Beckhoff ED2032 | EtherCAT Terminal, 2-channel digital output

The ED2032 digital output terminal connects the binary control

signals from the automation device on to the actuators at the

process level with electrical isolation. The EtherCAT Terminal

contains two channels whose signal state is indicated by light

emitting diodes (status LEDs).

An overload detected by the integrated diagnostics can be

evaluated in the controller and is also indicated by LEDs. A

diagnostic bit is set for the affected channel if there is an

overload. The diagnostics serve to simplify the maintenance

of the application. The power contacts are looped through.

In the ED2032 the outputs are supplied via the 24 V DC power

contact. They are electrically isolated from the fieldbus side.

Special features:

• suitable for controlling different types of loads:

• resistive loads (e.g., resistors)

• inductive loads (e.g., relays, contactors, valves)

• capacitive loads

• max. output current of 2 A per channel

• integrated diagnostic option: overload

• short-circuit proof outputs: protection against overload or short

circuit

• reverse polarity protection in the event of incorrect polarity of the

supply voltage

The ED series EtherCAT Terminals have push-in connection technology

which makes wiring easy and tool-free.

Beckhoff EL2032 EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, with diagnostics

The EL2032 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation. The EtherCAT Terminal

has two channels that indicate their signal state via light emitting

diodes. The integrated diagnostics can be evaluated in the controller

and is indicated by the LEDs. The EL2032 allows direct connection

of two 3-wire actuators.

Special features:

• Connection of different load types possible (ohmic, inductive,

lamp load)

• Max. output current 2 A per channel

• Short-circuit-proof outputs and reverse polarity protection

• Integrated diagnostics capability

• Short-circuit detection per channel

• Line break detection per channel

Beckhoff EL2014 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, with extended diagnostics

The EL2014 digital output terminal connects the binary 24 V DC control

signals from the automation device on to the actuators at the process

level with electrical isolation. The EtherCAT Terminal contains four

channels that indicate its signal state by means of light emitting diodes.

The integrated diagnostics can be evaluated in the controller and is

indicated by the LEDs. Maintenance of the application is simplified by

the diagnostics. The power contacts are connected through.

The reference potential of the outputs is the 0 V DC power contact.

The outputs are supplied via the 24 V DC power contact.

Special features:

• Connection of different load types possible (ohmic, inductive, lamp load)

• Max. output current 0.5 A per channel

• Overload and short-circuit proof outputs and reverse polarity protection

• Integrated diagnostics option, including

• Short-circuit detection per channel

• Line break detection per channel

• Overcurrent per channel

• Overtemperature

• Voltage loss and undervoltage

• Parameterizable output behavior in case of bus error (safe state)

Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i

The ELX2008 digital output terminal enables the direct connection

of intrinsically safe actuators located in hazardous areas classified

zone 0/20 or 1/21. The ELX2008 supplies an output voltage of 24

V DC and a maximum output current of 30 mA per channel. 

The signal state of each channel is indicated by a light emitting diode.

EtherCAT terminals of the ELX series must always be operated in

conjunction with the ELX9560 power supply terminal. This terminal

generates an electrically isolated output voltage (24 V EX) from the

input voltage (24 V DC) for supplying the subsequent ELX terminals.

If a new power supply is required, the combination of an ELX9410

and an ELX9560 can be used so that further ELX terminals can be

added.

The ELX terminal segment must be terminated with one ELX9012.

two ELX9410 or one EK1110. The use of two ELX9410 allows the

use of EL terminals behind ELX terminals. With the EK1110. the

terminal segment can be continued via an EtherCAT cable, 

for example to implement cable redundancy.

Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i

The ELX2008 digital output terminal enables the direct connection

of intrinsically safe actuators located in hazardous areas classified

zone 0/20 or 1/21. The ELX2008 supplies an output voltage of 24

V DC and a maximum output current of 30 mA per channel. 

The signal state of each channel is indicated by a light emitting diode.

EtherCAT terminals of the ELX series must always be operated in

conjunction with the ELX9560 power supply terminal. This terminal

generates an electrically isolated output voltage (24 V EX) from the

input voltage (24 V DC) for supplying the subsequent ELX terminals.

If a new power supply is required, the combination of an ELX9410

and an ELX9560 can be used so that further ELX terminals can be

added.

The ELX terminal segment must be terminated with one ELX9012.

two ELX9410 or one EK1110. The use of two ELX9410 allows the

use of EL terminals behind ELX terminals. With the EK1110. the

terminal segment can be continued via an EtherCAT cable, 

for example to implement cable redundancy.

