Welcome to the official website of CNIACS Automation Technology Co., Ltd!

ABB’s Measurement and Analytics portfolio

Measurement made easy

To run any process efficiently, measurement, execution, recording and control are essential,

Record and control. By choosing ABB, you are choosing a partner that can provide the best measurement and analysis solutions for your needs.

thereby maximizing the return on your investment. When you invest in ABB’s measurement and analysis solutions, you get the best technology, reliability and service in the industry.

R&D is a key source of ABB’s technological leadership.

ABB is constantly developing new applications based on existing technologies and continues to develop the breakthrough technologies needed to meet the challenges of the future.

ABB is constantly developing new applications based on existing technologies and continues to develop the breakthrough technologies needed to meet the challenges of the future.

Comprehensive measurement solutions Tailored to each industry

ABB’s measurement and analytics products provide world-class measurement solutions for any industry, utility or municipality. Latest

Innovations provide technical solutions that make running your plant easier.

ABB’s measurement and analysis products are based on universal technology, offering a common look and feel and method of operation. As a result, products are easy to configure, easy to integrate and easy to maintain.

ABB’s measurement and analysis portfolio

– Analytical Measurement

– Flow measurement

– Pressure measurement

– Temperature measurement

– Level measurement

– Actuators and Positioners

– Recorders and Controllers

– Device Management, Fieldbus and Wireless

– Force Measurement

– Services

ABB REG216 Digital Generator Protection Module Features

Functional Features

– Modular hardware

– Selectable protection functions

– Multiple applications

– Computerized menu-assisted setup

– All-digital signal processing

– Continuous hardware self-monitoring

– Cyclic test program mainly performed by software

– Parameterization and recording of set values via PC

– Display of measured values

– Event display, acknowledgement and printing

– Interference logging

– Self-logging

– Long-term stability

– Communication and coordination with control stations

– Available in two design versions: REG216 / REG216 Classic

Areas of application

The REG216 is used to protect generators and transformers.

The modular hardware and software design allows extremely flexible installation.

The combination of software libraries and hardware allows simple adaptation to the size of the primary system and the required protection scheme.

The combination of software libraries and hardware modules allows easy adaptation to the size of the primary system and the required protection scheme.

Modules. As a result, economical solutions can be realized in a wide range of applications.

Economical solution.

The REG216 software system provides a library of protection functions. The following table lists the functions applicable to generator and transformer protection.

Different levels of redundancy can be selected.

The availability and reliability of the protection can be selected according to the application in the following ways

For example, the auxiliary power supply unit for the entire system can be replicated.

Standard interfaces make the REG216 compatible with different process control systems.

ABB REG216 Digital Generator Protection Module Building Engineering

Construction

Hardware

The REG216 device consists of two main components, which are physically separated from each other and connected by standard prefabricated shielded cables

Connected by standard prefabricated shielded cables:

– The main system interface (CT, PT and auxiliary relays), which provides DC isolation and EMI barriers.

Isolation and EMI barrier

– Parallel bus and associated electronic units (e.g. analog inputs and data processors / for signal conditioning and processing).

The complete protection scheme consists of a relatively small number of hardware modules, allowing subsequent expansion of the electronic units and interfaces. Each device frame provides 21 rack spaces.

All hardware can be housed in a single compartment, which provides further shielding against inductive interference and physical protection against dust, etc.

All hardware can be accommodated in a single compartment, which provides further shielding from inductive interference and physical protection from dust.

The REG216 is available in 17 predefined rack configurations with a limited number of I/Os, but is equipped with the same SW library as the classic system.

Protective relays for other functions are not part of the EG216 and can be installed in compartments and interconnected with the REG216 accordingly.

Interfaces to the main system

The following modular components provide the interface between the REG216 and the power system.

Input transformer assembly

216GW62 This assembly is used to adjust the signal level and to isolate the primary system CT and PT circuits from the electronic circuits of the protective devices.

One PT and two CTs are available to meet different accuracy and dynamic performance requirements.

Up to 12 transformers can be accommodated, selected according to application requirements. Up to four components, i.e. 48 inputs, can be used.

Auxiliary relay and optocoupler assembly 216GD61a

This assembly is for use with the REG216 version. It provides eight trip relays,

Each relay has powerful potential-free trip contacts (with surge circuit), 16 auxiliary relays and 16 optocouplers.

relays and 16 optocoupler input circuits. Up to four assemblies are available.

