Welcome to the official website of CNIACS Automation Technology Co., Ltd!

MKVI Gas Turbine Control System IS200TBCIH1C Contact Input Terminal Blockv

IS200TBCIH1C Contact Input Terminal Block

The IS200TBCIH1C is an important part of the GE Speedtronic MKVI gas turbine control system and is used as an analog output terminal board.

It helps to generate and distribute the analog output signals that are critical for monitoring and controlling the various devices in the turbine system.

The board is equipped with two long green terminals, each of which can accommodate up to 24 terminals, ensuring efficient connections.

Features such as noise and surge suppression, current loading capability and simplified hardware configuration make it an integral part of the precise control and management of turbine operations.

Specification

Product Type: Terminal Block

Manufacturer: General Electric

Series: MKVI Series

Description: Analog Output Terminal Block

Terminals: Two long green blocks with up to 24 terminals per block

Connections: 6 jack connector ports with 37 female connector points per port

Features:

Terminal Block Design: This IS200TBCIH1C features a rugged rectangular design with two long green terminals that provide ample connectivity for analog output signals.

Connectivity: The board features 6 jack connector ports, each equipped with 37 female connector points for seamless integration with external devices.

Potentiometers: 16 small potentiometers, organized in two rows, provide enhanced control and adjustment capabilities, allowing fine tuning of the output signals.

Noise and Surge Suppression: Filters designed to reduce high frequency noise and suppress surges, ensuring signal integrity and system stability.

Current Load Capability: The first 21 www.cniacs.com outputs are capable of handling 2.5 mA of current per point, and the last three outputs are loaded with 10 mA to meet varying output requirements.

Hardware Configuration: Simplified configuration without hardware setup or jumpers simplifies integration within the Speedtronic MKVI system.

Reliability: Known for its reliability and durability, it ensures consistent performance in demanding turbine control environments.

Compatibility:

The IS200TBCIH1C terminal block is fully compatible and integrated into the Speedtronic MKVI gas turbine control system.

It is terminated via external I/O for use primarily with GE Speedtronic Mark VI series turbine control systems.

The board’s multi-layer PCB design, fitted with SMD components and connectors, ensures compatibility with different system architectures and configurations.

GE’s ongoing revision demonstrates GE’s ongoing efforts to improve compatibility and integration with the Speedtronic MKVI system.

Mark VIe Series IS2020JPDBG01 Power Distribution Boards

Functional Description:

The IS2020JPDBG01 is a power distribution board manufactured and designed by General Electric as part of the Mark VIe series used in GE distributed control systems.

The JPDB board for AC power distribution regulates, monitors, and decentralizes AC power. The module contains two line filters and an IS200JPDB board.

The module contains two independent AC power distribution circuits, each rated at 20 A at 115 or 230 V AC.

The input circuits should be wired in parallel to prevent PPDA alarms when only one AC power source is available.

Each circuit has one fuse output and three fuse and switch branch circuit outputs. the JPDF 125 V DC power distribution module has an optional connection.

The IS200JPDB has status feedback for all fuse circuits and passive supervisory circuits for both AC ranges.

On connector P1 is the supervisory circuitry for connecting cables to the board containing the power supply diagnostic PPDA I/O packages.

Port P2 on the IS200JPDB allows monitoring signals from other power distribution system cards to pass through.

Compatibility:

The JPDE, JPDF, JPDS, and JPDM feedback signal P1 and P2 connections on the IS2020JPDB are compatible, resulting in a PPDA I/O package. The AC input on the JPDF module of the same name can be used with connector JAF2.

Installation:

In the PDM cabinet, the IS2020JPDB module is mounted vertically on a metal rear base. The protective grounding system and the IS2020JPDB sheet metal must be connected.

For the first AC circuit, input power is delivered to www.cniacs.com terminals AC1H (line) and AC1N (neutral), and for the second AC circuit, input power is delivered to AC2H (line) and AC2N (neutral).

There must be a grounded neutral connection on both AC inputs. Follow the documentation for the system’s output circuit connections.

If the distribution system has a PPDA Power Diagnostics I/O package, a 50-pin ribbon cable is required to connect JPDB connection P1 to connector P2 on the board with the PPDA. Other core PDM boards can use the P2 connector for this connection.

Operation:

The terminal block on the right side of the JPDB module has two AC power supplies connected to it. Below the IS200JPDB board, the AC power is directed to the AC line filter assembly.

The J1 connector on the JPDB circuit board is connected to the filter assembly via the wire harness.

The circuit board for the IS2020JPDBG01 module is the IS200JPDBH1A. since J1 is connected directly to the output branch circuit, this board is not used for AC power selector connections.

