Beckhoff ED2034 | EtherCAT Terminal, 4-channel digital output

The ED2034 digital output terminal connects the binary control signals

from the automation device on to the actuators at the process level

with electrical isolation. The EtherCAT Terminal contains four channels

whose signal state is indicated by light emitting diodes (status LEDs).

An overload detected by the integrated diagnostics can be evaluated

in the controller and is also indicated by LEDs. A diagnostic bit is set

for the affected channel if there is an overload. The diagnostics serve

to simplify the maintenance of the application. The power contacts

are looped through.

In the ED2034 the outputs are supplied via the 24 V DC power contact.

They are electrically isolated from the fieldbus side.

Special features:

• suitable for controlling different types of loads:

• resistive loads (e.g., resistors)

• inductive loads (e.g., relays, contactors, valves)

• capacitive loads

• max. output current of 2 A per channel

• integrated diagnostic option: overload

• short-circuit proof outputs: protection against overload or short circuit

• reverse polarity protection in the event of incorrect polarity of the supply

voltage

The ED series EtherCAT Terminals have push-in connection technolog

which makes wiring easy and tool-free.

Beckhoff EL2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with diagnostics

The EL2034 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators

at the process level with electrical isolation. The EtherCAT

Terminal has four channels that indicate their signal state via

light emitting diodes. The integrated diagnostics can be

evaluated in the controller and is indicated by the LEDs.

The EL2034 allows direct connection of four 2-wire actuators.

Special features:

• Connection of different load types possible (ohmic, inductive,

lamp load)

• Max. output current 2 A per channel

• Short-circuit-proof outputs and reverse polarity protection

• Integrated diagnostics capability

• Short-circuit detection per channel

• Line break detection per channel

Beckhoff ED2032 | EtherCAT Terminal, 2-channel digital output

The ED2032 digital output terminal connects the binary control

signals from the automation device on to the actuators at the

process level with electrical isolation. The EtherCAT Terminal

contains two channels whose signal state is indicated by light

emitting diodes (status LEDs).

An overload detected by the integrated diagnostics can be

evaluated in the controller and is also indicated by LEDs. A

diagnostic bit is set for the affected channel if there is an

overload. The diagnostics serve to simplify the maintenance

of the application. The power contacts are looped through.

In the ED2032 the outputs are supplied via the 24 V DC power

contact. They are electrically isolated from the fieldbus side.

Special features:

• suitable for controlling different types of loads:

• resistive loads (e.g., resistors)

• inductive loads (e.g., relays, contactors, valves)

• capacitive loads

• max. output current of 2 A per channel

• integrated diagnostic option: overload

• short-circuit proof outputs: protection against overload or short

circuit

• reverse polarity protection in the event of incorrect polarity of the

supply voltage

The ED series EtherCAT Terminals have push-in connection technology

which makes wiring easy and tool-free.

Beckhoff EL2032 EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, with diagnostics

The EL2032 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation. The EtherCAT Terminal

has two channels that indicate their signal state via light emitting

diodes. The integrated diagnostics can be evaluated in the controller

and is indicated by the LEDs. The EL2032 allows direct connection

of two 3-wire actuators.

Special features:

• Connection of different load types possible (ohmic, inductive,

lamp load)

• Max. output current 2 A per channel

• Short-circuit-proof outputs and reverse polarity protection

• Integrated diagnostics capability

• Short-circuit detection per channel

• Line break detection per channel

Beckhoff EL2014 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, with extended diagnostics

The EL2014 digital output terminal connects the binary 24 V DC control

signals from the automation device on to the actuators at the process

level with electrical isolation. The EtherCAT Terminal contains four

channels that indicate its signal state by means of light emitting diodes.

The integrated diagnostics can be evaluated in the controller and is

indicated by the LEDs. Maintenance of the application is simplified by

the diagnostics. The power contacts are connected through.

The reference potential of the outputs is the 0 V DC power contact.

The outputs are supplied via the 24 V DC power contact.

Special features:

• Connection of different load types possible (ohmic, inductive, lamp load)

• Max. output current 0.5 A per channel

• Overload and short-circuit proof outputs and reverse polarity protection

• Integrated diagnostics option, including

• Short-circuit detection per channel

• Line break detection per channel

• Overcurrent per channel

• Overtemperature

• Voltage loss and undervoltage

• Parameterizable output behavior in case of bus error (safe state)

Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i

The ELX2008 digital output terminal enables the direct connection

of intrinsically safe actuators located in hazardous areas classified

zone 0/20 or 1/21. The ELX2008 supplies an output voltage of 24

V DC and a maximum output current of 30 mA per channel. 

