Product description
The MTL831B analogue transmitter can transfer a number of
hazardous area input signals to the safe area down a data highway
consisting of a single twisted pair cable. It is intrinsically safe and can
therefore be mounted in Zone 0 hazardous areas or Class I, Division
1 hazardous locations.
The MTL831B can monitor up to 16 inputs from THC or millivolt
sources or up to 15 inputs from 2. 3 or 4-wire RTDs.
Two (i.e. dual redundant) data highway outputs are provided that can
carry both signal and power over distances up to 3km, depending on
the application, the cable and the (noise) environment – see Section
4.4. The highway cables can be simple twisted-wire pairs or pairs of
wire within an IS multi-core cable.
At the other end of the data highway, MTL838B-MBF receivers are
used to translate the information transmitted from the MTL831B. The
MTL838B-MBF provides a Modbus®serial data output representation
of the inputs together with status information.
When the MTL831B transmitter is mounted in the hazardous area,
each data highway mustbe protected by an MTL3052 digital isolator
mounted in the safe area.