HRBX01K02 ABB Ability™ Symphony® Plus Hardware Selector

The cRBX01 Compact Remote Bus Extender is a fibre optic repeater module for the Symphony Plus redundant HN800 IO bus.

Module.

The cRBX01 fibre optic repeater transparently extends the HN800 IO bus of the SPCxxx controller.

The cRBX01 repeater requires no configuration, and the remote IO or communication module has the same functionality, performance, and capacity as the local module.

The HRBX01K02 is a www.cniacs.com redundant repeater kit that includes 2x cRBX01 modules + 1x RMU610 base.

Features and Benefits

The cRBX01 Fibre Repeater Module supports up to 60 HN800 devices per remote link.

The fibre optic HN800 bus uses a star topology (point-to-point) with up to 8 remote links per controller.

Each remote link can support up to 60 HN800 devices (SD Series IOs or communication modules).

Each link can be up to 3.0 kml long using 62.5/125 µm multimode fibre optic cable with cRBX01.

ABB PM866AK01 Compact Product Suite Hardware Selector

The CPU board contains the microprocessor and RAM memory, real-time clock, LED indicators, INIT button, and CompactFlash interface.

The PM866 / PM866A controller’s backplane has two RJ45 Ethernet ports (CN1. CN2) for connection to the control network and two RJ45 serial ports (COM3. COM4).

used to connect to the www.cniacs.com control network, and two RJ45 serial ports (COM3. COM4).

One of the serial ports (COM3) is an RS-232C port with modem control signals.

The other port (COM4) is isolated for connecting configuration tools.

The controller supports CPU redundancy for increased availability (CPU, CEX-Bus, communication interfaces and S800 I/O).

Easy DIN rail mounting/dismounting procedure using a unique sliding and locking mechanism.

All baseboards have a unique Ethernet address that provides hardware identification for each CPU.

This address can be found on the Ethernet address label on the TP830 backplane.

Features and Benefits

ISA safety certified – learn more

Reliability and simple troubleshooting procedures

Modular and incrementally expandable

IP20 rated protection, no enclosure required

Controller can be configured with 800xA control generator

Controller is fully EMC certified

Segmented CEX buses using a pair of BC810 / BC820

Hardware based on the best communication connection standards (Ethernet, PROFIBUS DP, etc.)

Built-in redundant Ethernet communication ports

Woodward 505DR Dual Redundant Turbine Controller

The 505DR® Dual Redundant Turbine Controller is a state-of-the-art digital control platform designed to reliably control and protect single-valve and single-pump steam turbines.

The benefits of dual redundancy maximise turbine reliability and availability.

Redundancy is managed at the operating system level using Woodward’s RTN (Real Time Network), allowing ultra-fast switching and ‘bufferless’ transitions.

The controller utilises the same unique PID architecture as the proven 505XT, making it the ideal controller for controlling speed, load,

parameters such as pumping collector pressure, exhaust collector pressure or connection line power. The dual redundant version inherits features such as the Opti-Tune self-tuning PID and ratio limiter.

The controller includes the following turbine protection features to ensure that the turbine and its driven loads (compressors, pumps, generators) operate within design limits:

– 3 critical speed avoidance bands

– Overspeed prediction and shutdown protection

– Configurable under- or over-pressure shutdown logic

– Minimum and maximum speed and load settings

– Maximum low-pressure stage overpressure limitation

– Minimum high pressure stage flow limiting

Ethernet and serial communications allow for easy integration into plant controls or process control systems.

The 505DR can be configured with an optional integrated user interface, including an 8.4-inch multi-language graphical display.

Description

Like the MicroNet Plus, the 505XT system designates one controller as the System Controller (Syscon), actively controlling the fan.

The second device is configured as a www.cniacs.com backup. The system automatically evaluates the health of the Syscon and initiates a fast switchover in the event of a failure.

Switchover can also be initiated manually. The system closely synchronises the Syscon’s software status and memory with the backup, ensuring that the control output remains stable and does not affect turbine operation (a true ‘bufferless’ switchover).

If the optional HMI version is selected, the display and keypad are redundant (input from either keypad will command Syscon, and the display can be independently selected to show different screens.

For example, one screen can display speed and speed settings, and another can display a steam map.

