Manually Stroking QuickTrip Using ProTechTPS (powered)
Manually stroking valve using ProTechTPS procedure:
1. If QuickTrip is in a run state, as indicated by a green LED as viewed through the sight glass,
QuickTrip may be manually tripped by de-energizing the ProTechTPS interposing relay to initiate a
trip. This may be done by using the Temporary Overspeed Setpoint Test (see ProTechTPS product
manual for more detailed instructions on this function).
2. If QuickTrip is in a trip state, as indicated by a red LED as viewed through the sight glass, QuickTrip
may be energized to close by activating the ProTechTPS interposing relay to initiate a run state. This
may be done by pressing the RESET button on the front panel of the ProTechTPS (see the
ProTechTPS product manual if module does not reset when the RESET button is pressed).
The user is permitted to replace some components of the QuickTrip in turbine shutdown conditions. The
user is also permitted to replace some components of the QuickTrip during normal turbine operation
conditions. The replacement components must be Woodward recommended products. Only this
guarantees full component compatibility and functionality. All safety instructions and detailed procedures
from this manual must be followed.