Input Auxiliary Relay Assembly 216GE61

Up to 16 auxiliary relays to provide full potential isolation for digital input signals.

Output Auxiliary Relay Assembly 216GA61

Up to 16 auxiliary relays providing full potential separation for digital output signals (two contacts per signal).

Trip Auxiliary Relay Assembly 216GA62

Provides up to 8 powerful potential-free trip contacts and circuits that provide high-speed operation (surge circuits) and reduced consumption after operation (economy circuits).

The Trip Auxiliary Relay Assembly is available with an optional trip logic diode matrix for direct coupling of external signals.

Matrix for direct coupling of external signals The REG216 can also read and process external signals via digital inputs.

Different trip circuit monitoring arrangements for use with output unit 216DB61 and input auxiliary relay assembly 216GE61 are available.

ABB REF610 Feeder Line Protection Relay Product Overview

Product overview

3.1 Purpose of the relay

The feeder protection relay REF610 is a multifunctional protection relay primarily used to protect incoming and outgoing lines in various feeder applications.

The relay is based on a microprocessor environment. A self-monitoring system continuously monitors the operation of the relay.

The human-machine interface includes a liquid crystal display (LCD) that makes local use of the relay safe and easy.

The relays can be controlled locally via serial communications from a computer connected to the front communication port.

Remote control is available through a serial communications bus connected to the rear connector of the control and monitoring system.

3.2. Features

* Three-phase non-directional overcurrent protection with timing or IDMT characteristics and low rectification phase.

* Three-phase non-directional overcurrent protection, high rectification phase

* Three-phase non-directional overcurrent protection, instantaneous stage

* Non-directional ground fault protection with timing or IDMT characteristics, low setting stage

* Non-directional ground-fault protection, high-calibration phase.

* Phase discontinuity protection

* Three-phase cable thermal overload protection

* Arc protection

* Two lens sensors for arc detection (optional)

* Automatic adjustment of reference level according to backlight intensity

* Arc detection by remote light signal

* Automatic reclosing 1…. .3 times

* Circuit breaker fault protection

* Trip counter for circuit breaker status monitoring

* Trip circuit monitoring with routing of warning signals to signal outputs

* Trip lockout function

* Four accurate current inputs

* User selectable rated frequency 50/60 Hz

* Three normally open power output contacts

* Two change-over signaling output contacts and three additional change-over signaling output contacts on optional I/O module

* Output contact functions can be freely configured according to requirements.

ABB REF610 Feeder Line Protection Relay Technical Description

Outputs

The relay is equipped with

* three power output contacts PO1. PO2 and PO3

* two signal output contacts SO1 and SO2

* three optional signal output contacts SO3. SO4 and SO5

Switch group SGR1…. .8 is used to route internal signals from the protection stage, external trip signals and signals from the automatic reclosing function to the required signal or power output contacts.

The minimum pulse length can be configured as 40 or 80 ms and the power output contacts can be configured as latching.

Trouble Logger

The relay has a built-in disturbance logger that records the instantaneous measured value or the RMS curve of the measured signal.

and up to eight user-selectable digital signals: digital input signals and internal signals from the protection stage.

Any digital signal can be set to trigger the recorder on the falling or rising edge.

Front Panel

The relay front panel consists of

* 2 × 16 character alphanumeric LCD with backlight and automatic contrast control Controls

* Three LED indicators (green, yellow, red) with fixed functions

* Eight programmable LED indicators (red)

* HMI button section with four arrow buttons as well as clear/cancel and enter buttons for navigating through the navigation bar.

HMI button section with four arrow buttons as well as clear/cancel and input buttons for navigating through the menu structure and adjusting setting values

* Optically isolated serial communication port with LED indicators.

HMI passwords are divided into two levels: the main HMI setup password for all settings and the HMI communication password for communication settings only.

HMI passwords can be used to protect all user changeable values from being changed by unauthorized personnel.

Both the HMI setup password and the HMI communication password are inactive and are not required to change parameter values until the default HMI password is changed.

Non-Volatile Memory

The relay can be configured to store various data in non-volatile memory, even in the event of loss of auxiliary voltage (as long as the battery is inserted and charged), the

The non-volatile memory retains data even in the event of loss of auxiliary voltage (as long as the battery is inserted and charged). Operation indication messages and LEDs, interference logger data,

The EEPROM does not require a battery backup.

