Welcome to the official website of CNIACS Automation Technology Co., Ltd!

CTI 2500P-JACP Features

Features

• Adds IEC-61131 languages, functions, and memory organization features to existing

CTI 2500 Series® and SIMATIC® 505 controllers

• Advanced diagnostics and module status provided by the embedded web server

• Embedded client/server protocols perform data transfer based on configuration tables

without the need for any additional logic in the PLC or 2500P-JACP application program

• High-speed data transfer and RTC time synchronization with CTI controllers

• Supports user-created graphics pages containing variable data which can be accessed

via web browser

COMMUNICATIONS PROTOCOLS

• CAMP Client (TCP, UDP, Multicast)

• CAMP Server

• Block Transfer Driver for communication with Simatic/TI 545 and 555 processors

• Open Modbus (Client, Server)

• Ethernet/IP Scanner, Adapter, Tag Client, Explicit Message Client, Explicit Message Server,

Flex I/O Scanner

• Profinet Controller and Device (Future)

• Serial Modbus RTU (Master, Slave)

• General ASCII Send/Receive

• TCP/UDP Management Functions

• Network Data Exchange

• MQTT

• OPC-UA Server

CTI 2500P-JACP Janus Application Coprocessor

The 2500P-JACP Janus Application Coprocessor is a general-purpose auxiliary

controller that enhances the capabilities of all CTI 2500 Series® and SIMATIC®

505 PLC systems. This Advanced Function Module is based on Janus technology

and includes high-speed processing and multi-protocol communications support

to provide existing systems with a significant increase in performance, features,

and functionality.

Because of its broad communications capabilities and ability to store large amounts

of data on-board, the 2500P-JACP is ideal for Edge Computing applications, bringing

computation and data storage closer to the location where it is needed, to improve

response times and save bandwidth.

The 2500P-JACP runs as a PLC coprocessor performing complex logic/math functions,

data logging, and communications with external devices. Although the 2500P-JACP

can operate as a standalone controller, the control application generally requires data

transfer between a host PLC and the module. Two different data transfer options are

provided:

Block Transfer Driver: The 2500P-JACP enables the user to configure the Block Transfer

Driver which optimizes the exchange of up to 2048 data points with a Siemens, TI, or

CTI PLC using the special function I/O backplane protocol. The application can select to

exchange V, X/Y, WX/WY, or Control Relays for continuous Read or Read/Write.

Note this feature allows the 2500P-JACP to be used with existing Simatic/TI 545 and

555 PLCs.

Data Cache: Proprietary link offering enhanced data throughput to CTI 2500 Series®

controllers via a dedicated Ethernet connection. Supports up to 6144 variables mapped

to any PLC memory type (including Loop/Alarm variables). 

The 2500P-JACP includes two external 10/100/1000Mb Ethernet ports with automatic

detection of network speed, duplex mode, and cable wiring. An aliasing and isolation

feature allows the two network ports to exist on two separate networks, a useful feature

for isolating networks of drives or other I/O devices from the main plant communications

network.

Need help selecting an Ethernet solution?  Click on the link below to get help from an

Applications Engineer.

CTI 2541 Features

Features

• Automatically transfers control to standby PLC upon loss of I/O scan

or “heartbeat” pulse from the active PLC

• Switches both remote I/O and serially attached operator interface devices

• Enables PLC logic to monitor status and control switchover, if desired.

• Allows optional manual switchover capability

• Uses high-reliability relays to directly connect the active PLC and remote

I/O without intervening

electronics.

• Defaults to a user-defined switched position on power loss or hardware

failure

• Provides LEDs to visually indicate status of control

• Transfers up to 4096 words of critical data between active and standby

PLCs every scan

CTI 2541 Redundant Processor Manager Module

The 2541 Redundant Processor Manager (RPM) provides an automatic

backup solution for 2500 Series® PLCs. If the active PLC fails, the RPM

will automatically switch the remote I/O to the standby PLC.

Transfer to the standby PLC is bumpless. All remote I/O updates are

mirrored to the standby PLC. In addition, up to 4096 words of user-

defined critical data can be transferred from the active PLC to the 

standby PLC every scan.

Other non-critical data can be transferred over several scans.

The RPM can also switch up to two serially attached operator interface

devices.

IMPORTANT NOTE: Due to extensive component obsolescence issues

and insufficient demand to justify a re-engineering effort, this product

has been matured.  For users needing PLC redundancy in the future,

we have a solution planned based on our new Janus Programmable

Automation Controller which uses two Janus PLCs and a Modbus relay

that switches Remote I/O and Profibus networks from the primary PLC

to the backup in case of a Processor failure.

CTI 2577 Profibus DP Slave Adapter

The 2577 allows a Profibus Master to read any PLC V, WX, X, and C

memory location and write any V, WY, and C memory location over

Profibus.

Features

• No changes required to existing PLC configuration and I/O

• Allows transfer of up to 110 words of data in and 110 words of data

out to Profibus Master

• Maintains statistics and diagnostic information for the Profibus network

• Auto-senses Profibus baud rate

• Integrates CTI 2500 Series® and Simatic® 505 systems into S7 and

PCS7 designs

Files & Documents

• VUser Manual

• Quick Start Guide

• Product Bulletin

• GSD File

Application Notes

• Configuring the 2577 Profibus-DP Slave Adapter using Workshop

Technical Advisories

• Using 2577 Profibus Slave Adapter with 2500 Series® Processors

(March 6.2008)

• Configuring the CTI 2577 Profibus Adapter with some versions of COM Profibus and Step 7

CTI 2573-MOD Serial Interface Adapter with MODBUS

The 2573-MOD provides support for communicating with serial and Modbus

plant floor devices such as modems, bar code readers, scales, displays,

printers, and other PLCs.

