CTI 2559-TC Specifications

Specifications

Inputs per module: 8

Thermocouple types: J, K, T, E, R, S, N, and mV

Isolation: 1500 VDC channel-to-backplane

Input overrange protection:

30 VDC or VAC continuous

120 VAC for 10 Sec

Measurement ranges:

J: -210oC to 760oC (-350oF to 1400oF)

K: -270oC to 1372oC (-450oF to 2500oF)

T: -270oC to 400oC (-454oF to 752oF)

E: -270oC to 1000oC (-454oF to 1832oF)

R: 0oC to 1768oC (32oF to 3214oF)

S: 0oC to 1768oC (32oF to 3214oF)

N: -260oC to 1300oC (-436oF to 2372oF)

mV: -55 to +55mV

Millivolt input impedance:

4.4MΩ DC, >10KΩ @60 Hz

Open Thermocouple Detect: less than 1 Sec

Data presentation:

With scaling enabled = 0 – 32000 (temp.)

-32000 to +32000 (mV)

With scaling disabled = oC or oF x10 (temp.)

-10000 to +10000 (mV)

Measurement units: Degrees C or F

selectable by module

Digital Filtering Time Constant: 80 mSec

Update time:

9 mSec all channels

Repeatability: +/-1oC, +/-2oF for all

thermocouple types

Accuracy: Types

J: +/-1oC from 0oC to 60oC

K: +/-1oC from 0oC to 60oC

T: +/-1oC from 0oC to 60oC

E: +/-1oC from 0oC to 60oC

R: +/-2oC from 0oC to 60oC*

S: +/-2oC from 0oC to 60oC*

N: +/-1oC from 0oC to 60oC

mV: +/-0.5% full scale or +/- 500μV

ADC Resolution: 16 bits

Common Mode Rejection: >110 db @ 60 Hz

Normal Mode Rejection:

>60 db @ 60 Hz, >50 db @ 50 Hz

Connector: Removable

Wire Gauge: 14-22 AWG

Backplane Power: 1.0 Watt (maximum)

Module Size: Single-wide

Operating Temperature: 0o to 60oC (32o to 140oF)

Storage Temperature: -40o to 85oC (-40o to 185oF)

Relative Humidity: 5% to 95% (non-condensing)

Agency Approvals Pending:

UL, ULC, Class 1-Div. 2. CE

Shipping Weight: 1.5 lb. (0.68 Kg)

CTI 2552-A Specifications

Specifications

Input Channels: 8 RTD input channel, independently isolated and configurable

RTD Types:

ΩTCR = 0.003850. Ω/Ω/°C

European DIN 43760

-198 °C to 849.8 °C (-327.6°F to 1561.6°F)

Ω TCR = 0.00672. Ω/Ω/oC

Temperature Range: -79.8°C to 260.0°C (-111.6°F to 500.0°F)

Other RTD types by special request: 0Ω Cu

Absolute Temp Accuracy: +0.4°C (+0.8°F)

Millivolt Range: 0 to 103.04 Millivolts

Millivolt Input Impedance: >10KΩ @ 60Hz

Absolute Millivolt Accuracy: +0.5% full scale or +500μV

Lead Compensation: 20Ω per lead wire

Bias Current to RTD Probe: 250 microamps

Digital Filtering Time Constant: 0.3 Sec

Output Units: Degrees C or F

Repeatability: 0.05% full scale

Resolution: 0.025% full scale

Update Time: 2msec per channel

Common Mode Rejection: >110db @ 60Hz (digital filtering disabled)

Normal Mode Rejection: >145db @ 60Hz (digital filtering enabled)

Input ESD Protection: 20.000V

Overrange Protection: 20 VDC input to common

Isolation: 1500V channel-to-channel

1500 VDC channel-to-PLC

Connector: Fixed 32 position terminal strip

Wire Gauge: 18-24 AWG

Backplane Power: 2.75W @ 5 VDC

Module Size: Single-wide

Shipping Weight: 1.5 lb. (0.68 Kg)

CTI 2552-A 8-Channel Isolated RTD Input Module

Description

The2552-A is a high-speed 8-channel isolated RTD input module designed to be

compatible with the CTI 2500 Series® or Simatic® 505 I/O base in local, remote I/O,

and Profibus configurations. The 2552-A translates RTD input signals into a scaled

temperature value.

