Prosoft PLX51-DL-232 Data Logger

What if you could have your control devices’ data stored for

predictive maintenance or process improvements?

The PLX51-DL-232 Data Logger is ideal for remote sites with

limited communications that need to log data. OEMs can log their

machine’s data to identify operational problems or efficiency

improvements. The PLX51-DL-232 can read and store data from

EtherNet/IP PLCs, DF1 Serial PLCs and devices, or Modbus®

PLCs and devices. The PLX51-DL-232 has the capacity to store

over 16 million records in its solid-state non-volatile memory.

Each stored record includes a Date Time stamp, Tag Name,

Data Type, and Value.

Features

 Data can be manually downloaded to a CSV file using the PLX50

Configuration Utility

 A built-in webserver provides detailed diagnostics of system

configuration and operation

 Two logging modes: Data stored until memory is full or oldest data

overwritten when memory full, first in, last out

Prosoft PLX51-HART-4I 4 Channel HART Input Module

The PLX51-HART-4I allows users to easily connect their existing HART

compatible field devices to EtherNet/IP™, Modbus® TCP/IP, and DNP3

Ethernet networks. The module can be used to connect HART Input

devices such as process instruments into an Ethernet network.

The PLX51-HART-4I supports up to 4 channels of HART communication,

as well as Analog 4-20 mA signals for real-time process variables to/from

the HART-compatible device.

♦ DNP3 converts a HART field device into a DNP3 Outstation (slave) supporting Secure Authentication

♦ Support for point-to-multipoint network, maximum of 7 devices with EtherNet/IP protocol

♦ DTM (Device Type Manager) / HART Pass-through is available for simplifying device configuration and

management using an FDT frame

♦ Built-in webserver provides detailed diagnostics of system configuration and operation as well as field

device diagnostics

♦ Can be used in a redundant ControlLogix® controller system

♦ Advanced Diagnostics automatically extracted and written to Logix Tag

Prosoft PLX51-HART-4I 4 Channel HART Input Module Features

Features

♦ Support for point-to-point networks with EtherNet/IP, Modbus TCP/IP or DNP3 (TCP/UDP) protocols

♦ Support for point to multipoint networks with EtherNet/IP and Modbus TCP/IP protocols

♦ Support for automatic configuration in Multidrop mode for Logix Controllers

♦ Support for PCCC (AB-ETH) protocol, allowing legacy controllers to easily interface to HART modules

♦ Support for Factory Talk View for point to point and multidrop HART devices

♦ EtherNet/IP enables a HART device to be added directly into a Rockwell Automation® Logix I/O tree

♦ Modbus TCP/IP enables a HART field device to be viewed as a Modbus Slave device

♦ DNP3 converts a HART field device into a DNP3 Outstation (slave) supporting Secure Authentication

♦ Support for point-to-multipoint network, maximum of 7 devices with EtherNet/IP protocol

♦ DTM (Device Type Manager) / HART Pass-through is available for simplifying device configuration and management using an FDT frame

♦ Built-in webserver provides detailed diagnostics of system configuration and operation as well as field device diagnostics

♦ Can be used in a redundant ControlLogix® controller system

♦ Advanced Diagnostics automatically extracted and written to Logix Tag

Prosoft PLX51-HART-4O 4 Channel HART Output Module

The PLX51-HART-4O allows users to easily connect their existing HART

compatible field devices to EtherNet/IP™, Modbus® TCP/IP, and DNP3

Ethernet networks. The module can be used to connect HART Output

devices such as valve positioners into an Ethernet network.

The PLX51-HART-4O supports up to 4 channels of HART communication,

as well as Analog 4-20 mA signals for real-time process variables to/from

the HART-compatible device.

