Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Emerson PACSystemsTM RX3i I/O Provides Advanced Diagnostics

The Perfect Upgrade Path

Emerson’s RX3i gives you a simple migration path from the 90-30 Series,

90-70 Series, and RX7i Series legacy systems in a fast, hassle-free upgrade program.

RX3i allows you to reuse 90-30 series modules on RX3i backplanes, so you can upgrade your I/O system without having to mess with wiring or buy I/O modules.

As a result, you can upgrade your I/O system without messing with wiring or buying new I/O.

Upgrading to the RX3i improves integrated Ethernet and modern USB communications for serial or memory stick.

With a smaller form factor, greater capacity, and speeds more than 100 times faster than traditional control devices, the RX3i is an easy, cost-effective way to upgrade.

Protect your investment without disruption. Upgrades take hours, not days!

High Availability

Eliminate process disruption with RX3i I/O. In addition to providing high performance in simplex configurations,

the RX3i is available in high-availability configurations for maximum reliability.

It supports Ethernet Global Data (EGD) and PROFINET System Redundancy (PNSR).

With gigabit speeds and bufferless switching, choose RX3i High Availability to avoid unexpected failures and costly downtime.

Ruggedized connector terminals

In the RX3i series, all I/O modules are equipped with removable terminal blocks for easy commissioning and maintenance.

This emphasis on ease of use is also reflected in the range of wire gauges supported.

Depending on the terminal type selected, the wire gauge range is 0.081mm2 – 1.5mm2 (28 – 14AWG) solid or stranded wire.

Both spring-loaded and cassette modules are available for your preferred connection method.

Both low and high density terminals support Terminal Block Quick Connect (TBQC) and positive retention

to ensure wiring stability and a consistent commissioning experience.

Emerson CSI 6500 ATG Protection System View Problems in Real Time

View Problems in Real Time

The system comes with ATG View, a mobile application that receives data from the CSI 6500 ATG via Ethernet and/or a wireless router.

Authorized users can view protection status and health data from anywhere

on the plant’s Wi-Fi network, either from a PC or a device of their choice.

Supported devices include Apple iOS and Android phones and tablets.

The ATG view allows reliability professionals to see the overall health of the system,

alarm status, external inputs such as bypasses and outputs such as trips and whether they are active.

The CSI 6500 ATG displays all available information for critical devices, such as primary values,

trending data, status data, and predictive data (e.g., PeakVue values).

Studies have shown that repairing a machine after it has failed is 50% more costly

than predicting failure and planning for the cost of repair.

For users whose budgets are not large enough to purchase both a protection system and a predictive system,

obtaining predictive data from the protection system is an incremental step toward improving insight into the health of assets.

ATG View provides asset health information to users anywhere in the plant network.

Emerson CSI 6500 ATG Protection System Features

Familiar Features

System setup is accomplished through Machine Studio configuration software.

The user interface has a similar look and feel to other Emerson software modules, making it familiar and easy to use.

Familiar and easy to use. While connected, users can access integrated predictive features.

OPC server helps you integrate with third-party systems

For easy integration with third-party systems, the CSI 6500 ATG is the first protection

system to include a secure embedded OPC UA server.

The CSI 6500 ATG system meets traditional API 670 certification and is certified

for installation in demanding environments that require Class 1 Div2/ATEX Zone 2 certification.

Studies have shown that repairing a machine after it has failed is 50% more costly

than predicting failure and planning for the cost of repair.

For users whose budgets are not large enough to purchase both a protection system and a predictive system,

obtaining predictive data from the protection system is an incremental step toward improving insight into the health of assets.

ATG View provides asset health information to users anywhere in the plant network.

Emerson Ovation™ Power System (5X00785G09) solution

Redundant Power Configuration (Primary and Auxiliary) includes separate 10 Amp Primary and Auxiliary

power supplies supporting multiple input voltages (85-264 VAC @ 43-67 Hz or 90-375 VDC) with 240 W output power.

A power distribution module distributes the diode auction output to the controller and I/O bus.

The 10 Amp solution includes a backplane with pre-installed DIN rails on which the power distribution module,

circuit breakers, and four 10 Amp power supplies are mounted.

The 10 Amp power supplies have a life expectancy of 8 years (40°C).

20 Amp Power Supply Solution

The 20 Amp power supply solution includes

Redundant power configurations (primary and auxiliary) containing independent 20 A primary and auxiliary power supplies

supporting a wide range of input voltages (85-264 VAC @ 43-67 Hz or 90-375 VDC) with 480 W output power.

