ABB REG216 Digital Generator Protection Module Features

Functional Features

– Modular hardware

– Selectable protection functions

– Multiple applications

– Computerized menu-assisted setup

– All-digital signal processing

– Continuous hardware self-monitoring

Cyclic test program mainly performed by software

– Parameterization and recording of set values via PC

– Display of measured values

– Event display, acknowledgement and printing

– Interference logging

– Self-logging

– Long-term stability

– Communication and coordination with control stations

– Available in two design versions: REG216 / REG216 Classic

Areas of application

The REG216 is used to protect generators and transformers.

The modular hardware and software design allows extremely flexible installation.

The combination of software libraries and hardware allows www.cniacs.com simple adaptation to the size of the primary system and the required protection scheme.

The combination of software libraries and hardware modules allows easy adaptation to the size of the primary system and the required protection scheme.

Modules. As a result, economical solutions can be realized in a wide range of applications.

Economical solution.

The REG216 software system provides a library of protection functions. The following table lists the functions applicable to generator and transformer protection.

Different levels of redundancy can be selected.

The availability and reliability of the protection can be selected according to the application in the following ways

For example, the auxiliary power supply unit for the entire system can be replicated.

Standard interfaces make the REG216 compatible with different process control systems.

ABB REG216 Digital Generator Protection Module Building Engineering

All hardware can be housed in a single compartment, which provides further shielding against inductive interference and physical protection against dust, etc.

All hardware can be accommodated in a single compartment, which provides further shielding from inductive interference and physical protection from dust.

The REG216 is available in 17 predefined rack configurations with a limited number of I/Os, but is equipped with the same SW library as the classic system.

Protective relays for other functions are not part of the EG216 and can be installed in compartments and interconnected with the REG216 accordingly.

Interfaces to the main system

The following modular components provide the interface between the REG216 and the power system.

Input transformer assembly

216GW62 This assembly is used to adjust the signal level and to isolate the primary system CT and PT circuits from the electronic circuits of the protective devices.

One PT and two CTs are available to meet different accuracy and dynamic performance requirements.

Up to 12 transformers can be accommodated, selected according to application requirements. Up to four components, i.e. 48 inputs, can be used.

Auxiliary relay and optocoupler assembly 216GD61a

This assembly is for use with the REG216 version. It provides eight trip relays,

Each relay has powerful potential-free trip contacts (with surge circuit), 16 auxiliary relays and 16 optocouplers.

relays and 16 optocoupler input circuits. Up to four assemblies are available.

Input Auxiliary Relay Assembly 216GE61

Up to 16 auxiliary relays to provide full potential isolation for digital input signals.

Output Auxiliary Relay Assembly 216GA61

Up to 16 auxiliary relays providing full potential separation for digital output signals (two contacts per signal).

Trip Auxiliary Relay Assembly 216GA62

Provides up to 8 powerful potential-free trip contacts and circuits that provide high-speed operation (surge circuits) and reduced consumption after operation (economy circuits).

The Trip Auxiliary Relay Assembly is available with an optional trip logic diode matrix for direct coupling of external signals.

Matrix for direct coupling of external signals The REG216 can also read and process external signals via digital inputs.

Different trip circuit monitoring arrangements for use with output unit 216DB61 and input auxiliary relay assembly 216GE61 are available.

ABB REF610 Feeder Line Protection Relay Product Overview

Product overview

3.1 Purpose of the relay

The feeder protection relay REF610 is a multifunctional protection relay primarily used to protect incoming and outgoing lines in various feeder applications.

The relay is based on a microprocessor environment. A self-monitoring system continuously monitors the operation of the relay.

The human-machine interface includes a liquid crystal display (LCD) that makes local use of the relay safe and easy.

The relays can be controlled locally via serial communications from a computer connected to the front communication port.

Remote control is available through a serial communications bus connected to the rear connector of the control and monitoring system.

3.2. Features

* Three-phase non-directional overcurrent protection with timing or IDMT characteristics and low rectification phase.

* Three-phase non-directional overcurrent protection, high rectification phase

* Three-phase non-directional overcurrent protection, instantaneous stage

* Non-directional ground fault protection with timing or IDMT characteristics, low setting stage

* Non-directional ground-fault protection, high-calibration phase.