Features

♦ Support for point-to-point networks with EtherNet/IP, Modbus TCP/IP

or DNP3 (TCP/IP and UDP) protocols

♦ Support for point to multipoint networks with EtherNet/IP and Modbus

TCP/IP protocols

♦ Support for automatic configuration in Multidrop mode for Logix Controllers

♦ Support for PCCC (AB-ETH) protocol, allowing legacy controllers to easily

interface to HART modules

♦ Support for Factory Talk View for point to point and multidrop HART devices

♦ EtherNet/IP enables a HART device to be added directly into a Rockwell

Automation® Logix I/O tree

♦ Modbus TCP/IP enables a HART field device to be viewed as a Modbus

Slave device

♦ DNP3 converts a HART field device into a DNP3 Outstation (slave) supporting

Secure Authentication

♦ DTM (Device Type Manager) / HART Pass-through is available for simplifying

device configuration and management using an FDT frame

♦ Built-in Web server provides detailed diagnostics of system configuration and

operation as well as field device diagnostics

♦ Can be used in a redundant ControlLogix® controller system

♦ Advanced Diagnostics automatically extracted and written to Logix Tags

Prosoft PLX51-PBS PROFIBUS DP Slave to EtherNet/IP™, Modbus® TCP/IP, or Modbus® Serial Gateway

Modbus® Serial networks for PROFIBUS DP networks by operating as a PROFIBUS

DP slave.

For easy integration to a Rockwell Automation Controller, the gateway and

configuration software create dynamic AOI’s based on the user configuration to add

logical tag names to the PLC project file. Thus, reducing programming time.

For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will

automatically map PROFIBUS DP data points to registers on a Modbus network.

With advanced tools such as a built in PROFIBUS DP packet capture utility,

PROFIBUS DP network commissioning time can be greatly reduced.

Dual Ethernet ports of the module can support either DLR (Device Level Ring)

topology, or can be used as an embedded switch for flexible installation options.

With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP

connections back to the processor, this module provides performance and data

throughput for even the most demanding of PROFIBUS applications.

As a PROFIBUS DP slave device, the module can emulate from 1 to as many as 10

slave DP nodes, providing up to 1536 bytes of Input and Output Cyclic I/O data

between EtherNet/IP devices and a PROFIBUS DP master. This eliminates the need

for using DPV1 messaging when more than 244 bytes of data needs to be exchanged

between a PROFIBUS master and an EtherNet/IP network.

Prosoft PLX51-PBS PROFIBUS DP Slave drive Features

Features

 Supports DLR for EtherNet/IP networks

 Support for either EtherNet/IP, Modbus TCP/IP, or Modbus Serial Communication networks

 PROFIBUS slave OR multi-slave support

 PROFIBUS packet capture tool built in

Configuration

The PLX50 Configuration Utility software is used for configuration and troubleshooting of

the module. The stand-alone configuration utility allows users to define the setup and

configuration of the PROFIBUS DP module, connections with Rockwell Automation controllers

and devices over EtherNet/IP, and build custom Add-On Instructions (AOIs) to be imported

into Studio 5000 applications.

With the ability to import custom AOI’s into the Studio 5000 environment and advanced

PROFIBUS DP tools such as the packet capture utility, commissioning time of a network

can be greatly reduced.

Prosoft PLX51-PBS EtherNet/IP™ Server (Class 1 Adapter)

EtherNet/IP™ Server (Class 1 Adapter)

As an EtherNet/IP server, the gateway operates as an Adapter with up to 4 Class 1 I/O

connections to a Controller (Scanner) on an EtherNet/IP network. The use of

EtherNet/IP Class 1 I/O connections for transfer of PROFIBUS DP cyclic data, provides

fast data transfer between networks for increased performance on time critical

PROFIBUS DP applications.

EtherNet/IP Client

As an EtherNet/IP client, the module can generate Get Attribute, Set Attribute, Set

Static, or Custom messages using either Class 3 messaging or UCCM messaging on

EtherNet/IP. With support for up to 5 unique devices on one module and a total of up to

50 mapping functions, this functionality allows EtherNet/IP devices such as Overload

Protection Relays and Variable Frequency Drives to be mapped onto a PROFIBUS DP

network.

