Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Emerson Ovation™ Power System (5X00785G09)

Features

Redundant power configurations, each with separate external wide range AC or DC feeds

Separate primary and auxiliary power supplies in both primary and auxiliary configurations

Dual wide-range input capability

Diode auction feed

High efficiency power supplies

Modular fanless system

Redundant feeds to each controller chassis and I/O module

Continuous system monitoring

OVERVIEW

Emerson has developed a DIN-rail mounted power supply that includes four modular fanless power systems to provide reliable and stable power to Ovation™ controllers and I/O modules.

The Ovation controller power supply systems are configured in redundant configurations, each with a separate external wide-range AC and/or DC input feed.

Dual diode auction 24 VDC outputs are used to power each controller chassis and associated I/O modules, as well as to power loop and contact wetting for the I/O modules.

A 48 VDC auxiliary power supply is available for loop and contact wetting if required.

Two separate output schemes are available:

24 VDC / 10 A / 240 W main power and 24 VDC / 10 A / 240 W auxiliary power.

24 VDC / 20 A / 480 W main power supply and 24 VDC / 20 A / 480 W auxiliary power supply.

Benefits

Benefits of Ovation power solutions include

Separate primary and auxiliary power supplies are easy to replace

No cooling fan required, greatly reducing the risk of failure

Diode auction feed ensures continuous power

New design improves efficiency, reduces heat generation and extends equipment life expectancy

Dual input (AC and DC) capability reduces spare parts

Hot-swappable power supplies enable in-line replacement

Quick installation of power supplies minimizes downtime and lost production

Power factor correction reduces power consumption

10 Amp Power Solutions

10 Amp power supply options include

Redundant Power Configuration (Primary and Auxiliary) includes separate 10 Amp Primary and Auxiliary power supplies supporting multiple input voltages (85-264 VAC @ 43-67 Hz or 90-375 VDC) with 240 W output power.

Emerson 1066 Liquid Analysis Fieldbus pH/ORP Transmitter

Features and Applications

The Model 1066 Fieldbus Transmitter supports continuous measurement of one liquid analysis input.

It is designed for easy internal access and wiring connections.

Analytical inputs: pH and ORP sensors with or without Rosemount Analytical preamplifiers, and Rosemount Analytical smart pH sensors.

Large Display: High-contrast LCD displays real-time measurement readings in large numbers and up to four additional variables or diagnostic parameters.

Digital Communications: Fieldbus ITK 6 Menus: Menu screens for calibration and programming are simple and intuitive. Plain language prompts and “help” screens guide the user through the steps.

All menu screens are available in eight languages. Real-time process values are displayed during programming and calibration.

Troubleshooting and Warning Help Screens: Troubleshooting and warning information is included in the Help screens to provide the user with helpful troubleshooting tips. These screen instructions are intuitive and easy to use.

Diagnostics: The transmitter continuously monitors itself and the sensors for problems. On-screen display banners alert technicians to faults and/or warning conditions.

Languages: Emerson extends its global reach by offering eight languages: English, French, German, Italian, Spanish, Portuguese, Chinese, and Russian.

Input Damping: Automatically enabled to suppress noisy process readings.

Smart Enable pH: Rosemount Analytical SMART pH feature eliminates the need for field calibration of pH probes by automatically uploading calibration data and history.

Automatic Temperature Compensation: pH measurements require temperature compensation. the 1066 will automatically recognize the sensor’s built-in Pt100 or Pt1000 RTD, or the temperature of an on-bus temperature measurement can be linked to the 1066 and used for temperature compensation.

Emerson VersaPoint I/O Input/Output Modules

VersaPoint I/O

The VersaPoint™ Distributed I/O System offers optimal compactness and flexibility while allowing users to install the right amount of I/O for each application.

Allows users to install the right amount of I/O for each application.

VersaPoint adheres to open communication standards, including Ethernet, Profibus-DP™, and DeviceNet™, for easy connection to a wide range of PLCs, DCSs, and PC-based control systems.

It is suitable for packaging and material handling applications as well as monitoring and data acquisition.

Superior Flexibility

VersaPoint’s modular structure allows it to be easily adapted to a wide range of applications. It accommodates a range of discrete and analog I/O modules, from 1-point to 16-point densities.

VersaPoint also supports a wide range of specialized modules, from RTD and thermocouple inputs to positioning and counting modules, virtually combining intelligent automation with the simplicity of endpoint technology.

Compact size

VersaPoint saves valuable control panel space by eliminating the need to plug in terminals.

Its compact and versatile design saves up to 50% of space compared to conventional systems.

Reduced Installation Time

Installing VersaPoint couldn’t be quicker: I/O modules can be quickly and securely fastened to the DIN rail.

Thanks to the integrated I/O terminals and internal power bus, VersaPoint reduces wiring by up to 80%.

