Description
The actuators are designed to be base- or flange-mounted (Model IV is base
mounted only) in an on-engine environment and can therefore withstand high levels
of vibration and temperature extremes. They all have a 0.625-36 serrated tooth
terminal shaft, and an optional rotation scale and indicator are available for visible
travel detection. The actuators accept analog or PWM position command signals. In
addition, the Digital Plus driver accepts CAN position command signals and can be
configured for redundant command signals. It monitors all available internal and
external signals, and annunciates any detected faults through a discrete output. An
analog output provides actual position indication, and a discrete input is available to
remotely shut down the actuator.
Additional features of the Digital Plus driver include on-line and off-line diagnostics,
current limiting based on driver electronics temperature, CAN communications, and
service port communications. The Digital Plus driver is field programmable, allowing
a single design to be used in many different applications. It must be configured and
calibrated to the specific engine with a personal computer (PC) and a Woodward
Watch Window Service Tool that communicates serially to the driver via RS-232
using Woodward’s DDE ServLink protocol.