Beckhoff ED3361 | EtherCAT Terminal, 1-channel analog input

The ED3361 analog input terminal enables the direct connection of

a resistance bridge (strain gauge – SG) or a load cell using 4 wire

or 6-wire connection technology. It records the ratio of the bridge

voltage UBridge to the measured supply voltage USense and outputs

 the calculated load value as a process value based on the terminal

settings. This enables precise recording of weights, torques, and

vibrations.

The terminal also has a digital input and a digital output. The digital

input can be used, for example, to trigger a tare function. The digital

output can be switched on the basis of local evaluations in the terminal,

for example depending on the measured value of

the resistance bridge.

Special features:

• integrated, switchable 5 V/10 V bridge supply UExc, generated from

the power contacts

• parallel connection of bridges possible due to powerful bridge supply

• sampling rate of 10 ksps

• additional digital inputs and outputs for local trigger conditions

The ED series EtherCAT Terminals have push-in connection technology

which makes wiring easy and tool-free.

Beckhoff EL3356-0090 | EtherCAT Terminal, 1-channel analog input

The analog EL3356-0090 input terminal enables direct connection

of a resistor bridge or load cell in a 4- or 6-wire connection technology.

The ratio between the bridge voltage UD and the supply voltage UREF

is determined simultaneously in the input circuit and the final load value

is calculated as a process value on the basis of the settings in the terminal.

With automatic self-calibration (can be deactivated) and dynamic filters

the terminal with measuring cycles of 10 ms can be used for slow weighings

with high precision.

With the aid of the TwinSAFE SC technology (TwinSAFE Single Channel) it

is possible to make use of standard signals for safety tasks in any network

or fieldbus. To do this, EtherCAT I/Os from the areas of analog input, position

measurement or communication (4…20 mA, incremental encoder, IO-Link,

etc.) are extended by the TwinSAFE SC function. The properties typical for

the signals and the standard functions of the I/O components are retained.

TwinSAFE SC I/Os differ optically from standard I/Os by a yellow stripe on

the front of the housing.

The TwinSAFE SC technology enables communication via a TwinSAFE protocol. 

These connections can be distinguished from the usual secure communication

via Safety over EtherCAT.

The data from the TwinSAFE SC components is fed via a TwinSAFE protocol to

the TwinSAFE Logic, where it can be used in the context of safety-relevant

applications. Detailed examples confirmed/calculated by the TÜV SÜD for the

correct application of the TwinSAFE SC components and the respective normative

classifications can be found in the TwinSAFE application manual.

Eaton EGR5000 Generator relay core features

Generator relay core features

• Microprocessor-based protection with monitoring and control for medium to large

sized generators.

• Complete metering of voltage, currents, power, energy, minimum/maximum and

demand functions.

• Complete metering, protection, and control in a single compact case to reduce

panel space, wiring and costs.

• Integral test function reduces maintenance time and expense.

• Zone selective interlocking improves coordination and tripping time, and saves

money compared to a traditional bus differential scheme.

• Programmable logic control functions for providing customized protection and

control solutions.

• Reduce trouble shooting time and maintenance costs- Trip and event recording

in non-volatile memory provides detailed information for analysis and system

restoration. 6000 cycles of waveform capture aids in post fault analysis (viewable

using Powerport-E software)

• Minimum replacement time- Removable terminal blocks ideal in industrial

environments

• Front RS-232 port and Powerport-E software provides local computer access and

user-friendly windows based interface for relay settings, configuration, and data

retrieval.

• Breaker open/close from relay faceplate or remotely via communications.

• Fast and easy troubleshooting, improved maintenance procedures and increased

device security. Provides detailed traceability for system configuration changes.

• Relays self-diagnostics and reporting improves uptime and troubleshooting.

Eaton generator relay EGR5000

Eaton’s Generator Relays (EGR5000) are preferred by users because of their

unmatched versatility and dependability. These multifunctional relays provide

control and backup protection for medium- to large-sized generators.

