OVERVIEW
Operating principle
• Input current flows through the coils of a torque motor, providing magnetic
power and polarity to the armature.
• Due to the magnetic relationship between the upper and lower poles, the
armature inclines depending on the size of the input current and the polarity
(torque generation).
• The flapper is located between the left and right nozzles and is joined with
the armature. Therefore, a change in the inclination of the ar mature changes
the flapper position, changing the aperture of the left and right nozzles.
• In 3-way valves, the control pressure changes from the supply pressure to
the air pressure according to the aperture of the left and right nozzles.
Therefore, these valves can output control pressure according to the input
current.
• In 4-way valves, two control ports provide output that is roughly
proportional to the input current.
Characteristics
• Single-stage type nozzle flapper valves with torque motors
• High resolution and low hysteresis
• Compact and light
• Low power consumption
• High responsiveness
• Sturdy long-life design free of sliding surfaces
Leave a comment
Your email address will not be published. Required fields are marked *