Welcome to the official website of CNIACS Automation Technology Co., Ltd!

CTI 2572-A Fast Ethernet TCP/IP Adapter

The 2572-A Ethernet TCP/IP Adapter is the next generation

2572 network interface module for 2500 Series® or Simatic®

505 controllers. The 2572-A provides connectivity to Ethernet

networks using IEEE 802.3. Ethernet II and Transmission

Control/Internet Protocol standards, at 10M or 100M speeds.

IMPORTANT NOTE: 2572-A HAS BEEN MATURED.

IT IS REPLACED BY 2572-B or 2500P-ECC1.

WHICH SHOULD BE USED ON ALL NEW DESIGNS.

Features

• Compatible with Siemens® 505-CP2572 and CTI 2572

• Auto-sensing for 10/100Mbps networks

• TCP/IP support includes UDP and TCP

• Supports Modbus-TCP and Ethernet/IP protocols

• Remote programming over Ethernet

• MMI/HMI connectivity

• DDE and OPC support available

• DHCP configuration option

• Built-in web server for diagnostics

CTI 2572-A Application Notes

Application Notes

• Guide for Converting Ethernet Applications from 2572 /

2572-A / 2572-B to 2500P-ECC1

• Setting the IP address using the PLC on 2572-A and

2572-B (Tech Tip)

• 2572 Installation and Setup Instructions

• Assigning an IP Address to the 2572-A without Connecting

to the Module

• Communication to Simatic S7 Using Open Modbus

• Creating a Client/Server Memory Transfer between Two

2572-X Modules

• Getting Started with Networking and the 2572

• Reading Values into Excel Spreadsheets Using the 2572

• Replacing a Peerlink Network with Ethernet and 2572-A

• Using CTIDIAG with the 2572

• Using the 2572 UDP “Send To” Feature to Exchange Memory

with Multiple PLCs

• Using the 2572 with Wonderware 7.0

• IP Addressing and the 2572

• Starting the 2572 Network Server from PLC Logic

CTI 2572-B Fast Ethernet TCP/IP Adapter

The 2572-B Fast Ethernet TCP/IP Adapter is the next generation Ethernet

network interface module for 2500 Series® or Simatic® 505 controllers.

The 2572-B provides connectivity to Ethernet networks using IEEE 802.3.

Ethernet II and Transmission Control/Internet Protocol standards, at 10M

or 100M speeds.

For help selecting the right Ethernet solution for your needs, see our

Tech Tip:

Ethernet Communications: What is the Best Solution for Your Needs?

or click on the link below to get help from an Applications Engineer.

Get Help With Ethernet

Features

• Direct replacement for 2572-A

• Compatible with CTI 2572-A, CTI 2572. and Siemens® 505-CP2572

• New IP address display on front panel

• No serial connection required to set IP address

• DHCP address switches eliminated (contact CTI if your application

uses DHCP)

• Auto-sensing for 10/100Mbps networks

• TCP/IP support includes UDP and TCP

• Supports Modbus-TCP and Ethernet/IP protocols

• Remote programming over Ethernet

• MMI/HMI connectivity

• DDE and OPC support available

• Built-in web server for diagnostics

CTI 2500S-27-1050 Features

Features

• I/O configuration of 2DIO / 4UAI / 2AI

• RJ45 Ethernet port

• Connects to CTI and legacy Siemens® /TI CPUs over Ethernet

• Several models with differing I/O capabilities allow you to customize

the solution to your needs

• Extensive intelligent features for processing attached I/O signals:

– Totalization, filtering, forcing, inversion, runtime, and counting on

digital inputs

– Frequency out (with PWM) and synchronization on digital outputs

– Filtering, averaging, scaling and totalization on analog inputs

– Data logging and trending

• All module configuration done using a simple web browser interface

• Wide –40°C to +70°C operating temperature range

CTI 2500S-27-1050 Slice I/O, Ethernet, 2DIO / 4UAI / 2AI (MATURE)

The 2500S family of Slice I/O modules expands the capability of 2500

Series® Systems to include small drops of I/O connected over Ethernet.

Slice I/O modules communicate to 2500 Series® Processors using CAMP

protocol and read/write directly to the PLC memory or I/O image table.

This allows transparent integration into the 2500 Series® system without

the requirement for any complicated configuration step.

Ethernet connection to the CPU can be accomplished using the on-board

port on 2500-Cxxx Processors, or using a 2572 / 2572-A Ethernet module.

Note that when using 2572 or 2572-A modules, Slice I/O can be connected

even to legacy Siemens® and Texas Instruments PLCs.

Several models of Slice I/O are available with different mixes of I/O and with

additional communications options including RS232/485 and 900MHz radio.

Slice I/O modules feature Universal Analog Inputs which allow connection

of 0-5V, 0-20mA, thermocouple, and RTD sensors. All Slice I/O modules can

also be configured to communicate over Ethernet using Modbus-TCP.

Note: This unit is designed to work on a battery so +12VDC is operating

voltage, not +24VDC.

NOTE: THIS PRODUCT IS MATURE AND IS  NO LONGER AVAILABLE FOR

PURCHASE.