Beckhoff ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

The ED2008 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation. The EtherCAT Terminal

has eight channels that indicate their signal state via light emitting

diodes (status LEDs). The power contacts are looped through

internally. In the ED2008 the outputs are supplied via the 24 V

DC power contact.

Special features:

• suitable for controlling different types of loads:

• resistive loads (e.g., resistors)

• inductive loads (e.g., relays, contactors, valves)

• capacitive loads

• max. output current of 0.5 A per channel

• positive switching

• short-circuit proof outputs: protection against overload or short

circuit

• reverse polarity protection in the event of incorrect polarity of 

the supply voltage

The ED series EtherCAT Terminals have push-in connection technology

which makes wiring easy and tool-free.

Beckhoff ELX2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 45 mA, Ex i

The ELX2002 digital output terminal enables the direct connection

of intrinsically safe actuators located in hazardous areas classified

zone 0/20 or 1/21. The ELX2002 supplies an output voltage of 

24 V DC and a maximum output current of 45 mA perchannel,

sum current is 80 mA. The signal state of each channel is indicated

by a light emitting diode.

EtherCAT terminals of the ELX series must always be operated in

conjunction with the ELX9560 power supply terminal. This terminal

generates an electrically isolated output voltage (24 V EX) from the

input voltage (24 V DC) for supplying the subsequent ELX terminals.

If a new power supply is required, the combination of an ELX9410

and an ELX9560 can be used so that further ELX terminals can be

added.

The ELX terminal segment must be terminated with one ELX9012.

two ELX9410 or one EK1110. The use of two ELX9410 allows the

use of EL terminals behind ELX terminals. With the EK1110. the

terminal segment can be continued via an EtherCAT cable,

for example to implement cable redundancy.

TMEIC TM21-TG Series 2-Pole Generator

The TM21-TG Series generators are 2-pole, air-cooled generators.

Features and Benefits

Design Feature

• Flexibility

• New Compact Design

• Lower Noise and Less Vibration

• Reliability

• Maintenance

• Installation and Commissioning

Customer Benefit

• Custom-designed to meet unique application requirements and

global standards

• Extensive electrical field and heat transfer analysis enables a more

efficient footprint

• Spring support system and optimized rotor design reduce frequency

vibration and noise impact

• Advanced VPI insulation and solid pole rotor construction ensure

performance and surge tolerance

• Brushless AC exciter system minimizes wear and simplifies routine

maintenance

• Bracket-type generator allows transport and setup without dismantling,

reducing installation time

TMEIC TM21-TG Series 4-Pole Generator for Turbine Drive

TMEIC’s 4-Pole, air-cooled generators are custom designed to meet each

customer’s requirements.TMEIC’s 4-Pole, air-cooled generators are custom

designed to meet each customer’s requirements.

Features and Benefits

Design Feature

• Flexibility

• New Compact Design

• Lower Noise and Less Vibration

• Reliability

• Maintenance

• Installation and Commissioning

Customer Benefit

• Custom-designed to meet unique application requirements and global

standards

• Extensive electrical field and heat transfer analysis enables a more efficient

footprint

• Spring support system and optimized rotor design reduce frequency vibration

and noise impact

• Advanced VPI insulation and solid pole rotor construction ensure performance

and surge tolerance

• Brushless AC exciter system minimizes wear and simplifies routine maintenance

• Bracket-type generator allows transport and setup without dismantling, reducing

installation time

TMEIC Turbine Generator Empowering the Future

Why Choose TMEIC Generators?

Flexibility

TMEIC designs, manufactures and tests each

generator to your specific needs.

• Footprint & critical dimensions matched for easy replacement

of existing machines

• Complies with major global standards (NEMA, IEEE, IEC, API)

• High Performance (High Efficiency, Short-circuit ratio,

impedance, etc.)

• Multiple design options (Cooling system, excitation system

types, etc.)

Reliability

TMEIC generators offer world class performance

• Every rotor is high speed multi-plane balanced

• TMEIC insulation system with VPI technology ensures a

reliable operation

• An exclusive spring system design ensures low vibration and

harmonics

• Fully factory assembled and tested

• Forged shaft of special alloy steel for high speed operation

• Three diodes in parallel plus two in series, in six arms,

incorporating a rectifier with superior reliability

Low Maintenance

• TMEIC’s excitation systems incorporate a brushless exciter

eliminating brush maintenance

• Standard sleeve bearings include a floating labyrinth seal to

eliminate oil leakage

• TMEIC’s Generators ship fully assembled to facilitate

transportation, installation and for protection of internal

components