Features

CTI 2500 Series® or Simatic® 505 base format

1500V channel-to-channel isolation

1500V channel-to-PLC backplane isolation

Fast 2msec update time per channel

Detects open in RTD or field wiring

Compensates for lead wire resistance

Supports 0 – 100 millivolt inputs on anychannel

Additional Product Information:

On CTI’s Website you will find links to the 2500 Series Standard Environmental Specifications

and the UL Agency Certificates of Compliance.

CTI 2551-A 8-Channel Isolated Thermocouple Input Module

Description

The 2551-A is a high-speed 8-channel isolated thermocouple input module de- signed

to be compatible with the CTI 2500 Series® and Simatic® 505 I/O base in local,

remote I/O, and Profibus configurations. The 2551-A translates thermocouple and

millivolt input signals into a scaled temperature value.

Features

 Simatic® 505 I/O base format

 1500 V channel-to-channel isolation

 1500 V channel-to-PLC backplane isolation

 Fast 2 mSec update time per channel

 On-board cold junction compensation for each thermocouple input

 Microprocessor self-diagnostics

Additional Product Information:

On CTI’s Website you will find links to the 2500 Series Standard Environmental Specifications

and the UL Agency Certificates of Compliance.

CTI 2551-A Specifications

Specifications

Input Channels: 8 isolated input channels, individually configurable for thermocouple or millivolt input

Thermocouple Types: J or K, jumper selectable for each channel

Millivolt Input: 0 – 55 mV

Digital Filtering Time Constant: 0.3 Sec

Output Units: Degrees C or F,

(jumper selectable for all outputs)

Repeatability: 0.05%

Accuracy: Type J: ±1° from 0° to 760°C

Type K: ±1° from 0° to 1372°C Millivolt: .06 Millivolt

Resolution: 0.3°C, 0.6°F thermocouple input

.020 millivolt input

Common Mode Rejection:

>110db @ 60Hz (digital filtering disabled)

Normal Mode Rejection:

>45db @ 60Hz (digital filtering enabled)

Input ESD Protection: 20.000 V

Overrange Protection: 20 VAC for 1 minute (all input terminals)

Isolation: 1500 VDC channel-to-channel 1500 VDC channel-to-PLC

Connector: Fixed

Wire Gauge: 18-24 AWG

Backplane Power: 2.4 Watts

Module Size: Single-wide

Shipping Weight: 1.5 lb (0.68 Kg)

CTI 2534 8-Point Form-C Relay Output Module

Description

The 2534 8-Point Form C Relay Output Module provides eight isolated Form C relay outputs

for the CTI 2500 Series® or the SIMATIC® 505 I/O base. This module plugs directly into

the CTI 2500 Series® I/O base and responds to CTI 2500 Series® instructions.

The 2534 is designed for high current applications such as switching motor starters.

It is also designed for 125 VDC (nominal) low level current applications and is especially

suited for applications in power utility substations.

Features

• CTI 2500 Series® base format

• 8 Form C relay outputs

• Isolated 1500 VDC channel-to-backplane

• Wide 15-240 VAC, 15-150 VDC output range

• 4.0 Amps per output

• Individually fused outputs

• Single-wide module

Specifications

Outputs per module: 8

Isolation: 1500 VDC channel-to-backplane

1500 VDC channel-to-channel

Output voltage: 15 – 240 VAC

15 – 150 VDC

Inrush current: 64 Amps for 2 mSec Indicators: 8 individual LEDs Maximum output current:

15VAC – 240VAC: 4A

15VDC – 30VDC: 4A

150VDC: Resistive: 1mA – 500mA Inductive: 1mA – 250mA

Switching rate: 5 ops/sec (no load)

Type of contact: Form C

Type of outputs: Individually fused

Contact life: @ full rated current, 4A = 300.000 cycles @ 2A = 1.000.000 cycles

Backplane Power: 1.0 Watt

User Power Supply: 24VDC +10%

160 mA (all outputs ON)

Fuses: 8. 5 amp, 250V, field replaceable Type Littelfuse #215-005 or Schurter #0001.2511

Connector: 2500-40F sold separately

Wire Gauge: 14 – 22 AWG

Module Size: Single-wide

Shipping Weight: 1.8 lb. (0.82 Kg)

Additional Product Information:

On CTI’s Website you will find links to the 2500 Series Std Environmental Specifications and

the UL Agency Certificates of Compliance .