The EGR’s zone-selective interlocking function improves coordination and

tripping time. The unique design provides complete metering, protection,

and control in a single compact case, saving panel space and overall cost.

Communication protocols supported

Eaton generator relays support all of the following communication protocols

as well as the “Do Not Use” option.

• Modbus RTU

• Modbus TCP

• DNP RTU

• DNP TCP

• • DNP UDP

• IEC61850 with GOOSE

• Profibus

Common software tools

All E-series relays, including our E-series motor relays, use the same software

interface for easy access to information and programming of settings. Whether

you are using the front panel or the external software, the interface is the same

on all models.

• Operation

• System Parameters

• Protection Parameters

• Device Parameters

• Control

• Logic

• Device Planning

• Service

Eaton EDR-5000 Control Functions

Control Functions

• Breaker open/close

• Remote open/close

• Programmable I/O

• Programmable Logic

• Programmable LEDs

• Multiple setting groups .

• Cold load pickup .

• CT supervision

Communication Features

• Local HMI .

• Password protected .

• Addressable .

• IRIG-B

• Local USB communication port .

• Configuration software

• Remote communication port:

• RS-485 Terminals

• Ethernet RJ45

• Fiber Optic ST

• RS-485 D-SUB

• LC Duplex Fiber Optic

• Protocols:

• Modbus-RTU

• Modbus-TCP

• IEC-61850

• DNP3-RTU

• DNP3-TCP/UDP

• Profibus-DP

Eaton EDR-5000 Metering Features

Metering Features

• Amperes: Positive, negative and zero sequence .

• Ampere demand .

• Volts: Positive, negative and zero sequence .

• Phase angles .

• Volt-amperes and VA demand .

• Watts and kW demand .

• kWh (forward, reverse, net)

• Vars and kvar demand

• kvarh (lead, leg and net) .

• Power factor .

• Frequency .

• % THD V and I .

• Magnitude THD V and I

• Minimum/maximum recording .

• Sync Values

• Trending (load profile over time)

Monitoring Features

• Trip coil monitor

• Breaker wear primary and secondary (accumulated interrupted

current) .

• Oscillography (6000 cycles total) .

• Fault data logs (up to 20 events) .

• Sequence of events report (up to 300 events) .

• Clock (1 ms time stamping) .

Eaton Protection Features EDR-5000

Features

Protection Features

• Phase overcurrent elements:

• Three instantaneous elements with timers ( 50P[1], 50P[2], and

50P[3])

• Three inverse time overcurrent elements (51P[1], 51P[2], and

51P[3])

• 11 standard curves

• Instantaneous or time delay reset

• Voltage Restraint (51P[2], and 51P[3])

• Directional Control (All Elements)

• Ground overcurrent elements:

• Two instantaneous measured elements with timers (50X[1],

and 50X[2])

• Two instantaneous calculated elements with timers (50R[1],

and 50R[2])

• Two inverse time overcurrent measured elements (51X[1], and

51X[2])

• Two inverse time overcurrent calculated elements (51R[1], and

51R[2])

• 11 standard curves

• Instantaneous or time delay reset

• Directional Control (All Elements)

• Breaker failure (50BF) .

• Phase unbalance negative sequence overcurrent (46[1], 46[2])) .

• Phase voltage unbalance and sequence protection (47[1], 47[2]) .

• Main 3-phase under/overvoltage (27M[1], 27M[2], 59M[1], 59M[2])

• Auxiliary single-phase under/overvoltage (27A[1], 27A[2], 59A[1],

59A[2])

• Ground fault overvoltage relay (59N[1], 59N[2])

• 6 Frequency elements that can be assigned to: over frequency,

under frequency, rate of change, or vector surge (81[1], 81[2],

81[3], 81[4], 81[5], 81[6])

• Apparent and displacement power factor (55A[1], 55A[2], 55D[1],

55D[2]) .

• Forward and Reverse Watts (32[1], 32[2], 32[3])

• Forward and Reverse Vars (32V[1], 32V[2], 32V[3])

• Synch Check (25)

• Autoreclosing (79)

• Zone interlocking for bus protection (87B) .