Cost-effective solution

Fast installation, reduced cabling, and more efficient use of cabinet space all make VersaPoint a great value.

Cost savings continue during operation. Extensive built-in diagnostics make identifying faults routine, maximizing uptime.

Emerson DeltaV™ M-Series Product Description

I/O Cards

A variety of analog and discrete I/O cards are available to meet your specific requirements.

The following cards support simplex or redundant installation:

AI 4-20 mA HART 8 channels

AO-4-20 mA HART 8 channels

DI, 24V DC Dry Contact, 8 channels

DO 24V DC High-Side, 8 channels

AI (Plus) 4-20 mA HART, 16 channels

AO (Plus) 4-20 mA HART, 16 channels

DI (Plus) 24V DC, Dry Contact, 32 channels

DO (Plus) 24V DC, High-Side, 32 channels

The following I/O cards are supported in simplex format  to meet your field wiring needs.

AI Isolated, 4 channels

RTD, 8-channels

Thermocouple, 8 channels

Millivolt, 8 channels

DI, High Density, 32 channels

DI 24V DC Isolated, 8 channels

Multi-Function, 4 channels (Isolated DI)

Sequence of Event, 16 channels (DI 24 V DC)

DI 120V AC Low Side Detection, 8 channels

DI 120V AC Isolated, 8 channels

DO 24V DC Isolated, 8 channels

DO 120/230V AC High-Side, 8 channels

DO 120/230 Isolated, 8 channels

Emerson DeltaV™ M-series Traditional I/O

Decreases capital equipment costs

Full system modularity: The Traditional I/O subsystem was designed with your investment in mind. All components are fully modular and may be installable under power. You add I/O interface carriers and I/O interfaces in groups of 4. 8. 16.or 32 channels as you need them. The modular design enables you to purchase the exact amount of I/O cards, 8-wide or 4-wide carriers, power/ controllers, and 2-wide carriers you need and add more DeltaV I/O as your system grows.

Reduced system footprint: The DeltaV system’s state-of-the- art form factor design of the I/O components enables you to mount the I/O interface carrier in a junction box in the field  so you significantly reduce the footprint of your equipment  and increase valuable control room space for other uses.

Installation: Save on wiring expenses by installing Classic Instrumentation in the field, near the actual field devices.

Mounting the controller with the I/O further reduces your wiring expenditures by eliminating the need for long runs  of multi-cores. The integrated design of the Traditional I/O subsystem can eliminate the need for marshalling panels.

This saves you even more in your total capital costs.

The provision of in-line fuses and bussed power saves  on installation costs compared with external fuses and  power distribution.

Decreases installation time and expense

Plug-and-play installation saves money: All Traditional I/O components plug into the I/O interface carrier. You can install the I/O interface carriers to manage anticipated growth and postpone the I/O interfaces until you’re ready to install your additional field devices.

Phased installation saves time: As soon as you mount the I/O interface carrier, you’re ready to begin installing the field devices. I/O terminal blocks plug directly onto the I/O interface carrier. There is no need to have the I/O cards installed.

Keys: Traditional I/O interfaces and terminal blocks have  I/O function keys. These keys ensure that the correct I/O  card is always plugged into the corresponding terminal block.

It’s incredibly easy to use and gives you time to do more.

Emerson Ovation™ Controller Model OCR3000

Features 

– Quad-processor system-on-chip architecture 

– Supports parallel scanning of 16 input/output branches 

– Single-module solution for Ovation controllers and I/O interfaces 

– Supports controller and network redundancy 

– Compatible with all Ovation I/O modules 

– Compatible with OCR1100 controller applications 

– Copper-based and small form-factor pluggable (SFP) Ethernet connectivity 

– Integrated backplane communication between primary and backup controllers 

– Cryptographic signing of all controller firmware files 

– Embedded communication protocol drivers provide connectivity to third-party devices without additional hardware 

– Optional configuration with Ovation standalone controller software toolkit 

– CE-marked 

– IEC 61131-2 compliant

About Emerson 

Emerson’s Ovation™ Distributed Control System is known for providing precision control with superior performance.

Ovation controllers are designed for mission-critical operations in power and water/wastewater applications.

The OCR3000 model in the Ovation controller family is the successor to the Ovation OCR1100 controller.

The OCR3000 integrates the processor and IOIC module into a single module.

The Ovation OCR3000 controller provides up to 16 local I/O interfaces.

The I/O interfaces are identical to all previous models of Ovation OCR controllers.

The OCR3000 controller scans all 16 I/O branches in parallel, resulting in significant performance improvements.

The OCR3000 can be run as a standalone application when used with the standalone Controller Software Toolkit software.

The OCR3000 can be run as a stand-alone stand-alone application, eliminating the need to create a traditional Ovation network and database.

Search for products

Back to Top
Product has been added to your cart