Welcome to the official website of CNIACS Automation Technology Co., Ltd!

IC200ALG262 8-Point Analog Current Input Module for VersaMax I/O Series

The IC200ALG262 is a component module of the VersaMax I/O platform. It is an analog input module designed to support differential current wiring.

It has eight (8) analog input channels designed to receive standard current input signals such as 0-20 mA and 4-20 mA input signals.

This IC200ALG262 is currently manufactured by Emerson Automation. It is ideally suited for connection to analog signal generating instruments such as field transmitters.

for measuring pressure, level, flow, temperature, turbidity, viscosity, speed, and other types of transmitters; for integrating locally mounted panel meters to

remote display; for monitoring the speed output of variable frequency drives (VFDs); for monitoring the position of rotary and linear devices; and other applications.

The IC200ALG262 has a built-in analog-to-digital converter (ADC) circuit with 15-bit conversion resolution. The input channels are arranged in groups.

When configured to receive 4-20 mA, they are capable of detecting power loss and open circuit detection within the module. Each channel has an uplink rate of 7.5 ms.

Each channel has an uplink rate of 7.5 ms and a digital resolution of 0.5 μA (4-20 mA signal range) and 0.625 μA (0-20 mA signal range). The module has a maximum backplane current consumption of 5 mA at 200 VDC bus voltage.

Compatible configuration software and hardware firmware versions that can be used with this module include VersaPro software version 2.0 or later; VersaMax PLC CPU CPU version 2.0 or later; and VersaMax PLC CPU version 2.0 or later.

IC695RMX128 PACSystems RX3i Redundant Memory Switch Module

​This IC695RMX128 is a PACSystems RX3i redundant memory switching module manufactured by Emerson Automation (formerly GE Intelligent Platforms (GE IP)).

The module has 128MB of SDRAM user memory and supports operation as a reflective memory network or dedicated link between RX3i CPUs in a redundant configuration.

The module comes with single-mode fiber that supports 2.12 Gbaud fiber networks.

About the IC695RMX128

The IC695RMX128 is the PACSystems RX3i Redundant Memory Exchange Module.

The primary function of the module is to act as a single node on a reflective memory topology or as a dedicated memory module for redundant RX3i CPU pairs.

When used in a redundant CPU configuration, the IC695RMX128 reflects the contents of the IC695CMX128.

With a reflected memory link, any updates on one node are reflected and updated to all other nodes connected to the same network.

Connections are established over a fiber optic network supporting up to 256 nodes.

The module is equipped with 128 MB of reflective memory, and the fiber optic power supply requires an LC-type connector for transmission speeds up to 2.12 Gbaud.

The module operates on supplies of 580 mA @ 3.3 VDC and 220 MA @ 5 VDC.

ABB REF620 IEC Feeder Protection and Measurement Control Unit

Main advantages

Devices can be used for a wide range of applications

Ranging from simple protection devices as backup protection to specialized protection devices

Well-established and modernized technology

Arc detection as an option

REF620 as a dedicated feeder protection device for the protection, control, measurement and monitoring of public and industrial power distribution systems.

REF620 IEC feeder protection and measurement and control device, as a dedicated feeder protection device, is specially designed for the protection, control, measurement and monitoring of public and industrial grids, including radial, ring and mesh grids.

The REF620 provides feeder overcurrent and earth fault protection that can be applied to both ungrounded neutral networks and resistance or impedance neutral grounded networks.

In addition, utilizing the unit’s advanced station-to-station communication capabilities, the REF620 can also be used for ring mesh distribution network or radial network protection.

The REF620 IEC Feeder Protection and Measurement Control Unit is available in single and dual busbar configurations, with one or two circuit breakers and multiple switchgear configurations for each busbar configuration.

The unit supports a large number of manual and motorized disconnect and ground switches. The number of available I/Os can be increased as required by ABB’s RIO600 remote I/O unit.

The REF620 IEC Feeder Protection and Control Unit features support for the IEC61850 communication standard for substations, covering both vertical and horizontal communications.

It includes GOOSE telegrams with switching and analog signals, and constant value adjustment based on IEC 61850-8-1.

The REF620 also supports DNP3. IEC 60870-5-103 and Modbus® protocols.

The REF620 provides an optional Ethernet port for non-delayed redundant Ethernet or a ring self-healing RSTP communication in the event of a communication failure via PRP or HSR protocols.

This solution eliminates the effects of a single point of failure and improves communication reliability. The solution can be applied to Ethernet based IEC 61850. Modbus® and DNP3 protocols.

Honeywell FC-SAI-1620M Safety High Density Analog Input Module

Introducing:

Honeywell Safety Manager™ is a reliable and highly complete safety system tailored for critical control applications.

