Welcome to the official website of CNIACS Automation Technology Co., Ltd!

CTI 2596-8 8 Point DC Discrete Output Module

Description

The 2596-8 8 Point DC Discrete Output Module

provides eight sourcing fused outputs from the CTI

2500 Series® or Simatic® 505 I/O base. The module

utilizes solid-state output circuits to switch on or off

external devices such as pilot lamps, motor starters,

or solenoids. The 2596-8 is designed to switch

externally supplied 11-125 VDC.

Features

• 8  DC output points

• Replaces Siemens® 505-4508. -4708

• 3000 VDC group-to-group isolation

• 2100 VDC channel-to-backplane isolation

• Isolation in groups of two

• Wide 11-125 VDC output range

• 2.0 Amps per output

• 16 Amps total module output

• Individually sourcing fused outputs

• Single-wide module

CTI The 2595 may operate as a 16 Bit Word Output Module

Word and Discrete Mode

The 2595 may operate as a 16 Bit Word Output Module or as a 16

Discrete Output Module. By setting JP1 in Word Mode and using Work

shop to configure I/O the 2585 will look like a standard WX input mod

ule; for example WY1-WY8.

NOTE: The 2595 will be mapped as the first WY address (i.e. WY1). In

Word Mode Channel 1 corresponds to bit 16 or LSB and Channel 16

corresponds to Bit 1 or MSB.

In the example Figure 2. the 16-point TTL output module is inserted in

slot 1 in I/O base 0 and configured as a DISCRETE Output module

using JP1. In the example below  data appears as 16 “Y” locations start

ing at “Y1”. For your particular module, look in the chart for the num

ber corresponding to the slot occupied by the module. If bit locations

appear on this line, then the module is registered in the PLC memory

and the module is ready for operation.

CTI 2595 Specifications

Specifications

Inputs per module: 16 (2 outputs per common)

Isolation:

500 VDC group-to-group

1500 VDC channel-to-backplane

1500 VDC channel-to-backplane

Output Drive Capabilities:

High (VOH) (minimum) = 4.5 V @ 500 μA

Low (VOL) (maximum) = 0.4 V @ 30 mA

Rise/Fall Time = 1 μSec

Outputs are true “low” when energized

Sink Current: (maximum per output) 50 mA

PLC Reporting: X or WX (jumper selectable)

Wire gauge: 14-22 AWG removable connectors

Backplane power: 2 Watts max

Module size: Single-wide

Blown fuse indication: Front panel LED

Shipping weight:1 lb. (0.45 Kg)

Additional Product Information:

On CTI’s Website you find will links to the 2500

Series  Std Environmental Specifications and the UL

Agency Certificates of Compliance .

CTI The 2595 16-Point TTL Output Module

Description

The 2595 16-Point TTL Output Module provides

sixteen TTL or CMOS compatible outputs to the CTI

2500 SeriesTM or Simatic® 505 I/O base. The

module is designed to respond to standard output

instructions. With the 2595. the PLC is capable of

providing signals to a variety of field devices

including lab instrumentation, BCD message

displays, video terminals, board level devices, and

low current annunciator panels. With an external pull

up resistor, the 2595 can interface to 24 VDC control

systems and other instrumentation. The module can

drive up to 16 CMOS or TTL loads per output.

Features

• CTI 2500 SeriesTM or Simatic® 505 Series I/O

base format

• 500V channel-to-channel isolation

• 1500 VDC channel-to-PLC backplane isolation

• Drive BCD message displays and video terminals

• High speed TTL interface to board level devices

• Interface to 5 to 24 VDC control systems and

instrumentation

• Operates as a discrete or 16 bit word output

CTI 2590-EF and 2591-EF Specifications

Specifications

Outputs: 16

Output voltage: 20 to 132 VAC

Output source current per circuit:  2.0A max

Minimum current: 40 mA per circuit

Non-repetitive surge current: 80 Amps (1 cycle)

“OFF” state leakage: 1 mA maximum @ 25°C

Turn ON or OFF time: 1 AC cycle

Total module output current: 32 Amps max

Fuses: 16. 3 Amp, 250 V, Type Littlefuse

#2173.15. Bussman GMA# GMA-3A,

CTI Part #80-65 (field replaceable)

Specifications 2591-EF

Outputs: 16

Output voltage: 11 to 146 VDC

Output source current per circuit:  1.5A max

Maximum surge current:3 Amps for 15 seconds

“ON” state voltage drop:0.3 V @ 1.5 Amps

“OFF” state leakage current:125 µA @ 146 VDC

Turn ON time:0.5 mSec (nominal)

Turn OFF time: 1.5 mSec (nominal)

Total module output current: 24 Amps max

Fuses: 16. 1.6 Amp, 250 V, Schurter #034.2518

CTI Part #80-79 (field replaceable)

Specifications Common to Both

Isolation: 1500 VDC channel-to-channel

1500 VDC channel-to-backplane

Connector: Removable

Wire gauge:14-22 AWG

Backplane power:2.5 watts max

Module size:  Double wide

Blown fuse indication: Front panel LED (per channel)

Blown fuse reporting:

Reported to PLC as X input per channel (jumper selectable)

Operating temperature: 0° to 60°C (32° to 140°F)

Storage temperature:-40° to 85°C (-40° to 185°F)

Humidity, relative:5% to 95% (non-condensing)

Agency approvals:  UL, UL Canada, FM (Class, Div 2)

CTI 2590-EF and 2591-EF 16-Point Discrete Output Modules

Description

The  2590-EF and 2591-EF 16-Point Discrete Output Modules provide sixteen

isolated outputs from the CTI 2500 SeriesTM or Simatic®  505 I/O base with

front panel accessible fuses. The modules use solid-state output circuits to

switch on or off external devices such as pilot lamps, motor starters,

or solenoids. The  2590-EF is designed to switch externally supplied 20

to 132 VAC and the 2591-EF is designed to switch externally supplied 11 to

146 VDC.

For both modules, the internal logic signals are isolated from the external

outputs to 1500 VDC.

