Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Emerson PACSystemsTM RX3i I/O Provides High Performance and Advanced Diagnostics

The PACSystems RX3i series offers advanced diagnostics and high-performance I/O.

With its modular design and multiple expansion options, the RX3i is the perfect I/O solution for process, hybrid and discrete applications.

Modularity, High-Speed Performance

The RX3i is a rack-based system with a variety of modules covering digital, analog, and many other specialized I/O types.

These pluggable, hot-swappable modules allow you to customize the right combination of I/O to support a wide range of voltages and current capacities to meet all your application needs.

to meet all your application needs. Regardless of the I/O combination you choose, the RX3i is built on high-speed interfaces that provide fast, stable data transfer.

Highly Scalable

The RX3i’s ability to pair I/Os makes it easy to expand your system. In addition to the inputs/outputs on the mainframe, you can expand locally or remotely by

connect to additional input/output racks. In fact, the RX3i can support as few as 8 I/O points and as many as 32.000 I/O points.

In fact, the RX3i can support as few as 8 I/O points and as many as 32.000 I/O points in a single system.

With 7- to 16-slot backplanes and 1-slot expansion options, you can create the perfect system for your needs.

The Perfect Upgrade Path

Emerson’s RX3i gives you a simple migration path from the 90-30 Series,

90-70 Series, and RX7i Series legacy systems in a fast, hassle-free upgrade program.

RX3i allows you to reuse 90-30 series modules on RX3i backplanes, so you can upgrade your I/O system without having to mess with wiring or buy I/O modules.

As a result, you can upgrade your I/O system without messing with wiring or buying new I/O.

Upgrading to the RX3i improves integrated Ethernet and modern USB communications for serial or memory stick.

With a smaller form factor, greater capacity, and speeds more than 100 times faster than traditional control devices, the RX3i is an easy, cost-effective way to upgrade.

Protect your investment without disruption. Upgrades take hours, not days!

Emerson A6500-RC 16-Channel Output Relay Module

The 16-channel output relay module is designed to provide high reliability for the plant’s most critical rotating machinery.

This monitor is used in conjunction with the AMS 6500 ATG to form a complete API 670 machinery protection monitor.

Applications include steam, gas, compressor and hydraulic turbine machinery.

Any channel of clear, alarm or warning signal can be selected as an input to the 16-channel output relay module.

Configuration is accomplished using Boolean logic, applying time delays and selecting output relays.

Easy-to-use software provides a graphical logic display that graphically guides the user through the configuration.

The AMS 6500 Machinery Health Monitor is an integral part of PlantWeb® and AMS software.

PlantWeb provides operation in conjunction with Ovation® and DeltaV™ process control systems – integrating machinery health.

AMS software provides maintenance personnel with advanced predictive and performance diagnostic tools that enable them to identify machine failures early with confidence and accuracy.

3U-sized, 2-slot plug-in modules cut cabinet space requirements in half compared to traditional 6U cards.

API 670-compliant, hot-swappable modules.

66 inputs, 16 logic networks, 16 relay outputs.

The A6500-RC is a 10TE wide module for use in the A6500-SR rack.

Emerson CSI 6500 Machinery Health Monitor

The CSI 6500 Equipment Condition Monitoring System is fully compliant with API 670 and is designed to protect and monitor critical rotating machinery.

Special features of the system include the ability to integrate data from protection functions into DeltaV and Ovation process automation systems in three simple steps;

Transient analysis with real-time display, logging, pause and playback; and superior PeakVue processing for early detection of bearing and gear damage.

Subrack Configuration:

– The 19″ subrack is used only for the 6 U version of the protection function and the standard 3 U version of the protection function.

– The 19″ subrack is used only for the forecasting function and has a mounting height of 6 U with front or rear sensor connection terminals.

A compact version with a mounting width of 7.5″ is also available.

