Technical data
Process gas temperature max. 600 °C
Measuring principle O₂ Zirconium oxide|MXP
Immersion depth/material 540 mm to 960 mm (others on request) /
Stainless steel (SS316TI)
Measuring principle COe MXP (mixed potential)
Ambient temperature Probe: -20°C to +70°C | Electronics: -20°C to
+55°C
O₂ – Measuring ranges Two freely selectable measuring ranges: 0-2 vol.%
to 0-21 vol.% (others on request)
COe – Measuring ranges 0 to 5000 ppm
Housing Probe: IP66 | Electronics: IP66
Type of protection II 2D Ex tb IIIC T133°C/141°C Db