Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Beckhoff EL2869 | EtherCAT Terminal, 16-channel digital output

The EL2869 digital output terminal connects the binary control signals

of the automation device to the actuators at process level with

electrical isolation. The EtherCAT Terminal contains sixteen channels,

which indicate their signal status by means of LEDs.

The integrated diagnostics can be evaluated in the controller and are

indicated by the LEDs. A diagnostic bit is set for the affected channel

if there is an overload. The diagnostics serve to simplify the

maintenance of the application. The power contacts are looped through.

The outputs of the EL2869 are supplied via the 24 V power contact.

The outputs are electrically isolated from the fieldbus side.

Special features:

• connection of different load types possible (resistive, inductive, lamp load).

• max. output current of 0.5 A per channel

• short-circuit proof outputs and reverse polarity protection

• integrated diagnostic possibility overload

• parameterizable output behavior in case of bus error (safe state)

• tool-free connection due to direct plug-in technology for solid conductors

Beckhoff ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A

The ED2828 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation.

The EtherCAT Terminal contains eight channels whose signal state

is indicated by light emitting diodes (status LEDs).

The power contacts are looped through.

In the EL2828 the outputs are supplied via the 24 V DC power

contact.

Special features:

• suitable for controlling different types of loads:

• resistive loads (e.g., resistors)

• inductive loads (e.g., relays, contactors, valves)

• capacitive loads

• max. output current of 2 A per channel (∑ 10 A)

• short-circuit proof outputs: protection against overload or short

circuit

• reverse polarity protection in the event of incorrect polarity of

the supply voltage

The ED series EtherCAT Terminals have push-in connection technology

which makes wiring easy and tool-free.

Beckhoff EL2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A

The EL2828 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation.

The EtherCAT Terminal contains eight channels whose signal state

is indicated by LEDs.

The power contacts are connected through.

In the EL2828 the outputs are supplied via the 24 V DC power contact.

Special features:

• Connection of different load types possible (ohmic, inductive, capacitive)

• Max. output current of 2 A per channel (∑ 10 A)

• Overload and short-circuit proof outputs and reverse polarity protection

• Tool-free connection by direct plug-in technology for solid wire conductors

Beckhoff EL2819 | EtherCAT Terminal, 16-channel digital output

The EL2819 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators

at the process level with electrical isolation.

The EtherCAT Terminal has 16 channels, whose signal states are

indicated by LEDs. The integrated diagnostics can be evaluated

in the controller and is indicated by the LEDs. Maintenance of

the application is simplified by the diagnostics.

The power contacts are connected through. 

The reference ground for the outputs is the 0 V DC power contact.

The outputs are electrically isolated from the fieldbus side.

Special features:

• Connection of different load types possible (ohmic, inductive,

lamp load)

• Max. output current 0.5 A per channel

• Short-circuit-proof outputs and reverse polarity protection

• Integrated diagnostics option, including

• Short-circuit detection per channel

• Wire breakage per channel

• Overcurrent per channel

• Overtemperature

• Voltage loss and undervoltage

• Parameterizable output behavior in case of bus error (safe state)

• Tool-free connection by direct plug-in technology for solid wire

conductors

Beckhoff ED2807 | EtherCAT Terminal, 32-channel digital output

The ED2807 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation. The EtherCAT Terminal

has 32 channels that indicate their signal state via light emitting

diodes (status LEDs). The power contacts are looped through

internally. In the ED2807 the outputs are supplied via the 24 V

DC power contact.

The connection technology is optimized for single-ended signals

(common reference point). To ensure error-free operation, all

connected components must use the same ground reference

as the ED2807.

Special features:

• suitable for controlling different types of loads:

• resistive loads (e.g., resistors)

• inductive loads (e.g., relays, contactors, valves)

• capacitive loads

• max. output current of 0.5 A per channel (∑ 10 A)

• positive switching

• short-circuit proof outputs: protection against overload or short

circuit

• reverse polarity protection in the event of incorrect polarity of the

supply voltage

The ED series EtherCAT Terminals have push-in connection technology

which makes wiring easy and tool-free.

Beckhoff EL2407 | EtherCAT Terminal, 32-channel digital output, 24 V DC, 0.5 A

The EL2407 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation.