CTI 2530 8-Point Form-C Relay Output Module

Description

The 2530 8-Point Relay Contact Module provides eight isolated “Form C” relay outputs

for the CTI 2500 Series® or Simatic® 505 I/O base. The 2530 is designed for high

current applications such as switching motor starters.

The 2530 is also designed for 125 VDC (nominal) low level current applications. 

This module is especially suited for applications in power utility stations.

Features

• 8 individually isolated “Form C” relay outputs

• Up to 4 amps per output

• 1500V channel-to-PLC backplane isolation

• Switches 125 VDC (ideal for power utility substation applications)

• Single-wide module

• CTI 2500 Series® base format

CTI 2598-8 Channel Configuration Explanation

Channel Configuration Explanation

The 2598-8 was designed using a PCB that could also perform as a 16 or 32pt module.

Hence, the PCB printing for channels do not line up with actual 2598-8 channels.

See chart below for the proper correlation of channels.

For example, if the module reported channel 4 was blown, then the user would replace

the fuse marked ‘CH 10’ on the PCB.

Grouping Configuration

The 2598-8 is shipped to allow two channels to be grouped and share a common field

user power, thereby allowing a different user power supply voltage to be used by each

grouping. Jumpers J2. J4. J6. and J8 come set in the “8 common” selection from the

factory and should not be altered for proper module operaton. This setting allows for 

2 points per common operation.

For example, Channels 1-2 will share a common user power and Channels 3-4 will share

another common user power. In this example each group of two channels is isolated

from the other group of two channels. Be-cause each group of two is isolated,

the user may also change the supply voltage for each group.

So, in this example, Chan- nels 1-2 could be 240VAC outputs and Channels 3-4 could

be 120VAC outputs.

CTI 2598-8 Specifications

Specifications

Outputs per Module: 8

Isolation:

2100 VDC channel-to-backplane

3000 VDC group-to-group

Output Voltage: 11 VAC to 240 VAC

Maximum Output Current:

2.0 Amps max.,

4A per group

16A per module

For Class 1 Div 2 locations:

2A per point @50°C

1.5A per point @ 60°C

Maximum Surge Current: 3 Amps for 15 Sec

“ON” State Voltage Drop: 1.0V @ 1.0 Amp

“OFF” State Leakage Current: 1mA

Turn  On Time: 1 AC cycle

Turn  Off Time: 1 AC cycle

Fuses:

16. 2.5 amp, 250V, Type: Littlefuse #21602.5.

Bussman GDA-2.5 (Field replaceable)

Connector: Removable Part# 2500-40F

Note: The connector is ordered separately.

Wire Gauge: 14 – 22 AWG

Backplane Power: 1.25  Watts max.

Module Size:  Single-wide

Shipping Weight: 1.5 lb. (0.68 Kg)

CTI 2598 8/16-Point AC Discrete Output Module

Description

The 2598 8/16-Point AC Discrete Output Module

provides eight outputs  isolated in groups of 2 from

CTI 2500 Series® or Simatic® 505 I/O bases. The

module utilizes solid-state output circuits  to switch on

or off external devices such as pilot lamps, motor

starters, or solenoids. The 2598-8 is designed to

switch externally supplied 11 to 240 VAC. The internal

logic signals are isolated from the external outputs to

2100 VDC.

Features

• 8 AC output points

• Replaces Siemens® 505-4608. and -4808.

• 3000 VDC group-to-group isolation

• 2100 VDC channel-to-backplane isolation

• Isolation in groups of two

• Wide 11-240 VAC output range

• 2.0 Amps per output

• 16 Amps total module output

• Individually fused outputs

• Sourcing outputs

• Single-wide module