Welcome to the official website of CNIACS Automation Technology Co., Ltd!

CTI 2585 16-point TTL Input Module

Description

The 2585 16-Point TTL Input Module accepts sixteen

TTL driven inputs to the CTI 2500 SeriesTM or

Simatic® 505 Series I/O base. The inputs are

isolated channel-to-channel.

The 2585 has an input voltage range from 2.6 to 28

VDC; therefore, the inputs may be driven by CMOS

and open collector transistor devices.

Features

• CTI 2500 Series and Simatic 505 base format

• 500 V channel-to-channel isolation

• 1500 V channel-to-PLC backplane isolation

Specifications

Inputs per module: 16

Isolation:

500 VDC channel-to-channel

1500 VDC channel-to-backplane

Input Voltage:

2.6 to 28 VDC

TTL OFF <0.8 VDC TTL ON > 2.6 VDC

1500 VDC channel-to-backplane

Input Current:

20 mA max. per circuit (0.5 mA @ 2.6 VDC)

Isolation:1500 VDC channel-to-backplane

Turn ON Time: Approx. 1 mSec nominal

Turn OFF Time: Approx. 2 mSec nominal PLC

Reporting:  X or WX (jumper selectable)

Wire gauge: 14-22 AWG removable connectors

Backplane power: 1.4 Watts (all outputs active)

Module size: Single-wide

Blown fuse indication: Front panel LED

Shipping Weight: 1.5 lb. (0.68 Kg)

Additional Product Information:

On CTI’s Website you find will links to the 2500

Series  Std Environmental Specifications and the UL

Agency Certificates of Compliance .

CTI 2576 DeviceNet™ Scanner Module

Product Summary

The 2576 DeviceNet Scanner is a SIMATIC® 505

module that enables the PLC to access devices on a

DeviceNet network. The 2576 module writes data

supplied by the PLC to DeviceNet devices and obtains

data from these devices and presents it to the PLC as

standard I/O.

Since DeviceNet data appears to the PLC as standard

data types, no special PLC programming techniques are

required to access the DeviceNet devices. Using a CTI

supplied configuration program, the user can specify

how device data will appear to the PLC. Inputs from

the device may be mapped to X, WX, or V memory

locations. Outputs to the device may be mapped to Y,

WY, or V memory locations.

To maximize performance and provide maximum

flexibility, the 2576 logs into the PLC as two I/O slots –

a high-density I/O slot and a special function slot. The

high-density I/O interface provides 32 discrete-in (X),

32 discrete-out (Y), 32 word-in (WX) and 32 word-out

(WY) data points.  The Special Function interface can

transfer up to 480 words per PLC scan. It can also be

used by the PLC to send special commands to the module.

The module DeviceNet port can operate at baud rates

up to 500Kb.  A serial port provides a means to

download configuration record and software updates.

The front panel includes a complete set of LEDs that

display module and DeviceNet status.  The module also

includes a DeviceNet power tap, which allows the user

to connect a power supply to the network.

CTI 2576 allows a 2500 Series® PLC to read I/O devices on a DeviceNet™ network

The 2576 allows a 2500 Series® PLC to read I/O devices on a DeviceNet™ network.

The module provides one DeviceNet™ channel which can attach up to 63 network

devices. Multiple modules can coexist in the same I/O chassis.

Features

• DeviceNet™ points appear as a standard PLC I/O

• RS-232 serial port enables configuration of module and network devices

• Front panel LEDs allow monitoring of module and network devices

• Built-in power tap can be used to power DeviceNet™ network

Files & Documents

• Product Maturity Announcement

• Product Bulletin

Manuals

• User Manual V1.2

Application Notes

• Getting Started with the 2576 DeviceNet Scanner and Cutler-Hammer Motor Starters

CTI 2500-R4 Four-Slot Base with High-Speed Channel

Description

The 2500-R4 / 2500-R8 / 2500-R16 bases

provide four, eight, or sixteen slots for I/O

modules in the SIMATIC® 505 or CTI 2500

Series platform. The bases provide space for

a power supply, a CPU or RBC, and slots for

up to four, eight, or sixteen I/O modules. The

base may be mounted from the front or rear.

