Principle of operation
The RTG employs the Frequency Modulated Continuous Wave
(FMCW) principle with dual sweep technology to eliminate
Doppler-effect caused by cargo movement. Frequency sweep
ing microwave signals are emitted from two separate electronic
units and through a common standpipe. The distance (i.e. the
ullage) is derived from the time delay of the reflected signal.
The standpipe is assembled by sections adjusted to match the
total tank height. The pipes have ventilation holes allowing the
vapour pressure inside and outside the pipe to stabilize, thus
allowing the liquid to rise or fall unimpeded in the pipe.
Each pipe section is supplied with flanges prepared with refer
ence markers. The liquid level and the markers are measured
simultaneously, so the system automatically verifies itself at
every measurement. By careful calibration of the pipe sections
length before installation, the positions of the markers are re
corded and stored in the system. By comparing the liquid echo
with the signature plate echo, a continuous auto-calibration of
the measurement is done.
The electronic units in the RTG includes a patented signal
detection method that ensures optimum performance. Com
bined with its superb signal-to-noise ratio, GLA-310/5 offers the
highest measurement reliability and accuracy.
Each electronic unit is connected to a dedicated signal process
ing unit, where the AutroCAL® principle is employed.