Features

•Supports sourcing and sinking applications

•Front panel accessible fuses for easier maintenance

•2A per output 2590-EF (no derating) 1.5 A per output 2591-EF (no derating)

•Blown fuse reporting directly to PLC for each channel

•Logs in as 16Y or 16X/16Y (jumper selectable)

• Isolated 1500 VDC channel-to-channel 2590-EF

CTI The 2590-A is capable of logging in as a 16Y or a 16X/16y

Module Configuration

The 2590-A is capable of logging in as a 16Y or a 16X/16y.

Changing the addressing of the module is done by moving a

jumper located near the rear backplane connector as shown in

Figure 2 below. In Figure 2. the 2590-A module is inserted in slot

1 in the I/O base 0. Data appears as 16 “Y” locations starting at

“Y1”. The 2590-A ships with a login of 16Y. In this configura

tion blown fuse reporting is disabled. By moving the jumper to

the REPORTS 16X INPUTS the module logs in as a 16X/16Y.

The X addresses are used to report the Blown Fuse Indication

and the 16Y addresses are used as any other normal output

would be used.

CTI 2590-A Specifications

Specifications

Outputs: 16

Logon: 16Y/16X or 16Y

Isolation:

1500 VDC channel-to-channel

1500 VDC channel-to-backplane

Blown fuse reporting per channel:

Reported to the PLC as an X input (jumper selectable)

Output voltage: 20 to 132 VAC

Output source current per circuit: 2.0 A max

“OFF” state leakage: 1mA max @ 25°C

Turn ON or OFF time: 1/2 AC cycle

Non-repetitive surge current: 80 Amps for 1 cycle

Total module output current: 32 Amps

Connector: Removable 40 Pin Connector

(ordered separately CTI Part # 2500-40F)

Wire gauge: 14 to 22 AWG

Backplane power: 2.5 watts max

Module size: Single wide

Fuses: 16. 3 Amp, 250V Type Littlefuse #2173.15

or Bussman GMA #GMA-3A or CTI Part Number

#80-65(Field Replaceable).

Shipping Weight:  1.5 lbs (0.68Kg)

Additional Product Information:

On CTI’s Website you will find links to the 2500 Series

Std Environmental Specifications and the UL Agency

Certificates of Compliance

CTI 2590-A 16-Point Isolated Discrete Output Module

Description

The 2590-A 16-point Isolated Discrete Output Module

provides sixteen discrete isolated outputs from the CTI

2500 Series®or Simatic® 505 I/O base. The module

uses solid- state output circuits to switch on or off ex

ternal devices such as pilot lamps, motor starters, or

solenoids. The 2590-A is designed to switch externally

supplied 20 to 132 VAC. The internal logic signals are

isolated from the external outputs to 1500 VDC.

Features

• CTI 2500 Series®  base format

• 2.0 Amps per output (no derating)

• Isolated 1500 VDC channel-to-channel

• Blown fuse reporting (per channel) to the PLC

• Blown fuse indicator

• Logs in as a 16Y or 16X/16Y (jumper selectable)

• Individual fuse for each output channel

• Single-wide module

CTI 2589-B Specifications

Specifications

Inputs per Module: 8. 16 or 32

Classic

Isolation: 1500 VDC channel-to-backplane

1500 VDC group-to-group

Input Voltage:

Range Setting

12/24V range

48V range

110V range

220VAC range

Operating Range

11 – 30 volts

40 – 56 volts

79 – 132 volts

164 – 240 volts

*NOTE: 220V range is AC only

Input Current: AC: 2.1—3.6 mA

DC: 2.5—4.3 mA

Operating Characteristics for Typical Input:

AC Voltage Input:

Turn ON Time:    4.0mS

Turn OFF Time:    15.0mS

DC Voltage Input:

Turn ON Time:    1.0mS

Turn OFF Time:    15.0mS

Connector: 2500-40F Removable Connector (sold

separately)

Wire Gauge: 14-22 AWG

Backplane Power: 3.6 Watts max.

Module Size:  Single-wide

Operating Temperature: 0° to 60°C

(32° to 140°F)

Storage Temperature:  -40° to 85°C

(-40° to 185°F)

Relative Humidity:  5% to 95%

(non-condensing)

Shipping Weight:  1.5lb (0.68 Kg)

Voltage Range Selection Jumpers

The 2589-B will handle a wide range of AC and DC signals,

and has incorporated the ability to select either 12V/24V, 48V,

110V, or 220V on a per channel basis using jumper selection.

The selections are made individually for each of the 32

channels using jumpers. However, the same voltage range

must be selected for all channels in the same group. The

operating ranges are as follows:

Range Setting

12/24V range

48V range

110V range

220VAC range

Operating Range

11 – 30 volts

40 – 56 volts

79 – 132 volts

164 – 240 volts

* NOTE: 220V range is AC only

Search for products

Back to Top
Product has been added to your cart