– Only the 19″/6 U subrack is available for combined protection and forecasting functions.

n The machine monitoring function is fully compliant with API 670.

n Standard 19″/6 U subrack for cabinet mounting

n System design ensures that no more than two channels are affected in the event of a card failure; cards can be replaced during operation

n Internal clock synchronized to the system master clock

n Redundant ModBus connections, TCP or serial connections for integrating the Protection Monitor into third-party control systems.

Emerson CSI 6500 ATG Protection System

Does your budget need more bang for your buck?

What if you could get the benefits of prediction at the cost of protecting your systems? Predictive Intelligence is a key component in improving the availability and reliability of plant assets.

So getting predictive data from your protection system is an important step in understanding and improving the health of your assets.

Emerson’s CSI 6500 ATG protection system features a multifunction card that can be easily reconfigured to take a variety of measurements, including the data needed to provide predictive intelligence.

Predictive Capabilities

Emerson’s CSI 6500 ATG is a standalone machinery protection solution that also allows users to cost-effectively and predictively monitor critical assets with the same system.

Predictive intelligence is key to improving availability and reliability.

The CSI 6500 ATG comes with four reconfigurable cards that capture all required TSI measurements, including predictive data measurements such as the following:

Relative shaft vibration

Absolute shaft vibration

Shell vibration electrodynamic

Shell vibration piezoelectric

Relative displacement

Thrust position

Shell expansion/valve position

Average rod drop

Relative Vibration Hydrodynamic

Hydraulic absolute vibration

Eccentricity

Rotation speed

Key

Temperature

Process Parameters

Emerson A6370 Overspeed Protection Monitor

Emerson A6370 Монитор защиты от превышения скорости

A6370 Overspeed Protection Monitor

The A6370 monitor is part of the AMS 6300 SIS overspeed protection system and is mounted in a 19-inch rack (84HP wide, 3RU high) with the A6371 system backplane.

An AMS 6300 SIS consists of three protection monitors (A6370) and one backplane (A6371).

The system is designed for eddy current sensors, Hall element sensors, and magnetic (VR) sensors.

Sensor Supply Voltage

Nominal Supply Voltage -24.5 V ±1.5 V DC Short-Circuit Proof, Galvanic Isolation

Maximum Current Current 35 mA

Signal Inputs, Eddy Current and Hall Element Sensors

Input signal voltage range 0 V to 26 V (+/-) Reverse polarity protection

Limit range ± 48 V

Frequency range 0 to 20 kHz

Typical input resistance 100 kΩ

Signal input, magnetic (VR) sensors

Input signal voltage range min. 1 Vpp, max. 30 V RMS

Frequency range 0 to 20 kHz

Typical input resistance 18 kΩ

Digital inputs (backplane)

Number of inputs 4 (galvanically isolated All digital inputs All digital inputs)

(test value 1. test value 2. enable test value, reset latch)

Logic low 0 V to 5 V

Logic high 13 V to 31 V, open circuit

Typical Input Resistance 6.8 kΩ

Current Outputs (Backplane)

Number of Outputs 2 Galvanically isolated, common ground

Range 0/4 to 20 mA or 20 to 4/0 mA

Accuracy ±1% of full scale

Maximum load <500 Ω

Maximum output current Output current 20 mA

Digital outputs (backplane)

Number of outputs 7 (short-circuit proof) Outputs 1 to 6. channel Ok (COK)

Logic low < 100 mV

Logic high -2 V System supply voltage

Maximum current Current 25 mA

Pulse outputs (backplane)

Number of outputs 3 Open collector-emitter, current limited, galvanically isolated

Emerson Ovation™ Power System (5X00785G09)

Features

Redundant power configurations, each with separate external wide range AC or DC feeds

Separate primary and auxiliary power supplies in both primary and auxiliary configurations

Dual wide-range input capability

Diode auction feed

High efficiency power supplies

Modular fanless system

Redundant feeds to each controller chassis and I/O module

Continuous system monitoring

OVERVIEW

Emerson has developed a DIN-rail mounted power supply that includes four modular fanless power systems to provide reliable and stable power to Ovation™ controllers and I/O modules.

