Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Prosoft PLX31-MBTCP-SIE Industrial Ethernet Communication Gateway

ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet Gateway allows for

high-speed bi-directional data transfer between Modbus® TCP/IP controllers and Siemens® S7-400. S7-300. S7-200. S7-1200 and S7-1500 PACs.

In addition, the gateway has a number of features, including data prioritisation, that simplify integration, reduce commissioning time and optimise performance.

Functions

 The ProSoft Discovery Service utility www.cniacs.com allows your PC to view the gateway and edit its default IP address without being on the same subnet.

 Supports up to 20 simultaneous client and server connections to speed communications between devices such as HMIs, SCADA systems, power monitors, and traffic computers.

 In addition to S7 controllers, the Gateway can also be used with Siemens® S5 controllers with corresponding interfaces.

 The Gateway includes an SD card slot (SD card optional) for storing configuration files. It can be used for disaster recovery.

 Safe module configuration via Module Switch (v1.04 and higher).

 can exchange large amounts of data using up to 10.000 16-bit registers.

Prosoft PTQ-PDPMV1 PROFIBUS DP Master Network Interface Module

The PROFIBUS DPV1 master module is a powerful communication interface for Quantum ® processors.

Developed under licence from Quantum ®, the module uses proprietary backplane technology to enable powerful data exchange with the processor.

The module supports the full master specification according to IEC 61158. The ability to transfer acyclic parameter data via Class 1 or Class 2 DPV1 services.

Enables the processor to easily www.cniacs.com communicate with slave devices that support the PROFIBUS DPV0/V1 protocol.

This module is the input/output module between the PROFIBUS network and the processor. The processor data transfer is asynchronous to the I/O data transfer on the PROFIBUS network.

Features Benefits

Easy to configure and manage ♦ Includes ProSoft Configuration Builder software for designing, configuring, and monitoring PROFIBUS networks

PROFIBUS DPV1 Master FDT (Field Device Tool) Communication DTM (PROFIBUS comDTM) software included.

(PROFIBUS comDTM) software for connecting any compatible FDT software container, FDT device DTM, and applicable PROFIBUS slave devices

Configuration of PTQ modules and PROFIBUS networks via Ethernet

Industry Recognition ♦ Schneider Electric CAPP (Collaborative Automation Partner Programme) certification

PROFIBUS Trade Organisation (PTO) certified

Rugged and reliable ♦ Modules built on Siemens ASIC ASPC2 Step E and Infineon C165 microprocessors

Firmware can be quickly upgraded

Compliant with Unity HEC Hot Standby feature specification.

Supports up to 6 PTQ-PDPMV1 modules per rack (hot standby supports up to 4 modules)

implementation of up to four)

Supports extended diagnostic data, alarm indication and acknowledgement processing, multicast and broadcast messaging (DPV1)

Prosoft RLX2-IHNF 802.11abgn Fast Industrial HotSpot™

Features and Benefits

EtherNet/IP™ or Modbus® based PLC/PACs can use message commands to read diagnostic information from the radio, helping to reduce downtime when troubleshooting wireless networks.

802.11i, WPA-2 Personal/Enterprise with 128-bit AES encryption secures the network RADIUS security secures the network with advanced authentication and encryption Virtual Local Area Networks (VLANs) enable secure network segmentation

Network Address Translation (NAT) www.cniacs.com eliminates the need for machine builders to change IP addresses every time a machine is deployed

Quality of Service (QoS) provides data prioritisation for I/O control devices, video data, etc.

Ultra-fast roaming (less than 10 milliseconds) maintains seamless, high-speed connectivity with one or more devices on mobile equipment and machines such as cranes, AGVs, and transporters as they move between access points

IGMP snooping and packet filtering optimise UDP multicast traffic for superior EtherNet/IP I/O communications

Supports communication with multiple Ethernet devices when used with existing third-party wireless infrastructure

Supports AeroScout RTLS (Real-Time Location Service) tags by passing signals from the tag to the network

Supports Power over Ethernet (PoE) to reduce cabling costs

Disaster recovery feature allows radio configurations to be stored on a microSD card for quick replacement in the field

Serial network connectivity (Modbus, DNP 3. etc.) via 802.11 wireless network

Simple local and remote configuration, monitoring and wireless network diagnostics via IH browser utility or SNMP

16-Point Discrete Input Module in GE IC200MDL240 VersaMax I/O Family

Product Description

The IC200MDL240 is a 16-point discrete input module in the VersaMax I/O family, formerly manufactured by GE Intelligent Platforms and now owned by Emerson Automation. The module has sixteen (16) channels of positive or source inputs that accept 120 VAC input signal voltages with a signal range of 0-132 VAC, 47-63 Hz, and a minimum user input current of 7 mA per point.The module has a backplane 5VDC output current of 110 mA.

