Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Emerson DeltaV™ Smart Switches Accessing the Console

Accessing the Console.

Secure Shell (SSH) and serial connections are provided using a USB-C cable (except for the RM2040).

The Advanced Configuration menu includes a handful of settings that allow you to customise

the switch for your specific use case while conforming to the requirements of the DeltaV Regional Control Network.

SSH communications provide a secure connection to the switch console.

Encryption in SSH communications provides additional security for switch operation

and maintenance by protecting user credentials and preventing interception.

Full range of switch hardware configurations.

The new generation of DeltaV network switches offers a wide range of hardware solutions.

From 30-port rackmount units to ffxed-port DIN-rail switches,

DeltaV network switches meet a wide range of network requirements.

The extensive line of DeltaV Smart Switches is all you need to implement a complete DeltaV control network.

Emerson provides full support. As an Emerson product,

these DeltaV network switches are fully supported by Emerson when used in a DeltaV network.

Fully supported by Emerson.

As Emerson products,

these DeltaV Network Switches are completely supported

by Emerson when used within the DeltaV network.

You receive full technical support from our Global Service

Center, warranty support, product support, and education —

all from Emerson.

Emerson DeltaV™ Smart Switches Plug and Play Installation

Plug and Play Installation.

The new generation of DeltaV Smart Switches feature a

DeltaV-compatible setup that installs out of the box into a compatible DeltaV network.

They require no user configuration to fully support DeltaV network communications.

NDCC ensures that the configuration of all Smart Switches on the network remains consistent,

so you never have to worry about misconfigurations affecting network performance.

Plug and Play requires that any existing switch or network device be configured for 100/1000 full-duplex communication or auto-negotiation.

Auto-lock prevents unauthorised network connections.

Disabling unused network connections is a security “best practice” that helps you comply with factory security policies.

With the switch’s built-in one-click lockout feature, you simply click a button in the DeltaV Network Appliance Command Centre application to

to automatically lock all unused network ports on your system. Easily protect your network from intrusion.

The port locking algorithm has been enhanced to allow locking of multiple daisy-chained DeltaV nodes,

as well as detection of new nodes within dynamically determined uplink ports.

You can also configure the switch to ignore lockdown commands on specific switch ports if the application requires it.

For example, a port connected to a virtualised host server to allow DeltaV VMs to move between hosts.

Emerson DeltaV™ Smart Switches

Improved performance.

The switching ASICs used in these new products offer new capabilities

such as increased network buffers, the ability to process/forward/filter packets

based on more L2 address information such as IP addresses, UDP or TCP ports, and a non-blocking

architecture.

and non-blocking architecture, in addition to more powerful CPUs for control plane and management

operations.

Plug and Play Installation.

The new generation of DeltaV Smart Switches feature a

DeltaV-compatible setup that installs out of the box into a compatible DeltaV network.

They require no user configuration to fully support DeltaV network communications.

NDCC ensures that the configuration of all Smart Switches on the network remains consistent,

so you never have to worry about misconfigurations affecting network performance.

Plug and Play requires that any existing switch or network device be configured for 100/1000 full-duplex

communication or auto-negotiation.

Emerson KJ4002X1-BE1 Top Extender Cable Assembly

Removal and Insertion

This unit cannot be removed or inserted with system

power energized.

Power must be de-energized before disconnecting

any carriers or LocalBus Extender cables.

This product must not be unplugged unless either

the system has been de-energized or the area is

known to be safe. No combination of I/O carriers and

LocalBus Extenders must exceed a length of 6.5

meters. Interconnecting cable between enclosures

must be in conduit.

Maintenance and Adjustment

This unit contains no user serviceable parts and

should not be disassembled for any reason.

Calibration is not required.

Emerson BoarD SIzE PMCspan PMC Expansion Mezzanine

BoarD SIzE

Height:  233.4 mm (9.2 in.)

Depth:  160.0 mm (6.3 in.)

Front Panel Height:  261.8 mm (10.3 in.)

Width:  19.8 mm (0.8 in.)

ElECTroMagnETIC CoMPaTIBIlITy (EMC)

Intended for use in systems meeting the following

regulations:

U.S.: FCC Part 15. Subpart B, Class B c

Canada: ICES-003. Class B c

This product was tested in a representative system to

the following standards:

CE Mark per European EMC Directive 89/336/EEC  c

with Amendments; Emissions: EN55022 Class B;

Immunity: EN55024

SaFETy

All printed wiring boards (PWBs) are manufactured with

a flammability rating of 94V-0 by UL recognized manufacturers.