It is an integral part of Honeywell Experion™ PKS and integrates seamlessly into PlantScape and can also operate autonomously.

Safety Manager is the foundation of functional safety, ensuring the well-being of individuals, plant assets and the environment while optimizing plant continuity.

Safety Manager is a user-programmable, modular, microprocessor-based safety system capable of performing a wide range of high integrity process control and safety instrumentation functions, including:

High integrity process control

Burner/boiler management systems

Process protection and emergency shutdown

Turbine and compressor safety protection

Fire and gas detection systems

Pipeline monitoring

Enhanced business results:

Safety Manager™ is an evolution of the proven Fail Safe Controller (FSC®) safety system platform that has been globally recognized for more than 15 years.

It embodies proven technology backed by Honeywell’s two decades of expertise in process safety management. This includes the integration of process safety data, applications, system diagnostics and critical control strategies.

Safety Manager is designed to enhance business performance, improve process safety and protect plant assets and people.

The safety system is seamlessly integrated with the Experion™ Process Knowledge System (PKS) into a single architecture, providing an excellent opportunity to improve safety and process availability.

Experion PKS ensures unparalleled connectivity between processes and business operations, optimizes workflows, simplifies maintenance tasks, enhances safety management, and frees personnel from manual tasks.

Triconex 4351B Tricon Communication Module

Tricon Communication Module

The Tricon Communication Module (TCM) is compatible with Tricon v10.0 and later systems only.

Allows Tricon to communicate via Ethernet with TriStation, other Tricon or Trident controllers, Modbus master and slave devices, and external hosts.

Each TCM contains 4 serial ports, 2 network ports, and 1 debug port (for Triconex).

Each serial port is uniquely addressed and can be configured as a Modbus master or slave.

Serial port #1 supports Modbus or Trimble GPS www.cniacs.com interface. Serial port #4 supports Modbus or TriStation interface.

Each TCM supports an aggregated data rate of 460.8 Kb/s for all four serial ports.

Tricon programs use variable names as identifiers, while Modbus devices use numeric addresses called aliases.

Therefore, each Tricon variable name must be assigned an alias that will be read by or written to the Modbus device.

An alias is a five-digit number that represents the Modbus message type and the address of the variable in the Ticon. An alias number is assigned in the TriStation.

Any standard Modbus device can communicate with Tricon via TCM, provided an alias is assigned to the Tricon variable.

The alias number must also be used when the host accesses the Tricon through other communication modules.

Each TCM contains two network ports – NET 1 and NET 2. Models 4351A and 4353 have two copper Ethernet (802.3) ports and Models 4352A and 4354 have two fiber optic Ethernet ports.

NET 1 and NET 2 support TCP/IP, Modbus TCP/IP Slave/Master, TSAA, TriStation,

The NET 1 also supports the Peer-to-Peer and Peer-to-Peer Time Synchronization protocols.

A single Tricon system supports up to four TCMs, which must reside in two logical slots.

Different TCM models cannot be mixed in a logical slot.

Each Tricon system supports a total of 32 Modbus masters or slaves, including network and serial ports.

The hot standby feature does not apply to TCMs, but you can replace a defective TCM while the controller is online.

VMIVME-2510B 64-bit TTL Digital Input/Output (with Built-in Test)

Features:

. Direction of each 8-bit port is individually programmable

.64 mA sink current capability (15 mA source) .

. Separate board address decoding for control and data registers .

. Built-in test logic for fault detection and isolation .

. Highly reliable DIN-type I/O connectors .

. 8-bit, 16-bit, 32-bit transfers

The VMIVME-2510B is a member of the VMIC Megamodule family, which is designed for universal programming.

The subsystem can be configured with consecutive www.cniacs.com I/O addresses to conserve memory.

These products (VMIVME-1110. VMIVME-2120. VMIVME-2130. and VMIVME-2510B) are designed with two sets of board address switches to provide efficient memory address mapping for CSR and I/O addresses.

The CSR address switches can be configured so that all CSRs on the various boards in the system can be mapped to contiguous memory locations.

Megamodule products are also designed to support 8-bit, 16-bit and 32-bit data transfers.

Specific hardware has been designed into the VMIVME-2510B to support the built-in test functions.

The VMIVME-2510B supports off-line and on-line fault detection and isolation. The front panel Fail LED is used to indicate when a fault exists on this board.

The LED is illuminated at power-up or reset. The LED can be turned off after successfully completing board level diagnostics.

Honeywell 05701-A-0511 5701 Series Control System

Key Features

The 5701 Series Control System is part of the 57 System family and is designed to monitor and control field installed industrial gas detectors.

The key features of the system are as follows.

Provides up to 16 gas detection channels in a standard 19” subrack using a 3U card format.

Provides up to 8 gas detection channels in a 3U card format in a half 19” subrack.