About the IC200MDL240

The IC200MDL240 is a discrete input module from the VersaMax I/O platform formerly manufactured by GE Intelligent Platforms and now manufactured by Emerson Automation. The module is a sixteen (16) point discrete input module that supports forward logic or source wiring configurations. It can be used to connect field and electrical devices that provide binary or on/off signal states, such as auxiliary contacts, proximity sensors, pushbutton devices, limit switches, and similar devices.

This 16-point module accepts an input signal voltage range of 0-132 VAC, 47-63 Hz, with a nominal signal voltage of 120 VAC and a minimum on-state current of 7 mA.The input channels are divided into two (2) groups of eight (8) channels each with a dedicated common channel. Its group-to-group isolation is rated at 250 VAC for 1 minute and 1500 VAC. Similarly, the module’s optical isolation (logically isolated user inputs) as well as rack ground isolation are rated at 1500 VAC (1 minute) and 250 VAC (continuous).

The turn-on response time for each channel is 1 cycle with a minimum of 2 ms, while the turn-off response time is 2 ms. The turn-on state voltage is 70-132 VAC, and the turn-off state voltage range is 0-40 VAC. In addition, the turn-on state current is a minimum of 7 mA, while the turn-off state current is a maximum of 1.5 mA.

The IC200MDL240 is a DIN-rail mount type that supports both horizontal and vertical orientations. When the module is mounted vertically, there is no performance derating, but there is a 132 VAC derating.

IC698PSA350 PACSystem RX7i High Capacity Power Module

Description:

The IC698PSA350 is a power supply module for the PACSystem RX7i platform, currently part of Emerson Automation, formerly known as the General Electric Intelligent Platform (GE IP). This power supply mounts to the RX7i universal backplane. It has an input voltage range of 85 to 264 VAC 47 to 63 Hz and 100 to 150 VDC with a maximum input power of 440 watts (typical) and 500 watts (maximum). All three (3) outputs (e.g., 5 VDC, 12 VDC, and -12 VDC) have a maximum output power of 350 watts and output currents of 0-60 amps, 0-12 amps, and 0-4 amps, respectively.

The IC698PSA350 is a high capacity www.cniacs.com power supply module for the PACSystem RX7i controller family. The module is used to provide backplane power, which the module uses to activate internal circuitry and begin operation. The power supply module occupies one slot in the chassis and can only be installed in slot 0 of the RX7i chassis.

The IC698PSA350 operates with input voltages of 85 to 264 VAC, 100 to 150 VDC, and an AC input frequency of 47 to 63 Hz. The module is rated at 120/240 VAC and 125 VDC, and has input power requirements of 440 watts typical and 500 watts maximum. The power factor of this power supply module is 0.99 when used for AC input power.

The IC698PSA350 is a single-slot power supply module that mounts in the leftmost slot of the RX7i chassis or slot 0. It is equipped with various LED status indicators. It is equipped with various LED status indicators to help identify the module’s operating status. These include the “Field OK”, “Output OK”, and “Over Temperature” LEDs. The power module has built-in protection circuits such as over-temperature and over-voltage protection and airflow protection. A 70 CFM forced air cooling fan under the system chassis provides cooling air to the power supply module. If a stoppage in airflow is detected, the overheat LED will illuminate.

The IC698PSA350 power supply is available in both Series A and Series B. The Series A power supply has an internally mounted 0.25″ x 1.25″ fuse, while the Series B power supply has a 5 x 20 metre fuse. The fuses installed are 8A/250V fuses.

PCH Engineering PCH 1026 Digital Wind Turbine Structure Vibration Monitor

Configuration and Setup

– Setup and configuration can be performed through the serial RS-232 port using the supplied Setup and Monitoring PC program, CHT 1012. All settings can be changed in the field.

– Setup and display can also be performed remotely from an external PC or controller (e.g., WTC or process controller) via an optional RS-485 connection.