Features

• Replaces Siemens® 505-6504. 505-6508.

or 505-6516

• Four, eight, or sixteen I/O slots

• Up to 128. 256. or 512 I/O points (4. 8. or

16 slot respectively)

• Mounts from the front or rear

Specifications

Mounting:

Front or rear mounting

Rack Size:

2500-R4: 8.02”W x 8.0”D x 10.47”H

204mm W x 203mm D x 266mm H

2500-R8: 11.22”W x 8.0”D x 10.47”H

285mm W x 203mm D x 266mm H

2500-R16: 17.62”W x 8.0”D x 10.47”H

448mm W x 203mm D x 266mm H

Operating Temperature:

0o to 60oC (32o to 140oF)

Storage Temperature:-40o to 85oC (-40o to 185oF)

Relative Humidity:

5% to 95% (non-condensing)

Agency Approvals Pending:

UL/ULC, Class1-Div.2-Haz.Loc., CE

Shipping Weight:

2500-R4: 5.0 lb.(2.27 Kg)

2500-R8: 8.0 lb.(3.63 Kg)

2500-R16: 14.0 lb.(6.35 Kg)

Power Supply, CPU/RBC, and I/O Location in Base

The power supply must always be installed in the left most slot of the

base. To the right of the power supply is a slot for a CPU or RBC. The

remaining 4. 8 (shown below) or 16 slots are for I/O or communication

modules.

CTI 2500P-J750 Files & Documents

Files & Documents

• Product Release Announcement

• 2500P-J750- Product Bulletin (French)

• 2500P-J750 Product Bulletin

Manuals

• Janus Processor Quick Start Guide

• Janus Processor IOG

• 2500 Series® Remote I/O System Guide

Application Notes

• Using Online Change in Janus Processors

• PID Basics in Janus Workbench

• Janus Communication using DNP3 (Tech Tip)

• Janus Communication using DNP3 (Sample Files)

• Setting Up Secure OPC-UA Communications

Application Highlights

• Using Janus to Implement an Edge Computing Application to Collect and

Analyze Data to Optimize Production Costs

CTI 2500 Series 2500P-J750 Features

Features

• Up to 10x execution speed compared to current 2500 Series CPUs

• Programming is done using CTI’s Janus Workbench Software development

package which includes all IEC-61131 languages (SFC, FBD, LD, ST and IL)

• Built-in Remote I/O and Profibus interfaces with support for all existing 2500

Series discrete and analog modules

• External SD card for user backup and file transfer while in RUN mode

• Four Ethernet ports with internal switch that supports simultaneous connection

to four different Ethernet networks

• Embedded HMI function to easily create and view graphics screens for local

operator interface directly from the PLC

• Extensive built-in communications capabilities:

• Optimized peer-to-peer communications with all CTI CPUs and the ACP1

• CAMP server for HMI/SCADA access

• CAMP client for communicating with CTI 2572/2572-x and Cxxx processors

• Open Modbus client and server

• EtherNet/IP Scanner/Adapter/Tag Client/Server

• MQTT client for direct access to the IIoT

• OPC-UA server (firmware 1.24 and above)

• Profinet controller and device (future)

CTI 2500P-J750 Janus PAC with 3MB Project Memory

Our new family of Janus PACs will bring completely new capabilities to

the CTI 2500 Series® System. Designed to work seamlessly with

existing Siemens/TI 505® and CTI 2500 Series® Systems as well as to

look to the future with state-of-the-art programming, protocols, and

capabilities, including direct access to the Industrial Internet of Things

(IIoT) using MQTT, these PACs are very fast, agile and optimized for

quick, easy and cost-effective communications. Our new Janus PAC

includes integrated drivers to a wide variety of protocols, allowing

communications with best-in-class I/O, drives, and HMI/SCADA no

matter the manufacturer. It also utilizes CTI’s budget- and user-friendly

new Janus Workbench Software programming package that includes all

IEC programming languages. Initially available in our Classic size, this

family now includes fully featured Compact versions as well.

