Braking energy

Brake resistor activation is integrated in the form of a

brake chopper. A regenerative resistor is connected exter

nally. This paves the way for optimal dimensioning and

also reduces the volume of the control cabinet.

Line filter

To optimize configuration from a cost perspective, line

filters are always connected in series outside the device.

Several power modules can thus be grouped for each line

filter resulting in reduced costs for the system as a whole.

Temperature-dependent fan control

The fan is controlled relative to the temperature inside

the device. This leads to a reduction in energy consump

tion and therefore lowers the overall costs of a system.