* Phase discontinuity protection

* Three-phase cable thermal overload protection

* Arc protection

* Two lens sensors for arc detection (optional)

* Automatic adjustment of reference level according to backlight intensity

* Arc detection by remote light signal

* Automatic reclosing 1…. .3 times

* Circuit breaker fault protection

* Trip counter for circuit breaker status monitoring

* Trip circuit monitoring with routing of warning signals to signal outputs

* Trip lockout function

* Four accurate current inputs

* User selectable rated frequency 50/60 Hz

* Three normally open power output contacts

* Two change-over signaling output contacts and three additional change-over signaling output contacts on optional I/O module

* Output contact functions can be freely configured according to requirements.

ABB REF610 Feeder Line Protection Relay Technical Description

Self-Monitoring

The relay’s self-monitoring system manages fault conditions during operation and notifies the user of existing faults.

There are two types of fault indications

Internal Relay Fault (IRF) indication and warning.

When the self-monitoring system detects a permanent internal relay fault and prevents the relay from operating, the green LED (Ready) will flash.

At the same time, the normally open IRF contact (also known as the IRF relay) will open and a fault code will be displayed on the LCD. The fault code is numeric and identifies the type of fault.

Time Synchronization

Time synchronization of the relay real-time clock can be achieved in two different ways

Serial communication via communication protocol or via digital input.

When time synchronization is achieved via serial communication, the time is written directly to the relay’s real-time clock.

Any digital input can be configured for time synchronization and used for minute pulse or second pulse synchronization.

The synchronization pulse is automatically selected, depending on the time range in which the pulse occurs.

Two pulses need to be detected within an acceptable time range before the relay activates pulse synchronization.

Conversely, if the synchronization pulse disappears, the relay requires the equivalent of four pulse time ranges to de-synchronize the pulse.

The time must be set manually once via serial communication or the HMI.

When setting the time via serial communication and using minute pulse synchronization, only the year-month-day-hour-minute is written to the relay’s real-time clock;

When using seconds pulse synchronization, only year-month-day-hour-minute-second is written. The relay’s real-time clock will round to the nearest whole second or whole minute.

depending on whether seconds pulse synchronization or minutes pulse synchronization is used. When setting the time via the HMI, the entire time will be written to the relay’s real-time clock.

If the difference between the synchronization pulse and the relay’s real-time clock for seconds pulses exceeds ±0.05 seconds, or for minutes pulses exceeds ±2 seconds, the synchronization pulse will be rejected.

Time synchronization is always triggered on the rising edge of the digital input signal. The time is adjusted by accelerating or decelerating the relay clock.

In this way, the clock neither stops nor jumps suddenly during time adjustment.

Typical accuracy of time synchronization via digital inputs is ± 2.5 ms for second pulse synchronization and ± 5 ms for minute pulse synchronization.

IC694MDL940 PAC System RX3i Discrete Output Module

The IC694MDL940 is equipped with sixteen (16) status LEDs, each representing an individual channel.

The energized LEDs indicate energized outputs and the de-energized LEDs indicate other outputs.

The module does not have a built-in mounted fuse for channel protection; therefore, the user may need to install an external fuse to protect the module.

This IC694MDL940 has 250 VAC continuous and 1500 VAC (1-minute isolation rating) from field to backplane and frame to ground.

And channel-to-channel isolation is 250 VAC continuous; 1500 VAC for 1 minute.

The GE Fanuc IC694MDL940 Relay Output Module is a 3-channel relay output module designed specifically for the RX16i PACSystems PLC system.

The IC694MDL940 output module provides 16 independently isolated normally open output circuits for controlling output devices such as motor starters, solenoids, and indicator lights.

Each IC694MDL940 output module has a maximum switching capacity of 2 amps at the output point, and they are divided into 4 non-isolated groups of 4 output channels each.

Each output group of the IC694MDL940 output module has a common output terminal (total of 4 output terminals per module).

Each internal relay output point is powered from a 24 Vdc backplane power supply. An external AC/DC power supply must be ordered and installed separately to power the connected output field devices.

The IC694MDL940 Output Module is rated for 24 VDC or 120/240 VAC.

The operating range is 5 to 30 volts DC or 5 to 250 volts AC (50/60 Hz).

The IC694MDL940 output module has a maximum point-to-point isolation of 1500 VAC for 1 minute and 250 VAC.

Continuous isolation between field and backplane and between frame grounds. The minimum possible load on the output circuit of each IC694MDL940 output module is 10 milliamps.

The maximum load on each output point is 2.0 amps, and each set of common loads is 4.0 amps.

