Bently Nevada SCOUT220-IS and SCOUT240-IS Portable Features

Hardware Features

l Battery life of 10 hours allows the data

collector to run all day.

l Five year warranty.

l Rugged, water, and dust resistant (IP-65),

drop-tested, with intrinsically safe

variants.

l Easy to carry: lightweight handheld unit,

shoulder strap for data collector, keepers

for sensors.

l Safety breakaways on both shoulder

strap and sensor cables.

l Upgradable industrial handheld

smartphone or tablet.

l Handheld Push-to-Talk(PTT) button is

configured to start measurements

(where available).

l Up to four channel simultaneous

recordings (including on-route).

l SCOUT240 supports Triaxial sensors.

l Up to 12,800 lines of spectral resolution,

80 kHz Fmax.

l Supports accelerometer, velocity,

displacement, and voltage-output

sensors of AC and DC coupling types.

Software Features

l Seamless on-and off-route data

collection.

l Route overview & easy route navigation.

l Fast sensor settling and data collection.

l Patented 6Pack time-saving

measurement type.

l Synchronous sampling, peak demod, and

bump test.

l Coast-down, run-up, and interval

capture support.

l Custom note and numeric data entry.

l Rotor Balancing, dual plane, reports

transferred to System 1.

l Data quality warnings and easy-tounderstand alarm annunciation.

l Supports operator driven reliability (ODR).

l Cross Channel Phase measurement & reports.

Bently Nevada SCOUT220-IS and SCOUT240-IS Portable

Description

SCOUT220IS and SCOUT240IS are intrinsically safe portable data

analyzer solutions designed to monitor machinery conditions in

hazardous environments. Both are rated ATEX Zone 1 / Zone 21

(for gases and non-conductive dust) and CSA Class 1 / Div 1.

These small form-factor, rugged devices take vibration

recordings and upload the collected data for detailed analysis in System 1.

This is a two-part solution. The SCOUT data acquisition module

uses Bluetooth to communicate with a wireless, industrial

handheld device running the S1 Collector app.

Vibration recordings are viewed and stored on the handheld

device. We offer these devices with hazardous area ratings up to

Zone 1/21 & Div 1. The handheld runs the Android OS, so you can

also use it like any smartphone or tablet to take pictures and

video, send text messages, check email, make phone calls, track

your location, create SOS alerts, and run other enterprise apps.

The high performance data acquisition module provides long

battery life, yet is light & rugged. It hangs out-of-the-way on a

shoulder strap, allowing you to focus on your job and move

safely between machines. The SCOUT220IS can sample two

sensor channels simultaneously, while the SCOUT240IS supports

up to four channels. Both also support tachometer or Keyphasor

triggering. These data acquisition modules provides up to ten

hours of continuous use, while supporting an Fmax up to 80 kHz

and 12,800 lines of spectral resolution. Both models are rated

IECEx/ATEX Zone 0 / 20 (for gases and non-conductive dust) and

CSA Class 1 / Div 1.

Bently Nevada SCOUT200 series High performance data acquisition

High performance data acquisition

Unlike most products on the market,

the intrinsically safe SCOUT devices

retain the same high performance

and long battery life as their non-rated COMMTEST brethren.

Ten hours of continuous use, while supporting up to: 80

kHz Fmax, 12,800 line spectral resolution, 6-Pack super fast

measurements, 4 channel simultaneous sampling, optional

tachometer. And the firmware updates automatically from

the handheld. Amazing!

System 1 software,your plantwide solution

Use System 1* to prepare routes, analyze

data, detect long-term trends, set and

detect alarms. Then synchronize data

with your SCOUT handheld using WiFi, file

transfer, cellular network, or a USB cable. But

System 1 doesn’t stop there, it’s the same powerful package

that’s coupled with a broad range of Bently Nevada condition

monitoring and protection products. One source of the truth,

modern and plantwide.