Fanuc IC694MDL940 PAC System RX3i Discrete Output Module

The IC694MDL940 is a PACSystem RX3i Discrete Output Module, formerly manufactured by GE Fanuc and now part of Emerson Automation.

The module has sixteen (16) normally open (N.O.) contacts divided into four (4) banks of four (4) outputs each.

Each contact output can operate at 5-30 VDC with a nominal voltage of 24 VDC; 5 – 250VAC at 47 to 63 Hz with a nominal input voltage of 120/240VAC.

Each channel is designed for a 2 Amp lead load, a maximum load per output and a maximum load of 4 Amps per common.

The module has a current draw of 7 mA with all outputs turned on by the 5 V bus on the backplane and 24 mA with all outputs turned on by the relay 135V bus on the backplane.

The IC694MDL940 is a sixteen (3) point relay output module for the Emerson Automation PACSystem RX16i series, formerly manufactured by GE Intelligent Platforms (GE IP).

The module has a single slot width, occupies a single slot on the backplane, and comes with four (4) output groups of four (4) relay outputs each.

The IC694MDL940 relay contacts are normally open (N.O.) contacts or type A contacts. Each output contact is rated for a maximum load of 2 amps pilot load.

Each output is rated for a maximum load, and each output group is designed to provide a maximum output current of 4 amps.

In addition, the module has a minimum load of 10 mA and a maximum inrush current of 5 amps. Each relay output channel has a response time of 15 ms.

For the maximum of two signal transitions, the module draws 7 mA @ 5VDC bus voltage and 24 mA for the relay 135V bus on the backplane.

These power ratings are based on all output channels energized.

The IC694MDL940 is equipped with sixteen (16) status LEDs, each representing an individual channel.

The energized LEDs indicate energized outputs and the de-energized LEDs indicate other outputs.

The module does not have a built-in mounted fuse for channel protection; therefore, the user may need to install an external fuse to protect the module.

This IC694MDL940 has 250 VAC continuous and 1500 VAC (1-minute isolation rating) from field to backplane and frame to ground.

And channel-to-channel isolation is 250 VAC continuous; 1500 VAC for 1 minute.

Fanuc IC694MDL930 Relay Output Module

About the IC694MDL930

This IC694MDL930 is part of the PACSystem RX3i midrange programmable automation controller (PAC) platform.

It is designed for use as a relay output module with eight (8) independently isolated normally open (N.O.) or A-type contact outputs.

Each output contact essentially has a separate common and dry contact, allowing different voltage types and levels to be connected exclusively to the module.

i.e. 5-30 VDC (nominal 24 VDC) and 5-250VAC (nominal 120/240VAC).

The current capacity of each output channel is 4 amps www.cniacs.com per output when used with resistive loads and 2 amps per output when used with pilot load devices.

Current capacity is 2 amps per output channel. For UL installations, the maximum load current that the module can withstand is 30 amps and varies according to ambient temperature.

Conversely, the minimum load that the module can withstand is 10 mA, and the module’s output channels have a typical response time of 15 ms between on and off switching, while the module’s maximum backplane current is 2 amps.

The module’s maximum backplane current draw is 6 mA, and all outputs are energized by a 5 VDC bus on the backplane.

All outputs are energized by a relay 70VDC bus on the backplane and the maximum backplane current consumption is 24mA.

The module also supports mounting to 90-30 series backplanes. It can be used as a local output module, mounted on a central processing unit (CPU) chassis, or with an appropriate communications adapter.

It can also be mounted on an extended remote distributed I/O station with appropriate communication adapters.

It is classified as a high voltage module and has eight (8) status LEDs to characterize the energized state of each output channel.

The module does not come with channel protection such as fuses or RC buffer circuits.

The IC694MDL930 RX3i is a 3-channel relay output module for the GE Fanuc RX8i PACSystems discrete I/O PLC series.

Fanuc IC200ALG262 8-Point Analog Current Input Module for VersaMax I/O Series

About the IC200ALG262

The IC200ALG262 is a component module of the VersaMax I/O platform. It is an analog input module designed to support differential current wiring.

It has eight (8) analog input channels designed to receive standard current input signals such as 0-20 mA and 4-20 mA input signals.