Racks are available for both front and rear wiring.

Simple field connection for wires up to 2.5mm2.

Single channel operation mode for high integrity systems.

Channel control cards are removable and do not interfere with other wiring.

Catalytic bridge or 4 – 20mA input.

Optional alarm switching relay output.

Multi-alarm modes for master, zone and voting alarms.

UP, DOWN, STEL and LTEL / RATE alarm outputs.

Update alarms for single or multi-channel alarms.

Remote inhibit and reset inputs.

Relay output on and/or off delay.

Selectable 0 – 20mA or 4 – 20mA isolated monitor outputs.

Easy calibration and operation with dedicated engineering card.

EMC compliant.

IBA ibaLink-SM-128V-i-2o VMEbus Interface Card

Introduction

The ibaLink-SM-128V-i-2o VMEbus Interface Card is a multi-purpose, bi-directional interface card designed for use in VMEbus-compatible PLCs and computer systems.

It can be used for both data acquisition and process monitoring as well as for control system applications such as the ibaLogic SoftPLC.

In the following, the board will be named SM128V to simplify the description.

Key features of the SM128V include :

 1 bi-directional fiber optic link with 64A+64D inputs/outputs per link (channel 1)

 1 unidirectional fiber optic link with 64A+64D outputs per link (channel 2)

 Synchronized transmission of all channels on both links at a rate of 1ms

 Address switch for cascading up to 8 SM128V interface cards on a link

Channel 1

 Compatible interface for ibaFOB-io, ibaFOB -4i (-S), ibaFOB-4o

 Compatible process i/o interface for ibaPADU-8-IO series and ibaNet750-BM series

 5 V power supply from VMEbus

Multilin 169PLUS-120N-125VDC Motor Management Relay

The 169PLUS-120N-125VDC is a highly configurable motor protection system manufactured by General Electric Multilin.

The relay comes with basic setpoints programmed for large motor systems, which can be further adjusted by the user upon receipt of the relay or as they become more familiar with the data generated by the relay.

While users can manage their motor systems with fairly minimal connection to GE Multilin’s 169PLUS-120N-125VDC.

However, the unit does offer a wide range of ports to diversify and customize the function of the relays.

Some of these connections include:

. Auxiliary Relay Contacts: these two contacts provide an additional NO/NC connection and operate independently of the other contacts.

The relays can be configured as non-fail-safe or fail-safe, and latching or non-latching.

They can be used for active alarm or trip functions and can trigger devices that are not just motors.

RTD Sensor Connections: The user can connect up to 6 resistance temperature detectors.

This is used to monitor values such as stator motor temperature, historical hottest temperature and ambient air temperature.

The relay then uses the data obtained from these connections to schedule the optimal cooling process.

. Analog output terminals: These two terminals can be configured using the relay’s setpoint system.

It can be connected to chart recorders, remote meters, programmable recorders and/or computer loads.

. Emergency Restart Terminal: This connection type overrides trips within the system and forces a restart of the motor.

These connections add to the overall versatility of the system and can further protect motor components from damage during operation.

Vibro-Meter VM600Mk2/VM600 ABE056 Slimline Racks

VM600 ABE056 Ultra Slim Racks

(houses the MPC4 mechanical protection card)

Key Features and Benefits

– From the vibro-meter® product family

– 19-inch slim rack with 1U standard height

– Rugged metal construction

– Modular concept allows the addition of specific modules (cards) for machine protection or condition monitoring

– Rack or panel mounting

– Backplane supports open collector (OC) bus and power distribution for VM600Mk2/VM600 systems

– Integrated AC input or DC input power supply

– Power check relay

Applications

– VM600Mk2/VM600 Mechanical Protection and/or Condition Monitoring Systems

VM600Mk2/VM600 Mechanical Protection and/or Condition Monitoring Systems

The VM600Mk2/VM600 ABE056 slimline rack is used to house the hardware for the VM600Mk2/VM600 series of machine protection and/or condition monitoring systems in the Vibrometer® product line.

The VM600Mk2/VM600 ABE056 slimline rack has a standard height of 1U and provides mounting space (rack slots) for a single wide VM600Mk2/VM600 processing module (card pair) and a relay module (card).

This rack is particularly suitable for industrial environments where the equipment must be permanently installed in a 19-inch cabinet or panel.

Different versions of the integrated RPS1U power supply can power the VM600Mk2/VM600 ABE056 slimline racks from an external AC or DC power supply.

Both power supplies support a wide input voltage range.

The rack has an integrated backplane that provides electrical interconnection between the integrated power supply (RPS1U) and the installed VM600Mk2/VM600 modules (cards).

The rack also has a power check relay on the rear of the rack to indicate if the integrated power supply is functioning properly.