Bently Nevada SCOUT200 series Flexible handheld options

Flexible handheld options

Choose from multiple handheld devices

to meet your form factor, screen size, and

hazardous rating needs. Update your

handheld at any time, load the System 1

Collector app onto the new device and get collecting.

So easy to carry

Carry the data acquisition module using a

shoulder strap or a belt clip. Sensors mount onto sensor

keepers. Hold the industrial smartphone or tablet in your

hand, on a belt clip, or on a neck strap. So you can focus on

your job and move safely between machines.

Powerful and connected

Vibration recordings are viewed and stored on the handheld

device. It runs the Android OS, so you can use it like any

smartphone or tablet to take pictures and video, send

text messages, check email, make phone calls, track your

location, create SOS alerts, and run other enterprise apps. Try

doing all that on an old school data collector!

Bently Nevada SCOUT200 series

Portable vibration analyzers

These portable data collector solutions record the vibration

of industrial machines, to monitor their condition and

diagnose their faults. The Series includes “SCOUT” models

for use in hazardous areas (explosive atmospheres) and

“COMMTEST” models for less stressful environments. There

are 2-channel and 4-channel versions of each, to suit your

data acquisition and analysis needs.

Designed in and for the 21st century

These two-part solutions utilize the power and

connectivity of modern industrial smartphones

and tablets, paired with a small form factor,

rugged data acquisition module. This gives the

best of both worlds, a fast handheld device full of accessories

and communication options, and a simple durable interface

to sensors on your machines.

CT/VT Modules with Enhanced Diagnostics Internal CT secondary monitoring

After the multiplexer samples analog channels via the sample and hold (S/H) mechanism, samples from all four channels are summed up digitally, using the same equation to get a digital value Sd. The “Mean Square” of the difference between the channels is summed up in the hardware and an equivalent, computed digitally over one protection pass is supplied to the comparator. If the summed squared difference Σ(Sa – Sd)2 is greater than the adaptable per signal level error boundary, then “invalid data” is declared and protection functions using the measured data are momentarily blocked. In addition, if the error keeps repeating, a major self-test diagnostics error message is displayed on the UR. As a result of such failure, the relay’s self-test alarm contact operates and the relay is taken out of service. The relay can be rebooted and if no more failures are detected, it continues to be functional unless a new failure is detected and the relay is again taken out of service. The above analog data integrity check is performed on both analog banks (that is, four currents or four voltages) within each CT/VT input module.

In addition, these modules with enhanced diagnostics include power supply voltage rail monitoring to further monitor hardware health. This is achieved by continuous check of the power supply voltage Vdc against safe operate reference voltage Vref, which ensures that all electronic components of the CT/VT module operate in the safe operating conditions.

Internal CT secondary monitoring

The CT/VT input modules with enhanced diagnostics are monitoring internal CT circuitry integrity. This is done to eliminate relay erroneous operation in case of CT secondary winding failure. The secondary winding of CT is divided into two equal parts with a central tap in the middle. CT current values from both halves of the CT secondary windings are run through a differential amplifier to get a true current sample for the phasor calculations. It also compares between each other by simply summing two samples together. (Note that due to CT central tap, samples have different polarity.) In case that values from different halves of the same CT accumulated over one protection pass per adaptable per signal level do exceed the fixed error boundary, failure is declared and protection is blocked. CT secondary monitoring is performed at all four CT channels (A, B, C, and N) individually at each CT bank.

CT/VT Modules with Enhanced Diagnostics

INTRODUCTION

The performance of a microprocessor-based relay is highly dependent on the performance of the analog channels measurement of the relay, as protection functions operate on these values. The failure of an analog measurement channel, either due to a failure in the external measurement circuit, or due to an internal failure inside a UR CT/VT module, can cause incorrect operation of protection functions. The UR CT/VT modules with Enhanced Diagnostics (module types 8L, 8M, 8N, 8R, 8S, 8V) can detect the failure of an analog channel measurement due to internal failures of the CT/VT module, alarm for failure of the module, and block tripping from any protection function associated with this module. This feature is available when using firmware 5.20 or later within the UR family and therefore field-proven since 2006.

