fitted with internal short circuit, overload and reverse polarity protection.

This power supply module is primarily used with VersaMax I/O modules, Network Interface Units (NIUs), and Central Processing Units (CPUs).

The GE Fanuc IC200PWR002 Extended Power Supply Module is used to power backplane devices such as the I/O, CPU, and NIU. If it is connected to the network interface unit (NIU) or the central processing unit (CPU), the expansion power supply module acts as the main power supply. However, if it is connected to a power booster bracket, the extended power supply module acts as the auxiliary power supply.The output and input voltages of the IC200PWR002 module require a DC power supply. It has output ratings of 3.3 volts DC and 5 volts DC, and an input rating of 24 volts DC.The output voltages of 5 volts DC and 3.3 volts DC determine the output current of the module, which should not exceed 1.5 amps. It has an extended power supply option, but no isolated power supply.

A-B 6180P-12KPXP AC Powered Display Computer

Description.

The 6180P-12KPXP display computer is an AC-powered display computer for the Allen-Bradley/Rockwell Automation VersaView Plus series.

It operates on voltages ranging from 90 to 264 volts AC and frequencies from 47 to 63 Hz. The 6180P-12KPXP display computer has two serial ports and two Ethernet ports.

The 6180P-12KPXP display computer can be controlled from a keyboard and touch screen.

About the 6180P-12KPXP

The Allen-Bradley 6180P-12KPXP VersaView Plus 1200P Integrated Display Industrial Computer is a performance package that has only one keyboard for input.

It has a 12.1-inch screen that is a 256K-colour colour matrix thin-film transistor type with an inherent resolution of 800 x 600 and a display area of 9.7 x 7.3 inches.

The screen response time is 20ms and the viewing angles are 40º vertical and 60º horizontal. This computer’s keyboard input consists of alphanumeric keys and 36 programmable function keys.

This computer is rated for NEMA 1/4/12 type and IP66. and uses panel mounting.

The entire 6180P-12KPXP computer weighs approximately 16 kg or 35.3 lbs. and measures 12.25 x 19.01 x 8.86 inches.

The processor installed on this computer is an Intel www.cniacs.com Core Duo processor at 2 GHz and the system chipset is an Intel 945GME.

Its memory is expandable as it has 2 dual-channel DDR II DIMM slots that can handle up to 2 GB of memory per slot for a total of 4 GB.

The 6180P-12KPXP computer also features a variety of I/O ports, notably 2 serial ports, 1 DVI port, 2 front USB ports, 4 rear USB ports, and 1 parallel port, as well as 2 RJ45 Ethernet LAN ports capable of handling 10/100/1000 Mbps speeds. To prevent overheating.

This computer is fitted with a processor heatsink, two chassis fans and a PSU fan. It is also equipped with three audio jacks, which are microphone jack, line jack and line out jack.

Installed status indicators include Power/Standby, NumLock, Caps Lock and HDD/ODD/FDD activity.

There are also three disk drives, a slim DVD-RW disc drive, a floppy drive and a 3.5-inch 160 GB hot-swappable hard drive with a SATA interface.

The 6180P-12KPXP has an AC power consumption of 144 VA (1.4 A at 100V rms and 0.6 A at 240V rms).

It has an autoranging input voltage of 90-264 V AC and a line frequency of 47-63 Hz. At peak, it has 1 g of operating vibration and 2 g of non-operating vibration.

Its operating shock is 15 g and non-operating shock is 30 g at 1/2 sine and 11 ms.

Search for products