HYDRAULIC SYSTEM PREPARATION

To prolong servovalve operational life and to reduce hydraulic system

maintenance,it is recommended that the hydraulic fluid be kept at a cleanliness

level of ISO DIS 4406 Code 16/13 maximum,14/11 recommended.The most

effective filtration scheme incorporates the use of a kidney loop or “off-line”

filtration as one of the major filtration components.The filter for the “off-line”

filtration scheme should be a ß3≥75 filter for maximum effectiveness.

Upon system startup and prior to mounting the servovalve,the entire

hydraulic system should be purged of built-in contaminating particles by an

adequate flushing.The servovalve should be replaced by a flushing manifold and

the hydraulic circuit powered up under conditions of fluid temperature and fluid

velocity reasonably simulating normal operating conditions.New system filters

are installed during the flushing process whenever the pressure drop across the

filter element becomes excessive.The flushing processes should turn over the

fluid in the reservoir between fifty to one hundred times.

To maintain a clean hydraulic system,the filters must be replaced on a

periodic basis. It is best to monitor the pressure drop across the filter assembly

and replace the filter element when the pressure drop becomes excessive. In

addition to other filters that are installed in the hydraulic circuit,it is

recommended that a large capacity,low pressure ß3≥75 filter be installed in the

return line.This filter will increase the interval between filter element

replacements and greatly reduce the system contamination level.