Auction diodes to ensure continuous power

Emerson Ovation™ Power System (5X00785G09) Benefits

Benefits

Benefits of Ovation power solutions include

Separate primary and auxiliary power supplies are easy to replace

No cooling fan required, greatly reducing the risk of failure

Diode auction feed ensures continuous power

New design improves efficiency, reduces heat generation and extends equipment life expectancy

Dual input (AC and DC) capability reduces spare parts

Hot-swappable power supplies enable in-line replacement

Quick installation of power supplies minimizes downtime and lost production

Power factor correction reduces power consumption

10 Amp Power Solutions

10 Amp power supply options include

Power Distribution Terminal Block

The 20 Amp Power Solution consists of a backplane with pre-installed DIN rails on which the distribution

terminal block,auction diodes, circuit breakers, and four 20 Amp power supplies are mounted.

The 20 Amp Power Solution increases the power of Ovation controllers and input/output devices to 480

Watts.The 20 Amp power supplies have a life expectancy of 15 years at 40°C and a 10 Amp load.

Emerson Ethernet I/O Card (EIOC) Modular and Easy to add Redundancy

„ Modular and Easy to add Redundancy. The dual horizontal

carrier hosts all the needed components for a redundant

setup (redundant Power input Terminals and redundant

Ethernet Isolation ports). The EIOC becomes redundant

just by adding a second EIOC on the dual horizontal

carrier. The configuration will change automatically,

confirming that the two EIOCs are now working as a

redundant pair. Manual switchovers can be controlled

in DeltaV Diagnostics Explorer. The redundant Ethernet

ports provide isolation between DeltaV Control Network

communication and the redundant Ethernet Device Network.

The EIOC also implements Parallel Redundant Protocol

(PRP) for an added layer of robustness, providing a seamless

switchover between primary and secondary networks.

Emerson Ethernet I/O Card (EIOC) Easy to use

„ Easy to use. The EIOC is easy to use as it provides a native

way to bring Ethernet protocol data into the DeltaV system.

Specific ease of use features include:

• You can choose between the 5 different Ethernet

protocols supported in the EIOC. Only one protocol is

supported at a time and requires the proper licensing.

• Updates for the EIOC and drivers are included

within DeltaV.

• Configured in DeltaV Explorer. All needed configuration

for the Ethernet Devices is done in DeltaV Explorer and

DeltaV Control Studio, just like Traditional I/O signals.

The data can be configured in DeltaV Control Modules,

displayed on DeltaV Live and DeltaV Operate graphics,

and stored in the DeltaV Continuous Historian.

Emerson Ethernet I/O Card (EIOC) Huge processing capacity

„ Huge processing capacity. Each EIOC is capable of handling

a huge amount of Data in up to 2000 Control Modules.

„ EIOC is part of the DeltaV Control Network. 60 EIOC’s

can be added directly to the DeltaV Control Network,

allowing maximum freedom in segregating your networks.

„ Flexible networking. User configurable IP addressing for

the Ethernet Device Network allows the EIOC to be used in

almost any plant environment regardless of the networking

scheme. When designing a simplex Ethernet Device Network,

consider that the EIOC and the Ethernet Devices must be on

the same IP subnet to communicate. Also, when designing

a redundant Ethernet Device Network, consider that the

primary and secondary ports in the EIOC must be in different

subnets to follow best engineering practices.

Emerson Ethernet I/O Card (EIOC) Monitoring

„ Monitoring. Data values integrated into the EIOC can

be used in Control Modules running inside the EIOC.

These control modules allow alarm generation,

history collection, and viewing by the operator,

as with control modules running in a Controller

using traditional DeltaV native I/O.

„ Supports control functionality. In addition,

function blocks allowing for discrete control and limited

PID control are supported for the EIOC. No assignment to a

controller is required. Motors, switchgear, variable frequency

drives; or any device that communicate via Ethernet

protocols can be controlled directly from the EIOC.

„ Easy to connect to Ethernet Devices using Modbus TCP,

EtherNet/IP, IEC61850 MMS, OPC UA client and EtherNet/

IP Control Tag Integration protocols. Use the EIOC Ethernet

protocols to connect your DeltaV system to your Ethernet

Device Networks.

Emerson Ethernet I/O Card (EIOC) Powerful and Scalable

Benefits

Ability to communicate directly to Ethernet Device

Networks. Use the EIOC to monitor and control

Ethernet Devices.

„ Powerful and Scalable. The EIOC allows a huge amount of

data coming from Ethernet Devices to be accessed in DeltaV,

and is scalable to fit your needs with licensing based on the

number of devices you connect. The EIOC can bring:

• Up to 32,000 signals from 256 Ethernet Devices when

using Modbus TCP, EtherNet/IP, or IEC61850 MMS.

• Up to 30,000 signals from 64 Ethernet Devices when

using OPC UA client protocol.

• Up to 2000 tags (10 signals per tag) from 256 Ethernet

Devices when using EtherNet/IP Control Tag

Integration Protocol.

Search for products