Woodward’s optional RemoteView programme allows remote monitoring from any networked PC.

The programme can be used either with the rear panel mounted version (as the main HMI) or as an additional remote monitor to the HMI version.

The optional FTM (Field Terminal Module) allows easy multiplexing of redundant signals and facilitates fast installation and commissioning.

Emerson M-Series DC to DC System Power Supplies

About DeltaV™ System Power Supplies

Power supplies – systems can’t operate without them.DeltaV™ System Power Supplies provide you with the most efficient and reliable power solutions available.

DeltaV power supply kits provide www.cniacs.com power to the system electronics and to the field. This is all the power you need for your DeltaV system.

Benefits

DC/DC system power supplies are plug-and-play components. They fit any power carrier, including horizontal 2-width and vertical 4-width carriers.

These carriers contain an internal power bus that connects to the controller and I/O interfaces, eliminating the need for external wiring. The carriers are easily mounted on T-shaped DIN rails!

Flexible and cost-effective, DeltaV DC/DC system power supplies accept 12V DC and 24V DC input power.

Modular construction and load-sharing capabilities of the power supplies allow you to add more power to your system or provide power redundancy.

Safety. Your I/O is always accurate because I/O subsystems and controllers are always supplied with stable, accurate 12V DC or 5V DC power. Power supplies are EMC- and CSA-compliant; notification is immediate in the event of a power failure; and system and field power supplies are completely isolated.

Simplified system power supply. System power supplies provide more current on the 12 VDC I/O interface power bus, eliminating the need for 24 to 12 VDC bulk power supplies. All controller and I/O power is now available from the factory 24 VDC bulk power supply.

Emerson DeltaV Distributed Control System MX Controller

INTRODUCTION

The MX controller provides communication and control between ffeld devices and other nodes on the control network. Control strategies and system configurations created on earlier DeltaV™ systems can be used in this powerful controller.The MX controller has all the features and functionality of the MD Plus controller, but twice the capacity.

The control language implemented in the controller is described in the Control Software Suite product data sheet.

Advantages

Right-Sized Controller

The MX controllers complement the MQ controllers by providing a larger capacity controller for applications requiring greater control capability:

2 X control capacity

2 X user configurable memory

2 X DST counts

DeltaV™ MX controllers and DeltaV I/O subsystems are easy and quick to install.

Post change. You can easily upgrade an MQ controller to an MX to handle project scope changes later in the project The MX has the same installed footprint as an MQ controller, but twice the performance. Simply replace the MQ with the MX, and then

All existing configurations, documentation, www.cniacs.com and hardware design remain intact.

Redundant Architecture: MX controllers support 1:1 redundancy for increased availability. Existing MD/MD Plus or MQ controllers are upgradable and powerful online!

Increased Productivity

Self-addressing.The DeltaV controller is unique in its ability to automatically identify itself within the DeltaV control network.

When the controller is powered up, it is automatically assigned a unique address – no dip switches, no connections – plug and play!

Automatic Location. The physical location of the controller is easy to find.

LEDs on the face of the controller can flash to provide a strong visual cue.

Automatic I/O Detection. The controller recognises all I/O interface channels on the subsystem. As soon as an I/O interface is plugged in, the controller knows the general characteristics of the ffeld device managed by that I/O interface. This reduces the worthless engineering associated with configuration – simple!

Connection to electronic commissioning and wireless I/O.

Starting with DeltaV v14.3. CHARM and wireless devices connected via the CHARM I/O card (CIOC) and the Wireless I/O card (WIOC) can be assigned to the MX controller.

This makes it easier than ever to add I/O to existing controllers by simply adding a CIOC and/or WIOC to the DeltaV zone control network.

ABB M4M Network Analyser

OVERVIEW

The M4M network analyser includes versions with the Profibus DP-V0 communication protocol (M4M 20 Profibus and M4M 30 Profibus).

1.1 Profibus

Profibus stands for Process Field Bus.

Profibus is a fieldbus www.cniacs.com according to IEC 61158/EN 50170. which is mainly used in industrial automation and process areas.

Profibus is a single-master-multi-slave communication network; it is an open, reliable and powerful fieldbus system.

It is characterised by its fast response time, its complete definition according to international standards and its ability to connect devices from different manufacturers (if all devices comply with the same standard).

