Features

• IEEE 1686 Standard Password Compliant Cyber Security

• IPsec (Internet Protocol Security)

• RADIUS Client Capability to manage local and remote access to the control

• Adjustable Bandcenter

• Adjustable Bandwidth

• Adjustable VAr Bias

• Line Drop Compensation, R, X and Z Compensation

• Time Delay, Definite and Inverse

• InterTap Time Delay

• Four Settings Profiles

• Compare Settings Tool

• Selectable Outputs, Continuous or Pulsed

• Reverse Power Operation for Single-Phase Regulator applications

• Real-Time Metering of measured and calculated parameters

• Demand Metering with selectable time interval

• Drag Hands Operation

• Adjustable Line Overcurrent Tapchange Inhibit

• Voltage Limits

• Tap Position Limits

• Auto Runback (due to overvoltage)

• Three Independent Voltage Reduction Steps

• Sequential and Non-Sequential Operation

• SCADA Heartbeat

• Manual Heartbeat Timer

• VT Ratio Correction

• Tap Position Knowledge by Motor Direct Drive KeepTrack method

• Operations Counter

• Resettable Operations Counter

• Harmonic Analysis

• Tap Position Record

• Auto/Off/Manual Switch Status

• A or B Regulator Type Selection

• User Programmable Alarm/Deadman Contact

• SCADA Cutout (Local/Remote) switch allows blocking of write commands

from COM1. COM2 or Ethernet

• Control Voltage Input

• Source Side PT Input

• Motor Power Input

• Load Current Input

• Raise Output

• Lower Output

• 20 Character by 2 Row LED backlit LCD Display

• TapTalk S-6200 Communications Software

• USB (1.1) Communications Port

• Motor Current Profiling

• Up to 30 unique 15 character User Access Codes (Level 1 or Level 2)

• CBEMA monitoring to detect sags and swells within a range of 90 Vac to

180 Vac, and trigger data collection and alarming functions

• VAr Bias (Step and Linear Methods)

• Smart Flash SD Card Slot supports standard SD Memory Cards: SD, SDHC,

SDXC, UHS-I

• Smart Flash SD Card can be linked to one or multiple controls providing a

physical security “Key” which provides User Access Level 2 Access to the

control when the SD Card is inserted for settings manipulation

• Sequence of Events (SOE)

• Data Logging

• Oscillography

• External Inhibit of Auto Tapchange

• Front Panel LEDs for Out-of-Band RAISE, Out-of-Band LOWER, Auto Operation

Block MANUAL, SCADA Control blocked LOCAL, CPU OK, ALARM active, REVERSE

POWER Flow detected, VOLTAGE REDUCTION in effect, NEUTRAL LIGHT, and

TX/RX Activity on Com1

• Voltage Reduction 1 & 2 Inputs (Binary)

• Neutral Position Detect and Counter

• Counter Input (Binary)

• Motor Seal-In Input (Binary)

• Motor Seal-In Failure Alarm and Block

• Non-Sequential Input (Binary)

• COM1. RS-485 (two-wire), RS-232. or Serial Fiber (Specify)

• Communication Protocols include MODBUS, Secure DNP3.0 (Authentication)

and Cooper 2179

• Control Power Back-Up Input – input (+12 Vdc) for backup of Fiber Optic loop

through communication

• One set (3) of spare fuses are included

• Supports Station and Feeder Level DNP addressing in addition to individual

addressing for Smart Grid applications

• One pushbutton access to user configurable Wakeup screen for manual data

recording with Smart Flash SD Card saving feature

• Run Through Neutral, Automatic Reversing Switch swiping

• Individual Tap Wear Alarm

• User selectable Tapchanger Type