The EL1918 TwinSAFE component is a digital input terminal for sensors
with potential-free contacts for 24 V DC. The EtherCAT terminal has eight
fail-safe inputs, which are transmitted via FSoE to a TwinSAFE Logic-capable
component.
The EL1918 has safety parameters to specifically adapt the functionality to
the respective safety requirements. Thus, for example,test pulses can be
configured with fine granularity for all eight channels in order to be able
to connect as many types of sensors as possible.
The safety parameters are not stored directly on the component, but are
transmitted to the input terminal via a TwinSAFE Logic capable component
when the safety application is started. This simplifies service procedures,
because the component can simply be replaced.
Special features EL1918:
• 8 safe inputs
• integrated TwinSAFE Logic (functionality similar to the EL6910)
• up to 128 safe connections
• fine granular configuration of the test pulses of the individual channels
For applications without integrated TwinSAFE Logic, the EL1918-2200 can
be used.
Special features EL1918-2200:
• 8 safe inputs
• fine granular configuration of the test pulses of the individual channels
• TwinSAFE Logic not integrated