Profibus also reduces wiring between network nodes, as it requires only one communication cable.

Profibus communication technology is based on a master-slave architecture:

– Every Profibus system requires at least one master (e.g. PC or PLC).

– Up to 127 devices (master + slave) can be connected to a single system.

– Profibus systems can be ‘multi-masters’; in this case, a ‘token’ structure is used in which only one master can communicate on the network at a time.

The M4M Profibus (M4M 20 Profibus and M4M 30 Profibus) type instruments are slave devices that implement the Profibus DP-V0 protocol.

The DP slave is a peripheral device that acquires input information and sends data to the central master.

According to the IEC 61158/EN 50170 standard, Profibus DP (decentralised periphery) is typically used to connect decentralised peripheral devices with fast response times.

The standard specifies node distances of up to 300 metres with bit rates ranging from 9.6 kbps to 12 Mbps, using standard cables and maintaining maximum operating speed.

ABB IORR2100-30 slap contactor

ABB’s IORR2100-30 is an I/O module typically used in industrial automation and control systems.

The module allows users to connect field devices (e.g., sensors, actuators, etc.) to a control system for data acquisition and sending control commands.

Specifically, the IORR2100-30 may have the following features:

Input/Output Functions: the module may support multiple types of input and output signals, such as digital input/output (DI/DO) or analogue input/output (AI/AO).

This makes it possible to interface with a wide range of different types of sensors and actuators.

Communication Interfaces: The www.cniacs.com IORR2100-30 may have one or more communication interfaces, such as Ethernet, serial communication, etc., to allow for data transfer with the control system.

Configuration and programming: The module may support configuration and programming through specific software tools to meet specific application requirements.

Modularity and expandability: As an I/O module, the IORR2100-30 may be a component in a control system that can be combined with other ABB or other manufacturers’ modules to build a complete control system.

Environmental adaptability: Considering the complexity of industrial automation environments, the module may have a certain degree of immunity to interference, as well as the ability to adapt to environmental factors such as temperature and humidity.

ABB’s IORR2100-30 I/O module is a highly integrated and feature-rich module designed to meet the diverse needs of industrial automation and control systems.

ABB variable pole contactors type R Control of AC and DC power supply circuits

Variable pole contactors type R and its variants (N.C. + N.O. pole contactors, couplers ……)

For controlling power supply circuits with a maximum voltage of 1000 V AC or 1500 V DC. They use common standard components.

Special versions are available with combinations of these components. Designed for long-term operation and demanding applications ABB R contactors are used in many applications around the world.

Widely used worldwide.

Flexible design

– Variable number of poles

– Adjustable number of auxiliary contacts

– Choice of N.O. and N.C. pole combinations

– Choice of mechanical or magnetic latching

Easy maintenance

– Direct access to all parts of the contactor

– Complete instruction manual

– Spare parts available

– Specialised service for bar contactors.

Excellent durability

– Mechanical durability up to 10 million operating cycles

– Mechanical switching frequency up to 1200 cycles per hour

– Electrical durability up to 350 000 operating cycles.

Ideal for heavy duty applications

– High braking and breaking capacity

– Fully compliant with the requirements of use categories www.cniacs.com AC-3. DC-3 and DC-5 (AC/DC motor control for mining, steel industry ……) .

Customised solutions

– More than 60 years of experience in customer projects

– Solutions according to specifications

– Pre-sales support to identify and define customer requirements

– Experts at your disposal to help you select a product or optimise a configuration.

Fanuc IC200CPU001 Configurable Central Processing Unit (CPU) Module

About the IC200CPU001

The IC200CPU001 is Emerson Automation’s VersaMax series of compact controllers, formerly known as the GE Intelligent Platform (GE IP).

It is a DIN-rail or panel-mounted central processing unit (CPU) module capable of handling up to 2048 discrete inputs

2048 discrete outputs and 34 KB of memory that can be allocated to user programs, analogue input and analogue output data, and internal registers.

The CPU is also equipped with 1024 points of discrete internal bits, 256 points of discrete temporary bits and 1280 points of global discrete bits.