The IS200JPDBH2A board is used by the IS2020JPDBG02 module. This board requires an AC power selector.

The JSS1 connector is mounted on one of the boards.JSS1 receives externally filtered AC power from connector J1. To feed the power supply, the branch circuit outputs, and the source selector outputs are returned to JSS1.

The two DACA power conversion modules are powered by JAF1. which feeds power directly from input connector J1 to the adjacent optional JPDF board.

For systems utilizing 125 V DC batteries, the DACA modules are used as an AC backup power supply that converts AC power to 125 V DC power.

Woodward 2301A Electronic Load Sharing and Speed Control

Description

The 9905/9907 series of the Woodward 2301A controls load sharing and speed of generators driven by diesel or gasoline engines, or steam or gas turbines. 

These power sources are referred to as “prime movers” throughout this manual.

The control is housed in a sheet-metal chassis and consists of a single printed circuit board. All potentiometers are accessible from the front of the chassis.

The 2301A provides control www.cniacs.com in either isochronous or droop mode.

The isochronous mode is used for constant prime mover speed with:

 Single-prime-mover operation;

 Two or more prime movers controlled by Woodward load sharing control systems on an isolated bus;

 Base loading against an infinite bus with the load controlled by an Automatic Power Transfer and Load (APTL) Control, an Import/Export Control, a Generator Loading Control, a Process Control, or another load-controlling accessory.

The droop mode is used for speed control as a function of load with:

 Single-prime-mover operation on an infinite bus or

 Parallel operation of two or more prime movers.

The following is an example of the typical hardware needed for the 2301A system controlling a single prime-mover and generator:

 A 2301A electronic control

 An external 20 to 40 Vdc power source for low-voltage models; 90 to 150 Vdc or 88 to 132 Vac for high-voltage models

 A proportional actuator to position the fuel-metering device 

 Current and potential transformers for measuring the load carried by the generator.

Applications

The 2301A 9905/9907 series electronic controls have switch-electable speed ranges. Any of these control models can be set to operate within one of the following rated speed ranges:

 500 to 1500 Hz

 1000 to 3000 Hz

 2000 to 6000 Hz

 4000 to 12 000 Hz

Honeywell UDC1200 and UDC1700 Universal Digital Controllers

Product Overview

The UDC1200 and UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN controllers that offer high functionality, high reliability and low cost.

They are designed to monitor and control temperature, pressure and level in a variety of applications such as environmental chambers, furnaces, ovens, packaging machines and other applications in the plastics, food and beverage industries.

other applications in the industry.The UDC1200 and UDC1700 are easy to configure and use with large, easy-to-read dual 4-digit displays and touch-sensitive keypads.

Their outstanding flexibility allows you to configure any unit for any application and make changes when needed.

For the thousands of satisfied UDC1000/1500 users, the UDC1200/1700 controllers are backward compatible with existing UDC1000/1500 applications and installations.

Functional Features

Dual Displays

Two 4-digit displays with 7 LED segments, each configurable as

 PV and SP (non-adjustable)

 PV and SP (adjustable)

 PV and ramp SP

 PV only

Easier Configuration

Two different configuration levels (Configuration Mode and Setup Mode) provide easy access to parameters.

4-digit security code prevents unauthorised changes.

Positive Moisture Protection

Meets NEMA 3 / IP65 standards for frontal dust and water resistance.

Universal Inputs

Accepts seven different types of thermocouple, RTD, www.cniacs.com current and voltage linear inputs. All inputs can be configured as standard.

Universal Power Supplies

The UDC1200 and UDC1700 can operate on any line voltage from 50/60 Hz, 90 Vac to 264 Vac. Optional 24/48 Vac/dc models are also available.

Easy Upgrade

All option boards have no jumpers and are automatically detected by the instrument.

Easy Output Selection

All of the instrument’s outputs, including the control output, can be changed to meet the customer’s exact needs.

Kongsberg RCU500 Remote Control Unit

The RCU 500 is a stand-alone computer designed for process control.

Typical applications include

– Dynamic positioning systems

– Vessel control systems

– Process control systems

– Safety systems

Functional Features

– Power PC processor 8245. 400 MHz, running AIM and DP www.cniacs.com applications, 32 MB SDRAM memory and 16 MB flash memory

– Built-in self-test (BIST) device and error reporting system (via operator station)

– Watchdog with system status output

– Four general-purpose digital input channels

– Four general-purpose digital output channels

– Twelve general-purpose RS-232/RS-422/RS-485 serial line interfaces

– Four isolated RS-232/RS-422/RS-485 general-purpose serial line interfaces

– Dual CAN bus interfaces (1 Mbps)

– Dual Pro bus (12 Mbps)

– Serial Process Bus (SPBus) interface to RIO 400 remote I/O devices

– Dual 100 Mb Ethernet LAN connectors

– Prepare for redundant RCU operation

– Allows “hot swap” of RCU 500 in redundant systems

– Built-in high temperature and cooling fan alarms

– Easy to install and replace:

– DIN standard rail mounting

– Plug-in connection

– LED status indicator on the front

A-B 6189-RPEHA VersaView CE Logic Module

Description The 6189-RPEHA Logic Module is an Allen-Bradley/Rockwell Automation Logic Module in the VersaView CE Series.