• Switch onto fault protection

• Cold load pickup

AMAT Applied Materials Aera 6 Mask Inspection

The Applied Aera™ 6 Mask Inspection system is a sixth generation 193nm-based

inspection tool, unique in combining true aerial imaging with cutting-edge

high-resolution imaging.

Equipped with a new lithography-grade lens and double CCD system, the Aera 6

demonstrates enhanced signal-to-noise ratio for both standard high-resolution

applications and aerial inspection with improved throughput. Such capabilities

makes it the tool of choice for Memory and Logic most advanced nodes, including

those with aggressive optical proximity correction, such as inverse lithography

and EUV mask inspection. The system performs highly sensitive mask inspection,

as required for double- and quadruple-patterning lithography technologies, while

maintaining a very low false alarm rate.

Designed to emulate a lithography scanner, the Aera 6 system delivers a higher

inspection success rate over other high-resolution inspection systems with

advanced masks. Combined with its inherent automatic defect classification as

printing or non-printing, and by focusing on advanced AI algorithmic solutions,

the system allows mask makers to extend ArF technology to next-generation

nodes.

The Aera 6 system expands the mask inspection capabilities of mask shops and

fabs to promote longer mask lifetimes and reduce mask-related costs.

These capabilities include early haze detection, complete 193nm and EUV exposure

-degradation monitoring, 2.5nm resolution review of edge dislocation defects, and

full-mask critical dimension (CD) uniformity mapping using the IntenCD™ system.​

AMAT Applied Materials Cmp Tool Controller 0195-14157

Overview

This is a rack-mount industrial PC / system controller assembly for AMAT CMP

(Chemical Mechanical Planarization) semiconductor polishing tools, assembled

in USA. It acts as the main process control unit for CMP polishing head, platen,

slurry, endpoint, motion and I/O sequencing of the wafer planarization system.

Main Internal Components

Industrial motherboard: ADLINK MI-220

DAC/ADC board: PCB 1007-0101

Interface board: T115-0005 / PCB 1007-0097 REV 2C

Power supply: SOLA SDN 20-24-100C (24V DC power module)

Mechanical & Physical Info

Form factor: 4U rack mount enclosure with front handles

Weight: ~22 kg

Front panel: Power switch + 6 control buttons

Rear panel: Multiple DB serial ports, USB, power inlet, analog/digital I/O terminals

Cooling: Internal fan forced air cooling

Function

• Host control of CMP process recipe execution

• Real-time acquisition of polishing pressure, platen speed, temperature, slurry

flow and endpoint signals

• Motion control and interlock safety logic for CMP polishing head and platens

• Communication between tool host, chamber sensors and actuator subsystems

• Data logging, fault diagnosis and tool state management for CMP platform

Application

Applied Materials Reflexion series 300mm CMP polishing tools for wafer

planarization in semiconductor fab.

The EDR-5000 distribution protection relay includes programmable logic functions

The EDR-5000 distribution protection relay includes programmable

logic functions . Logic gates and timers may be defined and arranged

for customized applications . Programmable logic control functions

make the EDR-5000 relay ideally suited for main-tie-main and main

1/main 2 transfer schemes . Flash memory is used for the program

ming and all settings are stored in nonvolatile memory . The relay

allows for four preprogrammed setting groups which can be acti

vated through software or contact input .

Flash memory is used for the programming and all settings are

stored in nonvolatile memory . The relay allows for four prepro

grammed setting groups which can be activated through software,

the display or a contact input .

The EDR-5000 distribution protection relay has mass memory for

data storage and a real-time clock with 1 ms time resolution . The

relay will log 300 sequence of event records, 20 detailed trip logs,

minimum/maximum values, load profiles, breaker wear information

and oscillography data .

The EDR-5000 has eight programmable binary inputs, 2 normally

opened and 8 Form C heavy duty outputs and one form C signal

alarm relay . It can be powered from 19 Vdc to 300 Vdc or 40 Vac to

250 Vac auxiliary power