This IC200ALG262 is currently manufactured by Emerson Automation. It is ideally suited for connection to analog signal generating instruments such as field transmitters.

for measuring pressure, level, flow, temperature, turbidity, viscosity, speed, and other types of transmitters; for integrating locally mounted panel meters to

remote display; for monitoring the speed output of variable frequency drives (VFDs); for monitoring the position of rotary and linear devices; and other applications.

The IC200ALG262 has a built-in analog-to-digital converter (ADC) circuit with 15-bit conversion resolution. The input channels are arranged in groups.

When configured to receive 4-20 mA, they are capable of detecting power loss and open circuit detection within the module. Each channel has an uplink rate of 7.5 ms.

Each channel has an uplink rate of 7.5 ms and a digital resolution of 0.5 μA (4-20 mA signal range) and 0.625 μA (0-20 mA signal range). The module has a maximum backplane current consumption of 5 mA at 200 VDC bus voltage.

Compatible configuration software and hardware firmware versions that can be used with this module include VersaPro software version 2.0 or later; VersaMax PLC CPU CPU version 2.0 or later; and VersaMax PLC CPU version 2.0 or later.

VersaMax PLC CPU firmware version 2.10 or higher; VersaMax Ethernet Network Interface Unit (NIU) firmware version 1.10 or higher.

It is also compatible with VersaMax DeviceNet, Profibus or Genius NIU modules.

IC695RMX128 PACSystems RX3i Redundant Memory Switch Module

This IC695RMX128 is a PACSystems RX3i redundant memory switching module manufactured by Emerson Automation (formerly GE Intelligent Platforms (GE IP)).

The module has 128MB of SDRAM user memory and supports operation as a reflective memory network or dedicated link between RX3i CPUs in a redundant configuration.

The module comes with single-mode fiber that supports 2.12 Gbaud fiber networks.

About the IC695RMX128

The IC695RMX128 is the PACSystems RX3i Redundant Memory Exchange Module.

The primary function of the module is to act as a single node on a reflective memory topology or as a dedicated memory module for redundant RX3i CPU pairs.

When used in a redundant CPU configuration, the IC695RMX128 reflects the contents of the IC695CMX128.

With a reflected memory link, any updates on one node are reflected and updated to all other nodes connected to the same network.

Connections are established over a fiber optic network supporting up to 256 nodes.

The module is equipped with 128 MB of reflective memory, and the fiber optic power supply requires an LC-type connector for transmission speeds up to 2.12 Gbaud.

The module operates on supplies of 580 mA @ 3.3 VDC and 220 MA @ 5 VDC.

The IC695RMX128 is intended for use in redundant systems and cannot be used to perform general purpose memory Xchange functions.

In addition, a full communication path must be established to complete the Memory Xchange network. The complete communication path consists of the primary RMX unit and the corresponding secondary RMX unit.

Two (2) high speed fiber optic cables must be connected www.cniacs.com to the RMX pair and must form a 2-node ring.

No other RMX or reflective nide may be used in any redundant controller design since a dedicated RMX module must be used for redundant controller configuration.

Configuration of the RMX nodes is done via programming software, not via jumper or DIP switch settings.

ABB REF620 IEC Feeder Protection and Measurement Control Unit

Main advantages

Devices can be used for a wide range of applications

Ranging from simple protection devices as backup www.cniacs.com protection to specialized protection devices

Well-established and modernized technology

Arc detection as an option

The REF620 is a member of the 620 Protection, Measurement and Control product family within the ABB Relion® product family.

Key benefits

Protection, control, monitoring and management integrated in a single relay provides a compact and versatile solution for public and industrial power distribution systems

Wide range of protection and control functions, either with sensors or conventional CTs and PTs

Functional scalability and wide range of applications allow users to easily customize configuration applications to meet specific requirements

Pluggable design for quick installation and testing

Large LCD screen with single-line graphic display, accessible locally or via an easy-to-connect and navigate HMI

Thoughtful product lifecycle service

Key Features

Wide range of protection and control functions for incoming or outgoing applications

Multi-frequency conductive earth protection package with high sensitivity and selectivity

State-of-the-art, fast short-circuit and earth fault localization

Several optional function packages – for distributed generation, capacitors, basic motor and arc-light protection

Supports IEC61850 Version 1 and Version 2. including redundant HSR and PRP, GOOSE and IEC61850-9-2

Supports Modbus, DNP3. IEC 60870-5-103 communication protocols and different time synchronization methods, including IEEE 1588 v2 precision time protocols