CTI 2500S-26-1050 Features

Features

• I/O configuration of 8DIO / 2UAI

• RJ45 Ethernet port

• Connects to CTI and legacy Siemens® /TI CPUs over Ethernet

• Several models with differing I/O capabilities allow you to customize

the solution to your needs

• Extensive intelligent features for processing attached I/O signals:

– Totalization, filtering, forcing, inversion, runtime, and counting on digital inputs

– Frequency out (with PWM) and synchronization on digital outputs

– Filtering, averaging, scaling and totalization on analog inputs

– Data logging and trending

• All module configuration done using a simple web browser interface

• Wide –40°C to +70°C operating temperature range

CTI 2500S-26-1050 Slice I/O, Ethernet, 8DIO / 2UAI (MATURE)

The 2500S family of Slice I/O modules expands the capability of 2500

Series® Systems to include small drops of I/O connected over Ethernet.

Slice I/O modules communicate to 2500 Series® Processors using CAMP

protocol and read/write directly to the PLC memory or I/O image table.

This allows transparent integration into the 2500 Series® system without

the requirement for any complicated configuration step.

Ethernet connection to the CPU can be accomplished using the on-board

port on 2500-Cxxx Processors, or using a 2572 / 2572-A Ethernet module.

Note that when using 2572 or 2572-A modules, Slice I/O can be connected

even to legacy Siemens® and Texas Instruments PLCs.

Several models of Slice I/O are available with different mixes of I/O and

with additional communications options including RS232/485 and 900MHz

radio. Slice I/O modules feature Universal Analog Inputs which allow

connection of 0-5V, 0-20mA, thermocouple, and RTD sensors.

All Slice I/O modules can also be configured to communicate over Ethernet

using Modbus-TCP.

Note: This unit is designed to work on a battery so +12VDC is operating

voltage, not +24VDC.

NOTE: THIS PRODUCT IS MATURE AND IS  NO LONGER AVAILABLE FOR

PURCHASE.

CTI 2500S-23-1050 Slice I/O, Ethernet, 4DI / 4DO / 2UAI / 2AO (MATURE)

The 2500S family of Slice I/O modules expands the capability of 2500 Series®

Systems to include small drops of I/O connected over Ethernet.

Slice I/O modules communicate to 2500 Series® Processors using CAMP protocol

and read/write directly to the PLC memory or I/O image table.

This allows transparent integration into the 2500 Series® system without the

requirement for any complicated configuration step.

Ethernet connection to the CPU can be accomplished using the on-board port

on 2500-Cxxx Processors, or using a 2572 / 2572-A Ethernet module.

Note that when using 2572 or 2572-A modules, Slice I/O can be connected

even to legacy Siemens® and Texas Instruments PLCs.

Several models of Slice I/O are available with different mixes of I/O and with

additional communications options including RS232/485 and 900MHz radio.

Slice I/O modules feature Universal Analog Inputs which allow connection of

0-5V, 0-20mA, thermocouple, and RTD sensors.

All Slice I/O modules can also be configured to communicate over Ethernet

using Modbus-TCP.

NOTE: THIS PRODUCT IS MATURE AND IS  NO LONGER AVAILABLE FOR

PURCHASE.

CTI 2500S-23-1050 Features

Features

• I/O configuration of 4DI / 4DO / 2UAI / 2AO

• RJ45 Ethernet port

• Connects to CTI and legacy Siemens® /TI CPUs over Ethernet

• Several models with differing I/O capabilities allow you to customize

the solution to your needs

• Extensive intelligent features for processing attached I/O signals:

• – Totalization, filtering, forcing, inversion, runtime, and counting on

digital inputs

• – Frequency out (with PWM) and synchronization on digital outputs

• – Filtering, averaging, scaling and totalization on analog inputs

• – Data logging and trending

• All module configuration done using a simple web browser interface

• Wide –40°C to +70°C operating temperature range

CTI 2500-VP15A-N4-W7 15″ Flat-Panel PC with Windows® 7 Embedded

2500 Series® Flat-Panel PCs make a good platform for integrating your

own Windows® based HMI applications into 2500 Series® Systems.

The panels are based on the latest Intel® Atom™ processor technology

and feature a high-brightness LCD panel for easy readability under

industrial conditions IMPORTANT NOTE: THIS PRODUCT WAS MATURED

ON APRIL 1. 2020 AND SHOULD NOT BE USED FOR NEW DESIGNS.

Features

• CPU Intel® Atom™ N2600 1.6GHz

• Memory 2GB DDR2 SDRAM

• Network 2 x Realtek RTL8111B 10/100/1000Base-T

• USB 2.0 – 5 ports

• Serial – 4 ports

• Storage CFast Card Socket with 32GB

• LCD Display 15″ TFT LCD Resolution 1024 x 768

• XGA Backlight Life 50.000 hours

• Luminance 400 cd/sq-m

• Touch Screen 5-wire, resistive

• Other Ports PS2 Keyboard and Mouse

• Operating temp 0C to +55C

• Mechanical Dimensions 390 x 52.3 x 310mm 15.35 x 2.06 x 12.2 in

• Windows® 7 Embedded

Files & Documents

• Product Maturity Announcement

• Product Bulletin

Manuals

• User Manual 

Search for products

Back to Top
Product has been added to your cart