It can be used as part of a human-machine interface when connected to a communication module and a display module.

The 6189-RPEHA Logic Module is AC powered and operates from 100 to 240 volts AC.

The 6189-RPEHA Logic Module has an operating temperature range of 32 to 131 degrees Fahrenheit and a non-condensing relative humidity of 10 to 90%.

The Allen-Bradley 6189-RPEHA is a VersaView CE logic module.

Allen-Bradley has discontinued this product and replaced it with the new 2711P-RP7A PanelView Plus CE Logic Module.

It is an intelligent controller that automates machine processes without user intervention.

Its modern, cost-effective and flexible design makes it ideal for complex or simply installed industrial applications.

It is compatible with all VersaView and PanelView Plus CE terminals.

The 6189-RPEHA module requires 100 – 240V AC input power.

For storage, it has a 2711P-RW3 built-in CompactFlash module containing 256 MB of user memory.

It is marine certified and meets the www.cniacs.com highest standards in the industry. All VersaView devices are now discontinued.

Allen-Bradley has rebranded it as part of the PanelView Plus product family.

It is suitable for use in a clean, dry, overvoltage Class II standard environment with an operating temperature of 0 – 55 °C (32 – 131 °F), an operating shock of 30 g, and a relative humidity of 5 – 90% (non-condensing).

Motorola MVME7100 VMEbus Single Board Computer

The MVME7100 increases performance and functionality while protecting the underlying investment in the VMEbus and related technologies

Up to 1.3GHz system-on-chip NXP MPC864xD, featuring dual PowerPC® e600

processor cores, dual integrated memory controllers, DMA engine, PCI Express

interface, Ethernet and local I/O

Extended temperature (-40 °C to +71 °C) and ruggedised board variants available

Four Gigabit Ethernet ports

Up to 2GB of DDR2 ECC memory, 128MB NOR flash and 2GB, 4GB or 8GB NAND flash

USB 2.0 controller for cost-effective peripheral integration (commercial temperature only)

2eSST VME bus protocol with 20MB/s VME bus transfer rate

Dual 33/66/100 MHz PMC-X interfaces, expandable with industry-standard modules

The MVME7100 provides a development path for VMEbus customers with applications on previous generation VMEs, in particular the MPC74xx processor. The system-on-chip implementation offers power/heat dissipation, reliability and lifecycle benefits that are typically found in other architectures.

which are typically not found in other architectures.

The SMART EC MVME7100 single board computer (SBC) helps OEMs of industrial, medical and defence/aerospace equipment to increase performance and functionality

to increase competitive advantage while protecting www.cniacs.com the underlying investment in the VMEbus and related technologies.

Customers can retain their VMEbus infrastructure (chassis, backplanes and other VMEbus and PMC boards) while improving performance and extending lifecycles.

In addition, the extended lifecycle of SMART EC computing products helps to minimise disruption to development and support due to frequent product replacement.

The combination of faster processors and the 2eSST VMEbus interface provides significant performance improvements. New cost-effective peripherals can be easily integrated using the USB interface.

The extended temperature (-40 °C to +71 °C) variant supports a wide range of operating and storage temperatures, in addition to increased shock tolerance.

This enables the board to operate in harsh environments while maintaining structural and operational integrity.

Motorola MVME162P4 VME Corporation Embedded Controller

■ Processor choice: 32 MHz MC68040 enhanced 32-bit microprocessor with 8KB cache and MMU and FPU;

or 25 MHz MC68LC040 enhanced 32-bit microprocessor with 8KB cache and MMU

■ A32/D64 VMEbus master/slave interface system controller functionality

High-performance DMA support for VMEbus D64 and local bus memory burst cycles

16MB of configurable SDRAM

■ 512KB SRAM with battery backup

■ 1MB Flash memory for on-board monitor/debugger or user-installed firmware

■ 8K x 8 NVRAM and clock backup with batteries

Two serial communication ports, console port for EIA-232-D DCE and second port user configurable for

EIA-232d/EIA-422 (V.36) DTE/DCE

■ Four 16-bit or two 32-bit IndustriPack® ports, one of which is a DMA channel per port

■ Optional SCSI and Ethernet interfaces

■ Six 32-bit timers, one watchdog timer

Four-slot IndustriPack logic interface for embedded www.cniacs.com monitoring and control

Applications

The MVME162P4 family provides an ideal platform for OEMs and solution developers of

for embedded monitoring applications. It allows OEMs to incorporate

engineering costs when integrating value-added hardware and software

applications to off-the-shelf products.