The EtherCAT Terminal has 32 channels, whose signal states are

indicated by LEDs. The power contacts are connected through.

The connection technology is particularly suitable for single-ended

inputs. All components have to use the same reference point as

the EL2407. In the EL2407 the outputs are supplied via the 24 V

DC power contact.

Special features:

• connection of different load types possible (ohmic, inductive, lamp load)

• max. output current 0.5 A per channel (∑ 10 A)

• overload and short-circuit proof outputs and reverse polarity protection

• tool-free connection by direct plug-in technology for solid wire conductors

• space-saving use in the control cabinet

• direct connection of multi-channel actuators in 1-wire connection technology

in the smallest space

Beckhoff EL2409 | EtherCAT Terminal, 16-channel digital output

The EL2409 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators 

at the process level with electrical isolation.

The EtherCAT Terminal has 16 channels, whose signal states are

indicated by LEDs. The power contacts are connected through.

The connection technology is particularly suitable for single-ended

inputs. All components have to use the same reference point as

the EL2409. In the EL2409 the outputs are supplied via the 24 V

DC power contact.

Special features:

• connection of different load types possible (ohmic, inductive, lamp load)

• max. output current 0.5 A per channel

• overload and short-circuit proof outputs and reverse polarity protection

• tool-free connection by direct plug-in technology for solid wire conductors

• space-saving use in the control cabinet

• direct connection of multi-channel actuators in 1-wire connection technology in the smallest space

• increased packing density with 16 connection points in the housing of a 12 mm terminal block

Beckhoff EL2809 | EtherCAT Terminal, 16-channel digital output, 24 V DC, 0.5 A

The EL2809 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation.

The EtherCAT Terminal has 16 channels, whose signal states are

indicated by LEDs. The power contacts are connected through.

The connection technology is particularly suitable for single-ended

inputs. All components have to use the same reference point as

the EL2809. In the EL2809 the outputs are supplied via the 24 V

DC power contact.

Special features:

• Connection of different load types possible (ohmic, inductive,

lamp load)

• Max. output current 0.5 A per channel

• Overload and short-circuit proof outputs and reverse polarity

protection

• Tool-free connection by direct plug-in technology for solid wire

conductors

• Space-saving use in the control cabinet

• Direct connection of multi-channel actuators in 1-wire connection

technology in the smallest space

• Increased packing density with 16 connection points in the housing

of a 12 mm terminal block

Beckhoff EL2808 | EtherCAT Terminal, 8-channel digital output

The EL2808 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation.

The EtherCAT Terminal contains eight channels whose signal state

is indicated by LEDs.

The power contacts are connected through. In the EL2808 the

outputs are supplied via the 24 V DC power contact.

Special features:

• Connection of different load types possible (ohmic, inductive,

lamp load)

• Max. output current 0.5 A per channel

• Overload and short-circuit proof outputs and reverse polarity

protection

• Tool-free connection by direct plug-in technology for solid wire

conductors

• Increased packing density with 16 connection points in the

housing of a 12 mm terminal block

Beckhoff EL2798 | EtherCAT Terminal, 8-channel solid state relay output

The digital EL2798 EtherCAT Terminal provides eight switches

that can be used like a relay contact for AC/DC voltages.

The electronic switch is realized through high-performance

MOSFET transistors with low on-resistance.

The switch itself is not short circuit proof, but thanks to its

high pulse current capability it can cope with current until

an external fuse is triggered. The wear resistance increases

the availability of the application. Ohmic and slightly inductive

loads can be switched up to a rated voltage of 30 V AC/DC.

Purely ohmic loads can be switched up to 48 V DC rated

voltage. High peak voltages and electromagnetic interference

pulses are prevented. The EL2798 features potential-free

contacts; the power contacts are passed through.

Special features:

• 8 x make contacts as substitutes for relay contacts

• switching of ohmic loads up to a rated voltage of 30 V

AC/48 V DC

• switching of slightly inductive loads up to a rated voltage

of 30 V AC/DC

• max. output current of 2 A per channel (∑ 10 A)

• potential-free

Search for products

Back to Top
Product has been added to your cart