Woodward GS-Series (GS40/50) Fuel Flow
Fuel Flow
Gas fuel flow is normally achieved by the accurate scheduling of the metering valve port area, based on
values for gas properties, operating pressures, and temperature. The GS-Series valve is factory calibrated
under flow
and pressure conditions to provide an accurate valve metering to the input demand signal. Flow
equations for the valves are located in the O&M manual. These can be used to set up the valve for any
site-specific conditions.
Port Sizes
The GS-Series is available with five different port sizes to optimize valve performance for various flow and
pressure drop requirements. Standard port effective area sizes are:
GS40
• 0.30 in² (193.5 mm²)
• 0.75 in² (483.9 mm²)
GS50
• 1.0 in² (645.2 mm²)
• 1.5 in² (967.7 mm²)
• 2.0 in² (1290.3 mm²)
The standard metering ports are contoured to provide approximately square law relationships between
commanded position and effective area.