The signal state of each channel is indicated by a light emitting diode.

EtherCAT terminals of the ELX series must always be operated in

conjunction with the ELX9560 power supply terminal. This terminal

generates an electrically isolated output voltage (24 V EX) from the

input voltage (24 V DC) for supplying the subsequent ELX terminals.

If a new power supply is required, the combination of an ELX9410

and an ELX9560 can be used so that further ELX terminals can be

added.

The ELX terminal segment must be terminated with one ELX9012.

two ELX9410 or one EK1110. The use of two ELX9410 allows the

use of EL terminals behind ELX terminals. With the EK1110. the

terminal segment can be continued via an EtherCAT cable, 

for example to implement cable redundancy.

Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i

The ELX2008 digital output terminal enables the direct connection

of intrinsically safe actuators located in hazardous areas classified

zone 0/20 or 1/21. The ELX2008 supplies an output voltage of 24

V DC and a maximum output current of 30 mA per channel. 

The signal state of each channel is indicated by a light emitting diode.

EtherCAT terminals of the ELX series must always be operated in

conjunction with the ELX9560 power supply terminal. This terminal

generates an electrically isolated output voltage (24 V EX) from the

input voltage (24 V DC) for supplying the subsequent ELX terminals.

If a new power supply is required, the combination of an ELX9410

and an ELX9560 can be used so that further ELX terminals can be

added.

The ELX terminal segment must be terminated with one ELX9012.

two ELX9410 or one EK1110. The use of two ELX9410 allows the

use of EL terminals behind ELX terminals. With the EK1110. the

terminal segment can be continued via an EtherCAT cable, 

for example to implement cable redundancy.

Beckhoff ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

The ED2008 digital output terminal connects the binary 24 V DC

control signals from the automation device on to the actuators at

the process level with electrical isolation. The EtherCAT Terminal

has eight channels that indicate their signal state via light emitting

diodes (status LEDs). The power contacts are looped through

internally. In the ED2008 the outputs are supplied via the 24 V

DC power contact.

Special features:

• suitable for controlling different types of loads:

• resistive loads (e.g., resistors)

• inductive loads (e.g., relays, contactors, valves)

• capacitive loads

• max. output current of 0.5 A per channel

• positive switching

• short-circuit proof outputs: protection against overload or short

circuit

• reverse polarity protection in the event of incorrect polarity of 

the supply voltage

The ED series EtherCAT Terminals have push-in connection technology

which makes wiring easy and tool-free.

Beckhoff ELX2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 45 mA, Ex i

The ELX2002 digital output terminal enables the direct connection

of intrinsically safe actuators located in hazardous areas classified

zone 0/20 or 1/21. The ELX2002 supplies an output voltage of 

24 V DC and a maximum output current of 45 mA perchannel,

sum current is 80 mA. The signal state of each channel is indicated

by a light emitting diode.

EtherCAT terminals of the ELX series must always be operated in

conjunction with the ELX9560 power supply terminal. This terminal

generates an electrically isolated output voltage (24 V EX) from the

input voltage (24 V DC) for supplying the subsequent ELX terminals.

If a new power supply is required, the combination of an ELX9410

and an ELX9560 can be used so that further ELX terminals can be

added.

The ELX terminal segment must be terminated with one ELX9012.

two ELX9410 or one EK1110. The use of two ELX9410 allows the

use of EL terminals behind ELX terminals. With the EK1110. the

terminal segment can be continued via an EtherCAT cable,

for example to implement cable redundancy.

Beckhoff EL1918 | EtherCAT Terminal, 8-channel digital input

The EL1918 TwinSAFE component is a digital input terminal for sensors

with potential-free contacts for 24 V DC. The EtherCAT terminal has eight

fail-safe inputs, which are transmitted via FSoE to a TwinSAFE Logic-capable

component.

The EL1918 has safety parameters to specifically adapt the functionality to

the respective safety requirements. Thus, for example,test pulses can be

configured with fine granularity for all eight channels in order to be able

to connect as many types of sensors as possible.

The safety parameters are not stored directly on the component, but are

transmitted to the input terminal via a TwinSAFE Logic capable component

when the safety application is started. This simplifies service procedures,

because the component can simply be replaced.

Special features EL1918:

• 8 safe inputs

• integrated TwinSAFE Logic (functionality similar to the EL6910)

• up to 128 safe connections

• fine granular configuration of the test pulses of the individual channels

For applications without integrated TwinSAFE Logic, the EL1918-2200 can

be used.

Special features EL1918-2200:

• 8 safe inputs

• fine granular configuration of the test pulses of the individual channels

• TwinSAFE Logic not integrated