The IC694MDL940 Output Module draws up to 5.0 mA of backplane current at 7.0 volts DC on the backplane.

The IC694MDL940 output module draws up to 5.0 milliamps of backplane current at 7.0 volts DC on the backplane and up to 24 milliamps at 135 volts DC relay bus voltage. There are 32 LEDs on the front panel of the module to indicate the on or off status of each output channel.

The IC694MDL940 output module is compatible with RX3i PacSystems CPUs only and can be installed in any I/O slot on the RX3i PacSystems PLC backplane.

IC694MDL930 Relay Output Module

The module’s maximum backplane current draw is 6 mA, and all outputs are energized by a 5 VDC bus on the backplane.

All outputs are energized by a relay 70VDC bus on the backplane and the maximum backplane current consumption is 24mA.

The module also supports mounting to 90-30 series backplanes. It can be used as a local output module, mounted on a central processing unit (CPU) chassis, or with an appropriate communications adapter.

It can also be mounted on an extended remote distributed I/O station with appropriate communication adapters.

It is classified as a high voltage module and has eight (8) status LEDs to characterize the energized state of each output channel.

The module does not come with channel protection such as fuses or RC buffer circuits.

The IC694MDL930 RX3i is a 3-channel relay output module for the GE Fanuc RX8i PACSystems discrete I/O PLC series.

As with every discrete output module in the series, the IC694MDL930 output module is used between the RX3i PLC and external output devices such as indicators and motors.

(Like every discrete output module in the series, the IC694MDL930 Output Module provides an interface between the RX3i PLC and external output devices such as indicator lights, motor starters, and solenoids.

Each output point is capable of switching loads up to 4.0 amps, and each output point has its own common output terminal.

The IC694MDL930 Output Module requires an external power supply to operate and can be ordered in either AC or DC ratings of 120 to 240 volts AC or 24 volts DC.

Users can order AC or DC power modules rated from 120 to 240 volts AC or 24 volts DC to operate all connected field devices.

The IC694MDL930 output module operates from 5 to 30 volts DC or 5 to 250 volts AC (50 to 60 Hz).

Output point-to-point isolation is rated at 250 volts AC continuous or 1500 volts AC for 60 seconds.

The IC694MDL930 output module has eight independently isolated normally open relay-type outputs with a maximum output current load of 4.0 amps per point.

The maximum output current load per module is 20.0 amps. The IC694MDL930 output module has a maximum backplane current draw of 5.0 milliamps at 6.0 volts DC.

The minimum output load is 10.0 milliamps per point.The IC694MDL930 output module has an inrush current rating of 5.0 amps max.

The IC694MDL930 output module has a maximum inrush current rating of 5.0 amps and a maximum response time of 10 milliseconds (on or off). 32 individually numbered LEDs indicate the individual operation of each output point.

The IC694MDL930 output module has 32 individually numbered LEDs to indicate the individual operating status of each output point, and the entire module can be mounted in the I/O slots on the RX3i PLC backplane.

IC200ALG262 8-Point Analog Current Input Module for VersaMax I/O Series

The IC200ALG262 is a component module of the VersaMax I/O platform. It is an analog input module designed to support differential current wiring.

It has eight (8) analog input channels designed to receive standard current input signals such as 0-20 mA and 4-20 mA input signals.

This IC200ALG262 is currently manufactured by Emerson Automation. It is ideally suited for connection to analog signal generating instruments such as field transmitters.

for measuring pressure, level, flow, temperature, turbidity, viscosity, speed, and other types of transmitters; for integrating locally mounted panel meters to

remote display; for monitoring the speed output of variable frequency drives (VFDs); for monitoring the position of rotary and linear devices; and other applications.

The IC200ALG262 has a built-in analog-to-digital converter (ADC) circuit with 15-bit conversion resolution. The input channels are arranged in groups.

When configured to receive 4-20 mA, they are capable of detecting power loss and open circuit detection within the module. Each channel has an uplink rate of 7.5 ms.

Each channel has an uplink rate of 7.5 ms and a digital resolution of 0.5 μA (4-20 mA signal range) and 0.625 μA (0-20 mA signal range). The module has a maximum backplane current consumption of 5 mA at 200 VDC bus voltage.

Compatible configuration software and hardware firmware versions that can be used with this module include VersaPro software version 2.0 or later; VersaMax PLC CPU CPU version 2.0 or later; and VersaMax PLC CPU version 2.0 or later.

