Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Prosoft A-DNTR/B Features

Features

• DeviceNet Scanner or DeviceNet Device

• Support for multiple DeviceNet network baud rates (125K, 250K, 500K)

• Support for DeviceNet pass-through or explicit messaging

• PCCC client mode to connect to Ethernet-only PanelViews to an existing DeviceNet network

• EtherNet/IP Target or Originator with support for Class 1 connections

• Supports Modbus TCP/IP (Ethernet) and Modbus RTU (Serial) Client/Server

• Direct-to-Tag Technology

• Dual Ethernet ports with support for DLR (Device Level Ring)

• Support for NTP (Network Time Protocol) for external clock synchronization

• Advanced Diagnostics, including packet capture

Configuration

The Slate Configuration Utility software is used for configuration and troubleshooting of the module. The stand-alone

configuration utility allows users to define the setup and configuration of the DeviceNet Router module, connections

with controllers and devices.

Prosoft A-J1939R/B J1939 Router/B

The A-J1939R/B provides intelligent data routing between either

EtherNet/IP™, Modbus TCP/IP®, or Modbus® RTU to a J1939 network.

This allows the user to integrate J1939 devices into a Rockwell

Automation Logix platform (e.g., ControlLogix® or CompactLogix™) or

any Modbus Client or Server device.

The A-J1939R/B provides auto extraction and scaling of SPNs

(Suspect Parameter Number) that can be mapped to Logix UDTs Tags.

The A-J1939R/B allows the user to select standard specification

defined PGNs (e.g., PGN 61444-Electronic Engine Controller 1) from a

list in the Slate software. The user can then export a Logix UDT from

the Slate software which maps the PGN selected.

Configuration

The Slate Configuration Utility software is used for configuration and trouble

shooting of the router. The stand-alone configuration utility allows users to

define the setup and configuration of the J1939 router and its connections with

controllers and devices.

Prosoft A-J1939R/B J1939 Router/B Features

Features

• EtherNet/IP Target or Originator with support for Class 1 connections

• Supports Modbus TCP/IP (Ethernet) and Modbus RTU (Serial) Client/Server

• Direct-to-Tag Technology

• Dual Ethernet ports with support for DLR (Device Level Ring)

• Support for NTP (Network Time Protocol) for external clock synchronization

• Advanced Diagnostics, including packet capture

• Support for pass-through or explicit messaging

Configuration

The Slate Configuration Utility software is used for configuration and trouble

shooting of the router. The stand-alone configuration utility allows users to

define the setup and configuration of the J1939 router and its connections with

controllers and devices.

Prosoft PS-QS-1×11-F LonWorks QuickServer Gateways

The QuickServer line of communication gateways are designed to link building

automation networks utilizing LonWorks with industrial control networks

communicating on BACnet/IP, EtherNet/IP, Modbus TCP/IP, and Modbus RTU.

The QuickServer gateways are available with limits of up to 250 or 500 points of

application data.

Specifications

Field Connections

▪ Ethernet 10/100 RJ45

▪ Serial RS-485 terminal (up to 115K baud)

▪ FTT-10 LonWorks port

Environment

▪ Operating temperature: -40°F to 167°F (-40°C to 75°C)

▪ Relative humidity: 5% to 90% RH, with no condensation

Power Requirements

▪ 9 to 30 Vdc or Vac or 5 Vdc

▪ Current draw 250mA @ 12V

Other

▪ Configuration/Diagnostic utilities

▪ Capacity: 250 or 500 Points

▪ Table, Wall or DIN rail mount

Physical Dimensions (W x D x H)

▪ 4.5 x 3.2 x 1.6 in. (11.5 x 8.3 x 4.1 cm)

▪ 0.4 lbs (0.2 Kg)

Approvals

▪ TUV approved to UL 916 standard

▪ CE Mark

▪ BTL Mark (PS-QS-1010)

▪ RoHS Compliant

▪ FCC Part 15 Compliant

Prosoft PS-QS-1×11-F Ordering Information

Ordering Information

To order this product, please use the following:

PS-QS-1011-F

PS-QS-1211-F

250 Points

500 Points

How to Contact Us: Sales and Support

Sales and Technical Support for this product are

provided by ProSoft Technology. Contact our

worldwide Sales or Technical Support teams

directly by phone or email:

Asia Pacific

+603.7724.2080. asiapc@prosoft-technology.com

Europe – Middle East – Africa

+33 (0) 5.34.36.87.20. Europe@prosoft-technology.com

North America

+1.661.716.5100. support@prosoft-technology.com

Latin America (Sales only)