CTI 2500C-J750 IMPORTANT NOTE ON MAXIMUM  ETHERNET CONNECTION LIMIT

IMPORTANT NOTE ON MAXIMUM  ETHERNET CONNECTION LIMIT

The 2500C-J750 permits a maximum of 64 Ethernet connections. 

This is the TOTAL of all Client protocol connections that are configured,

plus whatever external devices connect to Server protocols.

For example, suppose an application has:

5 Modbus clients configured

4 Modbus devices which connect to the Modbus Server

16 Ethernet/IP scanner devices configured

2 devices which connect to the Ethernet/IP Tag Server

8 CAMP Client connections configured

4 devices which connect to CAMP Server

4 devices which connect to OPC-UA Server

This application has used (5+4+16+2+8+4+4) or 43 out of

the possible 64 connections.

CTI 2500C-J750 KEY FEATURES

KEY FEATURES

• Programmed using Janus Workbench Software

(JSoft), which allows use of all IEC-61131-3

languages: LD (RLL), FBD, ST, SFC and IL

• Up to 10x execution speed  compared to

current 2500 Series® CPUs

• Built-in Remote I/O and Profibus interfaces

with support for all existing 2500 Series®

discrete and analog modules, Classic and

Compact.  NOTE: Special Function modules are

not currently supported, However, due to the

enhanced communication capabilities of the

Janus controller, Ethernet-based special function

modules are no longer necessary.

• Built-in web server for diagnostics and statistics

simplifies troubleshooting and support

• Built-in web-based visualization of graphics

pages designed in Janus Workbench

• Entire operating system, firmware, and user

program is contained on a standard SD card,

which makes replacement of the PLC easy,

should you ever have a failure

• Four Ethernet ports with internal switch that

supports simultaneous connection to 4

different Ethernet networks

• Support of multiple communication protocols for

connecting to major HMI and SCADA systems

• Extensive built-in communications capabilities:

 Optimized peer-to-peer communications with

other JANUS Series PACs and 2500P-ACP1 /

2500P-JACP/ 2500P-ECC1 coprocessors

 CAMP Client for communicating with all CTI

Ethernet products (2572. 505-CP2572. 2572-A,

2572-B, 2500P-ECC1. 2500 Series® CPUs)

 CAMP Server for HMI/SCADA access

 Open Modbus Client and Server

 Ethernet/IP Scanner

 Ethernet/IP Adapter

 Ethernet/IP Tag Client

 Ethernet/IP Tag Server

 MQTT client for direct access to the IIoT

 OPC-UA server (firmware 1.24 and above)

 Profinet controller and device (future)

CTI 2500C-J750“Janus”Compact Programmable Automation Controller

DESCRIPTION

The new Compact “Janus” Processor brings

completely new capabilities to the CTI 2500 Series®

System.  Designed to work seamlessly with existing

2500 Series® (Classic and Compact) and Simatic®

TI505 Systems as well as look to the future with

state-of-the-art programming, protocols and

capabilities, including support for Industry 4.0

through direct access to the Industrial Internet of

Things (IIOT) using MQTT.

This Programmable Automation Controller (PAC) is

fast, agile and optimized for quick, easy, and cost

effective communications.  It features integrated

drivers to an industry-leading number of protocols,

allowing communications with best-in-class I/O

devices, drives, and HMI/SCADA  no matter the

manufacturer. Programmed with CTI’s user-friendly

and budget-friendly new JANUS Workbench

Software, which supports all IEC-61131-3 programming

languages.

Search for products

Back to Top
Product has been added to your cart