IC695RMX128 PACSystems RX3i Redundant Memory Switch Module

​This IC695RMX128 is a PACSystems RX3i redundant memory switching module manufactured by Emerson Automation (formerly GE Intelligent Platforms (GE IP)).

The module has 128MB of SDRAM user memory and supports operation as a reflective memory network or dedicated link between RX3i CPUs in a redundant configuration.

The module comes with single-mode fiber that supports 2.12 Gbaud fiber networks.

About the IC695RMX128

The IC695RMX128 is the PACSystems RX3i Redundant Memory Exchange Module.

The primary function of the module is to act as a single node on a reflective memory topology or as a dedicated memory module for redundant RX3i CPU pairs.

When used in a redundant CPU configuration, the IC695RMX128 reflects the contents of the IC695CMX128.

With a reflected memory link, any updates on one node are reflected and updated to all other nodes connected to the same network.

Connections are established over a fiber optic network supporting up to 256 nodes.

The module is equipped with 128 MB of reflective memory, and the fiber optic power supply requires an LC-type connector for transmission speeds up to 2.12 Gbaud.

The module operates on supplies of 580 mA @ 3.3 VDC and 220 MA @ 5 VDC.

ABB REF620 IEC Feeder Protection and Measurement Control Unit

Main advantages

Devices can be used for a wide range of applications

Ranging from simple protection devices as backup protection to specialized protection devices

Well-established and modernized technology

Arc detection as an option

REF620 as a dedicated feeder protection device for the protection, control, measurement and monitoring of public and industrial power distribution systems.

REF620 IEC feeder protection and measurement and control device, as a dedicated feeder protection device, is specially designed for the protection, control, measurement and monitoring of public and industrial grids, including radial, ring and mesh grids.

The REF620 provides feeder overcurrent and earth fault protection that can be applied to both ungrounded neutral networks and resistance or impedance neutral grounded networks.

In addition, utilizing the unit’s advanced station-to-station communication capabilities, the REF620 can also be used for ring mesh distribution network or radial network protection.

The REF620 IEC Feeder Protection and Measurement Control Unit is available in single and dual busbar configurations, with one or two circuit breakers and multiple switchgear configurations for each busbar configuration.

The unit supports a large number of manual and motorized disconnect and ground switches. The number of available I/Os can be increased as required by ABB’s RIO600 remote I/O unit.

The REF620 IEC Feeder Protection and Control Unit features support for the IEC61850 communication standard for substations, covering both vertical and horizontal communications.

It includes GOOSE telegrams with switching and analog signals, and constant value adjustment based on IEC 61850-8-1.

The REF620 also supports DNP3. IEC 60870-5-103 and Modbus® protocols.

The REF620 provides an optional Ethernet port for non-delayed redundant Ethernet or a ring self-healing RSTP communication in the event of a communication failure via PRP or HSR protocols.

This solution eliminates the effects of a single point of failure and improves communication reliability. The solution can be applied to Ethernet based IEC 61850. Modbus® and DNP3 protocols.

Honeywell FC-SAI-1620M Safety High Density Analog Input Module

Introducing:

Honeywell Safety Manager™ is a reliable and highly complete safety system tailored for critical control applications.

It is an integral part of Honeywell Experion™ PKS and integrates seamlessly into PlantScape and can also operate autonomously.

Safety Manager is the foundation of functional safety, ensuring the well-being of individuals, plant assets and the environment while optimizing plant continuity.

Safety Manager is a user-programmable, modular, microprocessor-based safety system capable of performing a wide range of high integrity process control and safety instrumentation functions, including:

High integrity process control

Burner/boiler management systems

Process protection and emergency shutdown

Turbine and compressor safety protection

Fire and gas detection systems

Pipeline monitoring

Enhanced business results:

Safety Manager™ is an evolution of the proven Fail Safe Controller (FSC®) safety system platform that has been globally recognized for more than 15 years.

It embodies proven technology backed by Honeywell’s two decades of expertise in process safety management. This includes the integration of process safety data, applications, system diagnostics and critical control strategies.

Safety Manager is designed to enhance business performance, improve process safety and protect plant assets and people.

The safety system is seamlessly integrated with the Experion™ Process Knowledge System (PKS) into a single architecture, providing an excellent opportunity to improve safety and process availability.

Experion PKS ensures unparalleled connectivity between processes and business operations, optimizes workflows, simplifies maintenance tasks, enhances safety management, and frees personnel from manual tasks.

Search for products

Back to Top
Product has been added to your cart