+1.281.298.9109. latinam@prosoft-technology.com

LonWorks® is a trademark of Echelon Corporation

Metasys® is a trademark of Johnson Controls

BACnet® is a trademark of ASHRAE

Prosoft AN-X3-GENI Features

Features

 Configures through a web browser (No separate configuration software

required)

 Customizable configuration files provide additional flexibility

 Supports offline configuration through a .CSV file

 Monitor mode enables testing and verification of PAC logic before controlling

physical I/O, reducing the risk of production loss

due to programming errors

 View diagnostics with a web browser enabling remote monitoring and

troubleshooting

 Micro SD card backs up configuration files – Can be transferred to the unit to

minimize downtime in the event of a disaster

GE Genius™ Bus Features

 Supports sending and receiving Global Data on the Genius Network

 Supports baud rates: 38.4. 76.8. and 153.6 Kbps (Standard and Extended)

 Configurable bus address

 Auto-Configuration feature discovers and maps up to 31 Genius Blocks of I/O

(Online) EtherNet/IP™ Bus Features

 Supports up to 16 I/O connections for real time control

 Supports multicast and unicast connections

 Each connection can have a unique RPI from 2 to 750 mSec allowing the

prioritization of I/O data

 Auto-Configuration feature maps the discovered GE I/O points into tags in the

PAC controller

 Diagnostic data can be mapped into PAC memory making this data available to

HMIs

Prosoft AN-X3-GENI EtherNet/IP™ to GE Genius™ I/O Gateway

The EtherNet/IP™ to GE Genius™ gateway allows an Allen-Bradley®

Programmable Automation Controller (PAC) to control GE Genius I/O

devices. This gateway allows a phased migration approach to be used

when upgrading or replacing GE Genius based 90-30™ and 90-70™

controllers. The gateway provides automatic creation of the Genius scan

list and generates the associated RSLogix™ 5000 tags reducing

engineering effort. Monitor mode allows verification of your conversion

logic using live I/O data without impacting the running legacy system.

Once the new PAC is commissioned the legacy I/O can be upgraded one

module or one rack at a time as scheduled downtime is available. This

gateway minimizes the risk of excessive downtime when upgrading

legacy control systems.

Prosoft A-FFL/B FOUNDATION™ Fieldbus H1 Master Features

Features

 Operates as a FOUNDATION™ Fieldbus H1 Master.

 Supports up to 32 FOUNDATION™ Fieldbus H1 field devices.

 Module has various configurable primary interfaces:

o EtherNet/IP Target

o Modbus TCP Server

o Modbus TCP Client

o EtherNet/IP Originator (Class 1- connections 10 and Explicit Messaging with up to 10 EtherNet/IP devices).

 Provides a built-in Isolated Power Conditioner that can supply up to 420mA.

 Allows the use of external Power Conditioners for Intrinsically Safe (IS) applications.

 Provides a built-in software enabled Fieldbus terminator.

 Dual Ethernet ports which support Device-Level-Ring (DLR).

 Built-in H1 and Modbus packet capture.

 Supports detailed H1 live list, H1 Alert (Alarm) extraction, and H1 Master Redundancy

 Device Specific UDT, tag and logic generation for import into a Studio5000 project.

 Network Time Protocol (NTP) supported for external time synchronization.

 Device Type Manager (DTM) supported.

 Online change configuration supported.

 Optional Advanced H1 scheduling.

Prosoft A-FFL/B FOUNDATION™ Fieldbus H1 Master for EtherNet/IP™ and Modbus® TCP

The FF Link module simplifies the implementation of FOUNDATION™

Fieldbus H1 by combining an EtherNet/IP™ and Modbus® TCP Linking

device with an internal isolated power conditioner and bus terminator.

The FF Link supports module redundancy when in EtherNet/IP target

mode, allowing two FF Link masters to be connected to the same H1

segment in a one-active-one-standby strategy.

Configuration is achieved using Aparian’s free-downloadable Slate

configuration environment. Slate generates H1 device specific UDTs and

mapping code which can be imported into Studio 5000. allowing even

complex systems to be configured in minutes.

Prosoft ELX3 Features

Features

• Redundant Power connections (12 ~ 24 V DC)

• Multiple Ethernet ports (4) supporting 10/100/1000 Mbit/s

• Industrial-rated hardware supporting user defined custom Docker container

applications

• ProSoft supported ELX-EIP-MBTCP protocol gateway container for EtherNet/IP

and Modbus TCP/IP protocol gateway conversion

• Class 1 Division 2 hardware with -40°C to +70 °C operating temperature range

for Edge applications

Search for products

Back to Top
Product has been added to your cart