Prosoft PLX51-PBS PROFIBUS DP Slave to EtherNet/IP™

Modbus TCP/IP

On a Modbus TCP/IP network, the module will operate as either a Modbus TCP/IP

Client or Server device.

As a Modbus TCP/IP client the module can be configured to automatically read/write all

PROFIBUS DP data with a slave device for easy setup and configuration, or the

Modbus Auxiliary Map feature will allow you to configure data transfer to customize the

mapping to meet specific application requirements.

As a Modbus TCP/IP Server all information from the PROFIBUS DP network is stored in

continuous registers in the module for easy configuration and efficient mapping of data

to a Modbus TCP/IP client.

Modbus Serial

On a Modbus Serial network the module will operate as either a Master or a Slave

device supporting either RS232 or RS485 communication networks.

As a Modbus Serial Master the module can be configured to automatically read/write all

PROFIBUS DP data with a slave device for easy setup and configuration, or the

Modbus Auxiliary Map feature will allow you to configure data transfer to customize the

mapping to meet specific application requirements.

As a Modbus Serial Slave all information from the PROFIBUS DP network is stored in

continuous registers in the module for easy configuration and efficient mapping of data

to an attached master device.

Prosoft PROFIBUS DP Slave

PROFIBUS DP Slave

The PROFIBUS DP Slave driver provides a powerful and easy-to-use interface between

a PROFIBUS DP network and other networks.

This slave implementation emulates up to 10 individual nodes on a PROFIBUS DP

network. It allows access to up to 1536 bytes of cyclic PROFIBUS Input data and up to

1536 bytes of cyclic PROFIBUS Output data.

For installations that require more than the 244 byte max cyclic PROFIBUS DP data

exchange, this module allows users to emulate up to 10 nodes, eliminating the need

for complex DPV1 Read/Write messages to a PROFIBUS DP node while improving

data throughput.

Additionally, the module can support the emulation on a PROFIBUS DP network for

some End-of-life legacy ProSoft solutions (5205-DFNT-PDPS, 5205-DFNT-PDPS, and

5105-MCM-PDPS) utilizing a selection in the PLX50 Configuration utility. By supporting

the legacy module Ident number (#05A5), the PLX51-PBS module can be used to

replace legacy ProSoft modules without having to reprogram the PROFIBUS DP master

configuration (note: changes may be required on EtherNet/IP, Modbus, or Modbus

TCP/IP configuration).

Prosoft PROFIBUS DP Master V1

PROFIBUS DP Master V1

Cyclic or acyclic data can be transferred with Class 1 or Class 2 DPV1 services,

allowing communication with slave devices supporting PROFIBUS DPV0 or V1

protocols. The gateway acts as an input/output link between the PROFIBUS network

and the EtherNet/IP protocol. Data transfer by the EtherNet/IP protocol is asynchronous

from data transfer on the PROFIBUS network.

 Easy-to-use drag and drop configuration interface via ProSoft PLX50 Configuration

Utility

 GSD file import library

 Monitoring and Modification of process data and DPV1 acyclic data

 Multi-drop on a PROFIBUS DPV1 network with other compatible devices

 Automatic project documentation, and Bus Parameter calculation

 Supports online slave diagnostics, and extended diagnostic data (DPV1)

 Auto baud detection at all valid PROFIBUS DPV1 rates up to 12 Mbps

 Master Status LED Indicators for Operations, Network Communication, Master

Token-Hold and Network Configuration.

 Up to 125 Slaves can be connected with a repeater

 Up to 1536 cyclic bytes input and 1536 bytes output data

 Supports Extended Diagnostic Data

 Alarm Handling (DPV1)

 Supports Sync and Freeze commands

 Supports PROFIdrive 3.1 compliant parameter read and write operations

 Supports Multicast and Broadcast telegrams (DPV1)