Features

• Provides 4 serial ports, each providing RS-422. RS-485 and RS-232 electrical

interfaces. All ports operate concurrently and independently.

• Enables the PLC to act as a master or slave for devices which use Modbus

RTU or ASCII protocols

• Task Code Master support allows the local PLC to access memory in other

2500 Series® or Simatic® 505 PLCs

Application Notes

• 2573-TCM2 to Mettler/Toledo PG5001 Scale

• Upgrading from a Siemens® Simatic® 505-5184 Module

• 2573-TCM2 to Ohaus IP Series High Capacity Precision Toploaders

• 2573-TCM2 to Mettler/Toledo SM3000 Scale

• 2573-MOD to 3300 ACM Digital Power Meter

• 2573-TCM2 to MTS Digital Access Tank Gauge

• 2573-MOD to S7-200 PLC

• Distributed PID Temperature Control From a PLC using Eurotherm Series

2000 PID Temperature Controllers with Modbus RTU Communications

• Using the CTI 2573-MOD Serial Interface Adapter with Microwave Data

Systems Master/Remote Radios

CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection

The 2572-AF Ethernet TCP/IP Adapter with Optical Fiber

Connection is the next generation 2572 network interface

module for 2500 Series® controllers.

The 2572-A provides connectivity to Ethernet networks

using IEEE 802.3. Ethernet II and Transmission Control/

Internet Protocol standards, at 10M or 100M speeds.

IMPORTANT NOTE: 2572-AF HAS BEEN MATURED. 

IT IS REPLACED BY 2572-B or 2500P-ECC1.

WHICH SHOULD BE USED ON ALL NEW DESIGNS.

Features

• Compatible with Siemens® 505-CP2572 and CTI 2572

• Direct Fiber MTRJ connection

• TCP/IP support includes UDP and TCP

• Remote programming over Ethernet

• MMI/HMI connectivity

• DDE and OPC support available

• DHCP configuration option

• Built-in web server for diagnostics

CTI 2572-A Fast Ethernet TCP/IP Adapter

The 2572-A Ethernet TCP/IP Adapter is the next generation

2572 network interface module for 2500 Series® or Simatic®

505 controllers. The 2572-A provides connectivity to Ethernet

networks using IEEE 802.3. Ethernet II and Transmission

Control/Internet Protocol standards, at 10M or 100M speeds.

IMPORTANT NOTE: 2572-A HAS BEEN MATURED.

IT IS REPLACED BY 2572-B or 2500P-ECC1.

WHICH SHOULD BE USED ON ALL NEW DESIGNS.

Features

• Compatible with Siemens® 505-CP2572 and CTI 2572

• Auto-sensing for 10/100Mbps networks

• TCP/IP support includes UDP and TCP

• Supports Modbus-TCP and Ethernet/IP protocols

• Remote programming over Ethernet

• MMI/HMI connectivity

• DDE and OPC support available

• DHCP configuration option

• Built-in web server for diagnostics

CTI 2572-A Application Notes

Application Notes

• Guide for Converting Ethernet Applications from 2572 /

2572-A / 2572-B to 2500P-ECC1

• Setting the IP address using the PLC on 2572-A and

2572-B (Tech Tip)

• 2572 Installation and Setup Instructions

• Assigning an IP Address to the 2572-A without Connecting

to the Module

• Communication to Simatic S7 Using Open Modbus

• Creating a Client/Server Memory Transfer between Two

2572-X Modules

• Getting Started with Networking and the 2572

• Reading Values into Excel Spreadsheets Using the 2572

• Replacing a Peerlink Network with Ethernet and 2572-A

• Using CTIDIAG with the 2572

• Using the 2572 UDP “Send To” Feature to Exchange Memory

with Multiple PLCs

• Using the 2572 with Wonderware 7.0

• IP Addressing and the 2572

• Starting the 2572 Network Server from PLC Logic

CTI 2572-B Fast Ethernet TCP/IP Adapter

The 2572-B Fast Ethernet TCP/IP Adapter is the next generation Ethernet

network interface module for 2500 Series® or Simatic® 505 controllers.

The 2572-B provides connectivity to Ethernet networks using IEEE 802.3.

Ethernet II and Transmission Control/Internet Protocol standards, at 10M

or 100M speeds.

For help selecting the right Ethernet solution for your needs, see our

Tech Tip:

Ethernet Communications: What is the Best Solution for Your Needs?

or click on the link below to get help from an Applications Engineer.

Get Help With Ethernet

Features

• Direct replacement for 2572-A

• Compatible with CTI 2572-A, CTI 2572. and Siemens® 505-CP2572

• New IP address display on front panel

• No serial connection required to set IP address

• DHCP address switches eliminated (contact CTI if your application

uses DHCP)

• Auto-sensing for 10/100Mbps networks

• TCP/IP support includes UDP and TCP

• Supports Modbus-TCP and Ethernet/IP protocols

• Remote programming over Ethernet

• MMI/HMI connectivity

• DDE and OPC support available

• Built-in web server for diagnostics