INSTALLATION
The Moog 79 Series Industrial Servovalve may be mounted in any position,
provided the servovalve pressure,control,and return ports match respective
manifold ports.
Caution: If the servovalve is mounted vertically,the third stage spool may drift
to one side when hydraulics are shut off.This may result in sudden movement of
equipment when starting up.
The mounting pattern and port location of the servovalve is shown on
Figure 2.The servovalve should be mounted with 5/8-11 x 2.5 inch long high
strength socket head capscrews.Apply a light film of oil to the screw threads
and torque to 215 foot pounds.
On selected models,the pilot valve supply and return may be supplied
through external lines attached to the valve body or an intermediate manifold.
High response valves with stub shafted spools will require the installation of a
drain line to the non transducer end cap.
Wire mating connector for desired coil configuration and polarity.Thread
connector to valve.Wire transducer according to the installation drawing,figure 2.