Analog data integrity validation

The CT/VT input modules (8L, 8M, 8N, 8R, 8S, 8V) use an analog data integrity check to verify the performance of the analog measurement channels. This feature uses an additional analog hardware channel that has as its input, an analog sum of Sa = Xa – Xb + Xc + Xn, where X stands for either Voltage or Current phases A, B, C, and N analog inputs, to monitor the integrity of analog data.

ABB Power Supply SA 801F / SA 811F

Features

… Input voltage 115 – 230 VAC (self adjusting), output is elec

trically isolated

… Power supply outputs provide:

SA 801 F: 5 V DC / 5 A and 3.3 V DC / 5 A

SA 811 F: 5 V DC / 5.5 A and 3.3 V DC / 6.5 A

… Enhanced power-fail prediction and shutdown procedures

… LED indication for power supply status and operating

status of the AC 800F

… Short circuit proof, current limited

… 20 ms backup energy for use in the event of primary power

failure, according to NAMUR

Description

The AC 800F modules are supplied with 5 V DC / 5 A and 3.3 V DC / 5 A auxiliary power by the SA 801F or 5 V DC / 5.5 A and 3.3 V DC / 6.5 A by the SA 811F power supply. The power supply has open-circuit, overload and sustained short-circuit protection. The electronically controlled output voltage provides high stability and low residual ripple. In case of power loss ≥5 ms, the power supply module generates a power-fail signal. This signal is used by the CPU module to shut down operations and enter to a safe state. This is required for a controlled restart of the system and the user application when power is restored. The output voltage remains within its tolerance limits for at least another 15 ms. Altogether a mains voltage drop of 20 ms will be managed.

CTI 2500 Series® Compact Programmable Automation Control System-

SIMPLY SEAMLESS

The CTI 2500 Series® Automation System

The 2500 Series® has a proud legacy as one of the world’s premier process control platforms and is

known for its capability, simplicity and reliability. CTI has modernized this legendary product line

with smart enhancements and rich features to create a complete automation solution that helps our

customers run their plants as safely, efficiently and seamlessly as possible.

The BLUE Platform

CTI 2500 Series® products are built on the BLUE PlatformTM — CTI’s seamless systems architecture.

Products built on the BLUE PlatformTM are engineered with a consistent design philosophy, a

common operating system and common communications protocols and interfaces. This approach

ensures interoperability between various components of the system as well as between various

product generations to deliver seamless operational communications and control and maximum

efficiency with minimum process downtime and greatly reduced engineering development time.

Whether you choose Classic, Compact or Slice, the seamless systems architecture of the BLUE

PlatformTM will ensure seamless integration and powerful process control. Please contact us to learn

more.

CTI 2500 Series® Compact Programmable Automation Control System

OVERVIEW

The 2500 Series® Compact PAC System delivers all of

the performance and reliability of the 2500 Series®

Classic System in a significantly smaller form factor.

Featuring the same programming software and

instruction set, and the same communication, remote I/O

and data sharing protocols, the 2500 Series®

common architecture allows Compact System users to get up to

speed quickly using existing tools and diagnostics and to

integrate Compact Series products with other 2500

Series® products easily.

The 2500 Series® Compact System includes a wide

range of digital, analog and specialized I/O modules,

power supplies, and bases. These products work

seamlessly with Classic 2500-Cxxx processors, the new

Compact 2500C-Cxxx processors (coming soon), as well

as Simatic 545 and 555 processors to manage everything

from small discrete control applications to large process

applications with PID loops, alarms, and special

mathematical functions. The CTI approach to automation

emphasizes continuous evolutionary improvement,

compatibility across successive product generations and

operational simplicity to help customers optimize plant

performance at the least possible cost. 