– A log in the PC software records monitor-specific settings and identifies the instrument by its serial number.

Features

– 3 internal vibration sensors (accelerometers)

– Triaxial measurements in A, B and C directions

– Omni-directional tower monitoring

– Proven optimal tower monitoring

– Up to 4 different frequencies can be monitored independently, one frequency per transducer or up to 4 different frequencies per transducer

– Proven filter technology based on wind turbine application experience

– Measurement of RMS, Maximum, Peak or Peak values

– 1 – 4 independent industry standard 4-20mA outputs

– 4 independent alarm relays with programmable brake/break function and 1 system fault relay

– Programmable alarm thresholds and independent delay times for each alarm relay

– Internal continuous watchdog for sensors and electronic circuitry. Fault indication on system fault relay.

– Test functions for all sensors and electronic circuits.

– Designed for harsh environments including temperature, electrical noise interference and humidity.

– Customised monitoring algorithms are available to differentiate the customer from the competition.

Configuration

The PCH 1026 is a self-contained monitor in a sealed, rugged case. It requires only DC power and the required output connections to operate.

Required.The PCH 1026 is designed for low frequency monitoring applications.

Built-in vibration sensors in 3 directions: Built-in vibration sensors in 3 directions: X, Y and Z.

Includes test functions for all sensors and electronic circuits, as well as an internal watchdog for continuous self-monitoring functions.

The design of the PCH 1026 is based on a www.cniacs.com digital platform that provides customers with a wide range of solutions and allows for quick configuration and setup changes in the field.

Signal Conditioning

All signal conditioning is performed digitally.

This means that settings and configurations can be changed and verified via the included PC software programme (CHT1012).

Digital signal processing is performed by state-of-the-art DSP technology, ensuring accurate and efficient monitoring.

Selective monitoring of frequencies or bands of interest can be achieved by choosing from a variety of high and low pass filters. Simply select from which frequency to monitor.

The PCH 1026 has a wide range of filters that have been proven over many years of industry experience.

PCH Engineering External Bidirectional Low Frequency Accelerometer CHB 1101

The CHB 1101 transmitter is an external bi-directional low frequency accelerometer for use with the PCH 1026 mk2 wind turbine and structural vibration monitor.

The external bi-directional accelerometer is used for advanced nacelle monitoring with distributed pick-up points.

Separate cables with integrated D-Sub and M12 connectors make installation and connection of the vibration monitor very simple.

Easy to install

The CHB 1101 has an internal www.cniacs.com memory chip which stores factory information: serial number, model number, sensitivity and self-test parameters.

When the CHB 1101 is connected, the monitor reads the information in the memory chip and automatically adapts to the settings of the particular sensor.

This means that the accelerometer can be freely replaced without having to manually change the parameters.

The monitor reads the chip every 30 seconds to verify that the accelerometer is still connected and recognised.

The monitor will stabilise for 20 seconds after power is applied.

The stabilisation time after disconnecting/connecting the CHB 1101 is 3 seconds. During settling, the PCH 1026 Mk2 will perform a self-test of the internal and external accelerometers.

Self-Test

The monitor will issue a system error message if the self-test fails or the accelerometer is disconnected.

Accelerometers must be specified in the PCH 1026 Vibration Monitor setup to use this feature.

The CHB 1101 accelerometer is an optional feature of the PCH 1026 Mk2 Wind Turbine and Structural Vibration Monitor.

IC694CEE001 Single Slot RX3i Carrier/Expansion Module

The IC694CEE001 protects critical applications where any single point of failure affecting more than one I/O module is unacceptable.

The RX3i IO is designed for mission-critical discrete and process applications.

With advanced diagnostics and outstanding flexibility, this rack-based IO offers a wide range of standard and advanced IOs.

The IC694CEE001 carrier connects a remote node consisting of an RX3i I/O module to a PROFINET I/O local area network (LAN).

and connects it to the RX3i CEP001 carrier. This allows you to add another RX3i IC694 I/O module to the remote node.

The main remote I/O functions of the www.cniacs.com IC694CEE001 carrier include: scanning of all modules within the remote node (input and output scanning).

Publishing data to PROFINET IO controllers on the PROFINET network during a user-specified production cycle.