The Ovation controller power supply systems are configured in redundant configurations, each with a separate external wide-range AC and/or DC input feed.

Dual diode auction 24 VDC outputs are used to power each controller chassis and associated I/O modules, as well as to power loop and contact wetting for the I/O modules.

A 48 VDC auxiliary power supply is available for loop and contact wetting if required.

Two separate output schemes are available:

24 VDC / 10 A / 240 W main power and 24 VDC / 10 A / 240 W auxiliary power.

24 VDC / 20 A / 480 W main power supply and 24 VDC / 20 A / 480 W auxiliary power supply.

Benefits

Benefits of Ovation power solutions include

Separate primary and auxiliary power supplies are easy to replace

No cooling fan required, greatly reducing the risk of failure

Diode auction feed ensures continuous power

New design improves efficiency, reduces heat generation and extends equipment life expectancy

Dual input (AC and DC) capability reduces spare parts

Hot-swappable power supplies enable in-line replacement

Quick installation of power supplies minimizes downtime and lost production

Power factor correction reduces power consumption

10 Amp Power Solutions

10 Amp power supply options include

Redundant Power Configuration (Primary and Auxiliary) includes separate 10 Amp Primary and Auxiliary power supplies supporting multiple input voltages (85-264 VAC @ 43-67 Hz or 90-375 VDC) with 240 W output power.

Emerson 1066 Liquid Analysis Fieldbus pH/ORP Transmitter

Features and Applications

The Model 1066 Fieldbus Transmitter supports continuous measurement of one liquid analysis input.

It is designed for easy internal access and wiring connections.

Analytical inputs: pH and ORP sensors with or without Rosemount Analytical preamplifiers, and Rosemount Analytical smart pH sensors.

Large Display: High-contrast LCD displays real-time measurement readings in large numbers and up to four additional variables or diagnostic parameters.

Digital Communications: Fieldbus ITK 6 Menus: Menu screens for calibration and programming are simple and intuitive. Plain language prompts and “help” screens guide the user through the steps.

All menu screens are available in eight languages. Real-time process values are displayed during programming and calibration.

Troubleshooting and Warning Help Screens: Troubleshooting and warning information is included in the Help screens to provide the user with helpful troubleshooting tips. These screen instructions are intuitive and easy to use.

Diagnostics: The transmitter continuously monitors itself and the sensors for problems. On-screen display banners alert technicians to faults and/or warning conditions.

Languages: Emerson extends its global reach by offering eight languages: English, French, German, Italian, Spanish, Portuguese, Chinese, and Russian.

Input Damping: Automatically enabled to suppress noisy process readings.

Smart Enable pH: Rosemount Analytical SMART pH feature eliminates the need for field calibration of pH probes by automatically uploading calibration data and history.

Automatic Temperature Compensation: pH measurements require temperature compensation. the 1066 will automatically recognize the sensor’s built-in Pt100 or Pt1000 RTD, or the temperature of an on-bus temperature measurement can be linked to the 1066 and used for temperature compensation.

Emerson VersaPoint I/O Input/Output Modules

VersaPoint I/O

The VersaPoint™ Distributed I/O System offers optimal compactness and flexibility while allowing users to install the right amount of I/O for each application.

Allows users to install the right amount of I/O for each application.

VersaPoint adheres to open communication standards, including Ethernet, Profibus-DP™, and DeviceNet™, for easy connection to a wide range of PLCs, DCSs, and PC-based control systems.

It is suitable for packaging and material handling applications as well as monitoring and data acquisition.

Superior Flexibility

VersaPoint’s modular structure allows it to be easily adapted to a wide range of applications. It accommodates a range of discrete and analog I/O modules, from 1-point to 16-point densities.