The IC200CPU001 has a typical Boolean www.cniacs.com execution speed of 1.8 ms / K. It supports floating-point mathematical calculations and data processing, override functions

and is equipped with a battery-backed real-time clock (RTC) with an accuracy of 100 ppm (0.01%) or +/- 9 seconds/day.

for internal timer and counter commands, 23 ppm (.0023%) or +/- 2 sec/day @ 30C; and

100 ppm ((0.01%) or +/- 9 sec/day @ full temperature range for logic scheduling or scheduling-based logic sequences.

The available integrated communication ports for the IC200CPU001 are one (1) RS232 and one (1) RS485 communication interface.

These interfaces support a variety of industrial communication protocols such as SNP slaves, RTU slaves, and serial I/O and can be used to implement distributed I/O architectures,

Human Machine Interface (HMI), Supervisory Control and Data Acquisition (SCADA) systems, and other applicable and compatible partner devices.

These CPU modules are configured using CIMPLICITY Machine Edition Logic Developer, VersaPro or Control Programmer.

The IC200CPU001 CPU is a user-configurable CPU manufactured by GE Fanuc with 2 serial ports and 34 KB of configurable memory.

The CPU uses non-volatile memory to store programs. It supports programming in ladder diagrams and instruction lists.

It has 1024 points for discrete internal bits and 256 points for temporary bits.The global discrete bits of the CPU consist of 1280 points.

The Boolean execution speed of the CPU is 1.8 ms/K. The IC200CPU001 CPU supports floating point and overclocking.

The CPU is equipped with built-in RS-232 and RS-485 ports. For internal communication, the CPU uses SNP slave and serial I/O protocols.

The CPU’s memory is battery-backed and it has a real-time clock. The clock adds time stamps to critical time events during operation.

The real-time clock accuracy is 100 ppm over the entire temperature range.

The GE Fanuc Versamax IC200CPU001 CPU can be easily mounted using a DIN rail with power supply.

Fanuc IC200ALG230 VersaMax Analogue Input Module

About the IC200ALG230

The IC200ALG230 is an analogue input module from the Versamax modular I/O and control platform.

It is a compact analogue input module with four (4) individually configurable analogue input channels for voltage or current.

The module supports the interfacing of analogue signals, in particular unipolar 0 to 10VDC and bipolar +/-10 VDC voltage signals, as well as 4-20 mA current signals.

The IC200ALG230 is equipped with www.cniacs.com two (2) status LEDs for local reporting of the module’s operational status.

Specifically, the INT Power LED indicates that internally generated field power is being supplied and the OK LED indicates that backplane power is actively supplied to the module.

The analogue input module has two (2) jumpers for setting the module’s mode of operation, either voltage or current and unipolarity for bipolar data.

The IC200ALG230 has a built-in analogue-to-digital converter with a resolution of 4?A = 8 counts (configured for current operation) and 2.5 mV = 8 counts (for voltage configuration).

The module has a typical response time of 0.4 ms and a filter response of 5.0 ms.

The module’s input data can be configured to hold to a *later state or to go to a defined value if a module error is detected.

The IC200ALG230 can be fitted with an auxiliary I/O terminal for signal wiring.

The terminal part number is IC200TBM001. 002 or 005.

Additionally, the terminal I/O bracket is available with catalogue number IC200CHS001. 002 or 005.

In addition, the terminal I/O bays can be used with compact terminal I/O bays catalogue number IC200CHS001. 002. or 005. catalogue number IC200CHS022. 025. and connector I/O bays part number IC200CHS003.

The GE Fanuc IC200ALG230 module is part of the Versamax product line.

It is an analogue input module compatible with 4 current inputs or 4 voltage inputs.

The IC200ALG230 analogue input module does not require an external power supply because it draws power from the power supply on the Versamax PLC backplane.

It is designed to interface with a Versamax PLC or Programmable Logic Controller system in a commercial or industrial environment.

All 4 of its inputs are single-ended and they are arranged in groups of 1. The IC200ALG230 Analogue Input Module draws 5 mA of backplane current at 125 V output voltage.

By default, its input voltage is +/- 10 volts DC bipolar, but it can be configured to have 0 to 10 volts unipolar.

Configuration of the GE Fanuc Versamax IC200ALG230 Analogue Input Module can be accomplished using 2 jumpers on the carrier terminals.