Receiving data from PROFINET IO controllers on the PROFINET network according to the production timeframe defined by the customer; and

Monitoring PROFINET communication and module configuration between PROFINET I/O controllers and modules in remote nodes.

Manage the status of the I/O in the event of a communication outage; and issue fault messages (such as alarms and diagnostics), alarms and diagnostics) to the controller.

NOTE: The USB port is for firmware upgrades only and should not be used for permanent connections. The CEP Carrier requires a user-supplied +24 VDC power supply.

Functions

Scans all modules within a remote node (input and output scanning)

Publish data to the PROFINE IO controller on the PROFINET network during a user-specified production cycle

Receives data from PROFINET IO controllers on the PROFINET network during a user-specified production cycle

Manage PROFINET communications and module configuration between PROFINET IO controllers and modules within remote nodes.

Manage the status of I/O in the event of a communication outage

Publishing fault messages (alarms, diagnostics, etc.) to PROFINET IO controllers

Comprehensive programming and configuration services for all supported RX3i IO modules using Proficy Machine Edition

Supports daisy-chained/linear, star or ring (redundant media) network topologies

Two switched Ethernet ports: two eight-core RJ-45 shielded twisted-pair 10/100 Mbps copper interfaces

One USB port for field updating firmware using WinLoader

IS220YDIAS1A Discrete Contact Input/Output Module

Product Description.

The IS220YDIAS1A is a discrete contact input/output module from General Electric.

This module is designed for gas and steam industrial control in the Mark VIe Speedtronic control system.

The Mark VIe was the last Speedtronic system designed by GE and was one of a series of industrial control systems marketed under the Speedtonic name.

The IS220YDIAS1A is part of the Mark IVe control system or Mark VIeS functional safety system.

As an I/O block, it is designed to be plugged into specific terminal blocks such as the IS200STCIS1A and 2A, IS400STCIS1A or 2A or IS400TBCIS2C.

The IS220YDIAS1A has an on-board power www.cniacs.com supply with a nominal voltage of 28.0 VDC.

The contact inputs and contact wetted outputs have a maximum nominal voltage of 32 VDC.

The IS220YDIAS1A has both UL and CE approvals. It can be used in both hazardous and non-hazardous locations.

Hazardous location use ratings can be found in documents such as GE’s GEH-6725.

This I/O module is designed for use in ambient conditions from -35 to 65 degrees Celsius.

The IS220YDIAS1A is a well-designed module that can be easily mounted on the IS230 terminal board.

The simplicity of installation and availability of documentation make this module ideal for most applications.

Numerous indicator LEDs on the front of the module allow the user to read the status of the IS220YDIAS1A discrete input module.

VMIVME-2120 64-bit High Voltage Digital Output Module

Features

– 64-bit high voltage output

– High current driver (600 mA sink current)

– Inrush current auto shutdown protection option

– Thermal shutdown protection www.cniacs.com option for driving incandescent lamps or inductive loads

– High breakdown voltage (55 V)

– Output clamp diode for inductive flyback protection

– Compatible with intelligent I/O controllers

– Built-in test logic for fault isolation

– Highly reliable DIN-type I/O connectors

– 8-, 16-, or 32-bit transmission

– Dual Eurocard form factor

– Separate board address decoding for control and data registers

– Optional pull-up resistors for electronic switch outputs

– Optional TTL outputs

– Front Panel with Fault LED

Functional Features

Compatibility: Compatible with VMEbus specification.

Double height form factor.

Output Connector Type: Dual 64-pin connector DIN 41612.

Output Organisation Eight ports, eight bits wide.

Addressable to any address within the Short-Circuit Monitor or Short-Circuit Unprivileged I/O map. Control and Status Register (CSR) addresses are independently selectable.

Address Modifier Codes: Short-circuit supervisory or short-circuit unprivileged I/O access can be selected via jumpers.

Factory configured for short-supervised I/O access.

Addressing Scheme: Eight ports can be individually addressed on 8-bit, 16-bit, or 32-bit boundaries.

CSR’s separate board address decoder allows hardware control addresses to be grouped for software efficiency.

Data Transfer Bus: A16: D8. D16. D32

Built-in Test: This product supports offline and real-time fault detection and isolation. Offline mode can be enabled by writing the CSR Set Test Mode bit.

When test mode is enabled, all outputs are off. When test mode is enabled, all outputs are off.