The safety-relevant parameters are transferred to the new component when
the safety application is restarted.
A further highlight of the EL1918 is the integration of the functionality of the
EL6910 TwinSAFE Logic. The EL1918 can also be used as a safety controller
at any time. In the default case, the EL1918 is a simple input terminal,
whose input signals are transmitted via FSoE to a TwinSAFE Logic-capable
component. It can be used directly as a safety controller in order to process
input signals directly in the terminal so as to forward only accumulated
information to a TwinSAFE Logic, or a complete safety application can be
implemented on the EL1918. The range of functions corresponds to that of
the EL6910. The only difference is the limitation of the number of possible
safe connections to 128. Apart from that, all the advantages of the new
generation of safety controllers can be used (see EL6910 customizing,
incremental download, analog value processing, etc.).