VersaPoint also supports a wide range of specialized modules, from RTD and thermocouple inputs to positioning and counting modules, virtually combining intelligent automation with the simplicity of endpoint technology.

Compact size

VersaPoint saves valuable control panel space by eliminating the need to plug in terminals.

Its compact and versatile design saves up to 50% of space compared to conventional systems.

Reduced Installation Time

Installing VersaPoint couldn’t be quicker: I/O modules can be quickly and securely fastened to the DIN rail.

Thanks to the integrated I/O terminals and internal power bus, VersaPoint reduces wiring by up to 80%.

Cost-effective solution

Fast installation, reduced cabling, and more efficient use of cabinet space all make VersaPoint a great value.

Cost savings continue during operation. Extensive built-in diagnostics make identifying faults routine, maximizing uptime.

Emerson DeltaV™ M-Series Product Description

I/O Cards

A variety of analog and discrete I/O cards are available to meet your specific requirements.

The following cards support simplex or redundant installation:

AI 4-20 mA HART 8 channels

AO-4-20 mA HART 8 channels

DI, 24V DC Dry Contact, 8 channels

DO 24V DC High-Side, 8 channels

AI (Plus) 4-20 mA HART, 16 channels

AO (Plus) 4-20 mA HART, 16 channels

DI (Plus) 24V DC, Dry Contact, 32 channels

DO (Plus) 24V DC, High-Side, 32 channels

The following I/O cards are supported in simplex format  to meet your field wiring needs.

AI Isolated, 4 channels

RTD, 8-channels

Thermocouple, 8 channels

Millivolt, 8 channels

DI, High Density, 32 channels

DI 24V DC Isolated, 8 channels

Multi-Function, 4 channels (Isolated DI)

Sequence of Event, 16 channels (DI 24 V DC)

DI 120V AC Low Side Detection, 8 channels

DI 120V AC Isolated, 8 channels

DO 24V DC Isolated, 8 channels

DO 120/230V AC High-Side, 8 channels

DO 120/230 Isolated, 8 channels

Emerson DeltaV™ M-series Traditional I/O

Decreases capital equipment costs

Full system modularity: The Traditional I/O subsystem was designed with your investment in mind. All components are fully modular and may be installable under power. You add I/O interface carriers and I/O interfaces in groups of 4. 8. 16.or 32 channels as you need them. The modular design enables you to purchase the exact amount of I/O cards, 8-wide or 4-wide carriers, power/ controllers, and 2-wide carriers you need and add more DeltaV I/O as your system grows.

Reduced system footprint: The DeltaV system’s state-of-the- art form factor design of the I/O components enables you to mount the I/O interface carrier in a junction box in the field  so you significantly reduce the footprint of your equipment  and increase valuable control room space for other uses.

Installation: Save on wiring expenses by installing Classic Instrumentation in the field, near the actual field devices.

Mounting the controller with the I/O further reduces your wiring expenditures by eliminating the need for long runs  of multi-cores. The integrated design of the Traditional I/O subsystem can eliminate the need for marshalling panels.

This saves you even more in your total capital costs.

The provision of in-line fuses and bussed power saves  on installation costs compared with external fuses and  power distribution.

Decreases installation time and expense

Plug-and-play installation saves money: All Traditional I/O components plug into the I/O interface carrier. You can install the I/O interface carriers to manage anticipated growth and postpone the I/O interfaces until you’re ready to install your additional field devices.

Phased installation saves time: As soon as you mount the I/O interface carrier, you’re ready to begin installing the field devices. I/O terminal blocks plug directly onto the I/O interface carrier. There is no need to have the I/O cards installed.

Keys: Traditional I/O interfaces and terminal blocks have  I/O function keys. These keys ensure that the correct I/O  card is always plugged into the corresponding terminal block.

It’s incredibly easy to use and gives you time to do more.

Search for products

Back to Top
Product has been added to your cart