To provide this wide range of solutions, the MVME162P4 allows a variety of

MPU, memory and interface options such as floating point, Ethernet, SCSI and VME.

The result is a variant of the MVME162P4 that is best suited to application

requirements

HITACHI LYA010A Input/Output Module

OVERVIEW

Basic Details: LYA010A Input/Output Module HITACHI

1 PLC Input/Output Modules

Introduction 1.1 Digital and Analogue Signals

Digital input/output signals are switching signals, a 1 or a 0.

Analogue signals, there are two kinds of voltage signals or current signals, generally signals transmitted by the transmitter, such as pressure transmitter to detect the pressure of the water pipe, will output a 4-20ma or 0-10V analogue signal to the PLC, the PLC for data processing.

Switching input point (DI), processing switching input signal.

Analogue input point (AI), processing analogue input signals (0-20 MADc, 0-5VDC).

Resistance signal (including RTD) input point, processing RTD or general resistance signal.

High-speed pulse input point, processing high-speed pulse signals.

Voltage (including thermocouple) input point, processing voltage input or thermocouple signals.

There are also communication functions for data exchange with the host computer or control subordinate controller instrument driver

1.2 Digital and analogue input modules

According to the different field input signals, the input module can be divided into switching input module and analogue input module.

The function of the switching input module is to convert various switching signals into TTL standard signals required by the CPU. Depending on the type of input power supply, they can also be DC input modules and AC input modules. The input signals are converted to TTL (5V) standard signals by photocoupling after voltage division, current limiting, and filtering.

The function of the analogue input module is to convert www.cniacs.com changing analogue signals such as temperature, flow, current, voltage, etc. into a number of digital signals which can be processed by the CPU. The analogue input circuit is generally composed of operational amplifier conversion, mode conversion (A/D), and optoelectronic isolation.

PLC input and output module types: digital input DI, digital output DO, analogue input AI, analogue output AO.

Digital inputs and outputs are generally 24V.

ABB 3HNA023093-001 Thermocouple/mV Input Module

Size

Net weight: 5.9kg

Gross Weight: 5.9kg

Net depth/length: 435 mm

Net height: 120 mm

Net product width: 181 mm

Additional information

Frame size: Definition

Chinese name:PDB-02型

OVERVIEW

Basic Details: 3HNA023093-001 Thermocouple/mV Input Module

The 3HNA023093-001 Thermocouple/Millivolt Input Module is a module for temperature measurement that senses temperature changes via a thermocouple or millivolt signal input.

A thermocouple is a temperature sensor that uses the thermoelectric effect between two dissimilar metals to measure temperature. 

When the temperature changes, the thermocouple produces a voltage signal proportional to the change in temperature.

A millivolt input module is a module capable of receiving millivolt signals that can be converted to digital signals for subsequent processing and display.

3HNA023093-001 Thermocouple/millivolt input modules typically have the following functions:

Temperature measurement: with a thermocouple or millivolt signal input, the module is able to sense temperature changes and convert them to a digital signal output.

Signal Processing: Modules may have signal processing functions such as amplification, filtering, digitisation, etc. to improve measurement accuracy and stability.

Output Interface: Modules usually have an output interface to output digital signals to other devices or systems for display, control or recording.

Please note that the above functions may vary depending on the specific model and application requirements.

Therefore, when using the 3HNA023093-001 Thermocouple/Millivolt Input Module, it is recommended that you refer to its official documentation or contact the manufacturer for accurate and detailed functional information.

The 3HNA023093-001 Thermocouple/Millivolt Input Module works as follows:

A thermocouple is made by connecting one end of two different metallic materials together and connecting the other end to one of the terminals above, and then using a voltmeter to measure the voltage at the ends of the terminals, which can usually be measured as a small voltage value.

If the two wires are made of different materials, such as a copper wire and a wire, because the thermal conductivity effect of the two wires is not the same, and the temperature of the cold end of the two wires is not the same, which means that the number of free electrons is not the same, at this time, the voltmeter can measure the voltage value.

The 3HNA023093-001 thermocouple/millivolt input module is an ABB branded product for temperature measurement and conversion.

It measures the temperature directly and converts the temperature signal to a thermodynamic force signal, which is then converted to the temperature of the measured medium by means of an electrical instrument (secondary instrument).

Search for products

Back to Top
Product has been added to your cart