Emerson Specifications PMCspan PMC Expansion Mezzanine

Specifications

ForM FaCTor

Single-slot 6U VMEbus format

PCI-To-PCI InTErFaCE

Controller:  PLX6150 PCI-to-PCI interface bridge

Address/Data:  A32/D32

PCI Bus Clock:  33 MHz

Signaling:  5V

Mating Connector on Host Board:  114-pin PCI

Expansion Connector; still allows use of host CPU’s

original PMCs

Compliance:  PCI Local Bus Specification, Revision 2.1

IEEE P1386.1 PCI MEzzanInE CarD SloTS

Address/Data:  A32/D32. PMC PN1. PN2. PN4

connectors

PCI Bus Clock:  33 MHz

Signaling:  5V

Power:  +3.3V, +5V, ±12V, 7.5 watts max. per PMC

Module Types:  Two single-wide or one double-

wide, front- panel or P2 I/O

P2 PMC I/O:  64 I/O signals from first PMC routed

to VMEbus P2 connector

PowEr rEquIrEMEnTS (no PMCS InSTallED)

Power:    +5V @ 0.44 ampere (max.)

+12V @ 0 ampere (max.)

–12V @ 0 ampere (max.)

Emerson PMCspan PMC Expansion Mezzanine Details

PMCspan Details

CarrIEr BoarDS

Emerson offers a full line of PowerPC® microprocessor

based VME products which can be custom configured

for specific applications via on-board PMC slots. The

PMCspan expands this capability to further increase

customizing alternatives. It is compatible with Emerson’s

PowerPlus VME series. For further information on

these host CPUs, contact your local sales representative.

ProDuCT oFFErIng

In order to support the increased PCI bus loading

associated with additional PMCs, PMCspan uses the

PLX6150. This PCI-to-PCI interface bridge supports a

32-bit primary bus interface and a 32-bit secondary

bus interface. PMCspan mates directly with the host

CPU via the separate PCI expansion connector.

When the maximum of two PMCspan modules are stacked

together, the top board does not require a second PCI

to-PCI interface bridge. Software views this secondary

module as an extension to the primary PMCspan.

Emerson PMCspan PMC Expansion Mezzanine

The PMCspan board provides VMEbus processor

modules with greater expansion capabilities

• Single-slot 6U VMEbus format

• PLX6150 PCI-to-PCI interface bridge

• Support for two single-wide or one double-wide PCI Mezzanine

• Card (PMC) per PMCspan

• Stacking capability

• Front-panel and/or P2 I/O

• Compliant with PCI local bus specification (revision 2.1)

• Injector/ejector handles per VME64 extensions

• Compatible with Emerson’s PowerPlus VME series

The Emerson Network Power PMCspan board allows users to customize their exact I/O

requirements with Emerson’s VME-based CPU modules designed around the PowerPlus architecture.

When a PMCspan board is coupled with an Emerson processor module, the system

provides up to six PCI Mezzanine Cards (PMCs), more expansion capability than any

other VME-bus processor module. Each PMCspan board supports either two single

wide or one double-wide PMC. By stacking PMCspan boards onto a processor module,

a total of four additional single-wide PMCs can be added to Emerson’s compute

engines – either today or as future application growth demands.

The PMCspan is a standard 6U single-slot VMEbus module that links to its host board

via a PCI expansion connector. It supports both front panel and P2 I/O access for customer supplied

PMCs.

Prosoft AN-X2-ABRIO-EIPSCN Remote I/O to Ethernet/IP Scanner Module Package Contents

Package Contents

• AN-X2-ABRIO module

• microSD to SD card adapter

• CD containing software and documentation

• rubber feet for desktop use

Using the MicroSD Card

The AN-X2 microSD card stores configuration data and firmware.

The are no restrictions on the size or speed of the card. The format must be FAT-16 or

FAT-32.

An adapter is provided so you can insert the microSD card in an SD slot in your

computer.

The card must be present while the AN-X2 is running.

WARNING!

Do not remove the card while the AN-X2 is powered on!

If the AN-X2 is inaccessible from Ethernet because of its settings, you can remove the

card and edit the file config.txt. Refer to page 12 for details.

Reinsert the card in the slot at the back of the AN-X2. with the pins facing up.

WARNING!

If you remove the card to edit the configuration file, push the card in

straight or the card might fall inside the case and you will have to

disassemble the AN-X2 to retrieve it .

Emerson DeltaV SIS™ Safety Network Components GSN Hardware NextGen

NextGen DeltaV SIS Smart Switches

The DeltaV SIS Smart switches are “built-for-purpose” switches with DeltaV SIS specific software and features to make them

plug-and-play in the safety network.

DeltaV SIS Smart Switches require no configuration to function on the safety network.

DeltaV SIS NextGen Smart Switches and the legacy DeltaV SIS Smart Switches are the only supported switch to be used

within the LSN and GSN. DeltaV SIS Smart Switches are different than DeltaV Smart switches (non-SIS) and are not interchangeable.

There is no limit for the number of LSNBs subscribing to

information from the GSN. Prior to v14.LTS, only one domain

was supported within the GSN, starting v14.LTS and later,

up to 16 domains are supported within the GSN. Refer to

Books Online for more information about system capacities.

Only DeltaV SIS Smart Switches are supported on the GSN.

The GSN requires DeltaV SIS NextGen Smart Switches or the

legacy DeltaV SIS Smart Switches with software release 4.2.14 or greater.

The GSN is certified according to the concept of black channel

per IEC61508-2. Therefore, the GSN hardware components

are considered as an interference free hardware component of the SIS.

Search for products

Back to Top
Product has been added to your cart