User-Friendly Quick Start Menu
For Easy Set-Up and Application
Adjustable parameters include:
• Maximum speed
• Minimum speed
• Linear acceleration
• Linear deceleration
• Current limit (positive and negative on
regenerative modules)
• I/R compensation (voltage regulated drives)
• Jog speed
• Jog acceleration/deceleration rate
• Reverse disable on regenerative drives
12-Bit Resolution Analog Signals
For Exceptional Accuracy
• 10 VDC manual speed reference
• User selectable +/- 10 Volt or 4-20 mA
auto speed reference
• 0-10 VDC analog output proportional to speed
• 0-10 VDC analog output proportional to armature current
• Speed feedback from analog tachometer (250 VDC maximum input)
Expanded Offering of Digital Signals
For Optimum Flexibility
• Coast, stop, auto/manual, forward/reverse, jog, run, and stop inputs
• Motor thermostat diagnostic input
• Brush wear diagnostic input
• Customer interlock diagnostic input
• Drive running contact output
• Drive alarm contact output
• Drive fault contact output
Feature-Rich “Standard” Package
For Exceptional Functionality
• Self-tuning of speed and current loops without
disconnecting the fields
• Field (current) loss protection
• User selectable stop modes
– Coast
– Current limit
– Ramp
• Local controls with interactive keypad and display for:
– Drive set-up
– Drive operation
– Metering and diagnostics (including fault and alarm logs)
Leave a comment