Aerotech EPICS & TANGO Key Features

Key Features

• Ready-to-use, open source device drivers developed in partnership

with Argonne National Laboratory and Observatory Sciences

• Motion control integration made simple – tested & verified

• Open source drivers

• Unlocks the power of Aerotech motion control

• Powers position synchronized output (PSO) position-based process

control

• Supports absolute encoder & EtherCat

• Features powerful configuration & tuning tools

• Develops applications for the Linux operating system

Automation1

The Automation1 EPICS & TANGO drivers are part of the user-friendly

Automation1 motion control platform, which includes the following:

• Development Software

• Controls

• Motor Drives

• Fiber-Optic HyperWire® Communication Bus

Aerotech EPICS & TANGO Drivers for Distributed Control Systems

We developed EPICS and TANGO drivers for the Automation1 motion

control platform in partnership with laboratory control system experts

at Argonne National Laboratory and Observatory Sciences.

This means the motor drivers are ready to use and have an open

source interface. Automation1 also has .NET, C and Python APIs for

building Windows and Linux applications.

EPICS and TANGO provide a common language for scientists using

experimental science facilities. Our Automation1 motion control 

platform is the premier standard in precision motion control and

includes new PWM and linear amplifier technology, superior configuration

and setup tools, absolute encoder support, the innovative fiber-optic

HyperWire motion bus, and our Position Synchronized Output (PSO)

feature that provides process triggers based on actual position—making

detector triggering and position capture easy.

ICS TRIPLEX T8451 Front Panel Unit (FPU)

Front Panel Unit (FPU)

The Front Panel Unit (FPU) contains the necessary connectors, switches,

logic, and LED indicators for the Front Panel. For every type of Trusted I/O

Module, the FPU contains the Slice Healthy, Active/Standby, the Educated

LED indicators, and the Module removal switches. Additional bicolor LEDs

provide status indication for the individual I/O signals. Serial data interfaces

connect the FPU to each of the HIU slices to control the LED status indicators

and monitor the Module removal switches.

The FIU receives isolated power from the HIU for logic. The FIU provides

additional power conditioning for the operational voltages required by the

FIU circuitry. An isolated 6.25 Mbit/sec serial link connects each FIU to one of

the HIU slices.

The FIU also measures a range of onboard “housekeeping” signals that assist

in monitoring the performance and operating conditions of the Module.

These signals include power supply voltages, current consumption, onboard

reference voltages and board temperature.

ICS TRIPLEX T8451 Host Interface Unit (HIU)

Host Interface Unit (HIU)

The HIU is the point of access to the Inter-Module Bus (IMB) for the Module.

It also provides power distribution and local programmable processing

power. The HIU is the only section of the I/O Module to directly connect to the

IMB Backplane. The HIU is common to most high integrity I/O types and has

type dependent and product range common functions. Each HIU contains

three independent slices, commonly referred to as A, B, and C.

All interconnections between the three slices incorporate isolation to help

prevent any fault interaction between the slices. Each slice is considered a

Fault Containment Region (FCR), as a fault on one slice has no effect on the

operation of the other slices.

The HIU provides the following services common to the Modules in the

family:

• High-Speed Fault Tolerant Communications with the TMR Processor

via the IMB interface.

• FCR Interconnect Bus between slices to vote incoming IMB data and

distribute outgoing I/O Module data to the IMB.

• Galvanically isolated serial data interface to the FIU slices.

• Redundant power sharing of dual 24 Vdc chassis supply voltage and

power regulation for logic power to HIU circuitry.

• Magnetically isolated power to the FIU slices.

• Serial data interface to the FPU for Module status LEDs.

• SmartSlot link between Active and Standby Modules for coordination

during Module replacement.

• Digital Signal Processing to perform local data reduction and

self-diagnostics.

• Local memory resources for storing Module operation, configuration,

and field I/O data.

• Onboard housekeeping, which monitors reference voltages, current

consumption and board temperature.

ICS TRIPLEX T8451 Field Interface Unit (FIU)

Field Interface Unit (FIU)

The Field Interface Unit (FIU) is the section of the Module that contains the

specific circuits necessary to interface to the particular types of field I/O

signals. Each Module has three FIUs, one per slice. For the TMR 24 Vdc Digital

Output Module, the FIU contains one stage of the output switch structure,

and sigma-delta (ΣΔ) output circuit for each of the 40 field outputs. Two

additional ΣΔ circuits provide optional monitoring of the external field I/O

supply voltage.

The FIU receives isolated power from the HIU for logic. The FIU provides

additional power conditioning for the operational voltages required by the

FIU circuitry. An isolated 6.25 Mbit/sec serial link connects each FIU to one of

the HIU slices.

The FIU also measures a range of onboard “housekeeping” signals that assist

in monitoring the performance and operating conditions of the Module.

These signals include power supply voltages, current consumption, onboard

reference voltages and board temperature.

ICS TRIPLEX T8451 Field Termination Unit (FTU)

Description

The TMR 24 Vdc Digital Output Module is a member of the Trusted range of

input/output (I/O) Modules. All Trusted I/O Modules share common

functionality and form. At the most general level, all I/O Modules interface to

the Inter-Module Bus (IMB) which provides power and allows communication

with the TMR Processor. In addition, all Modules have a field interface that is

used to connect to Module-specific signals in the field. All Modules are Triple

Modular Redundant (TMR).

All High Integrity I/O Modules are made up of four sections: Host Interface

Unit (HIU), the Field Interface Unit (FIU), the Field Termination Unit (FTU),

and the Front Panel Unit (or FPU).

Field Termination Unit (FTU)

The Field Termination Unit (FTU) is the section of the I/O Module that

connects all three FIUs to a single field interface. The FTU provides the Group

Fail-Safe Switches and passive components necessary for signal conditioning,

overvoltage protection, and EMI/RFI filtering. When installed in a Trusted

Controller or Expander Chassis, the FTU field connector interconnects to the

Field I/O Cable Assembly attached at the rear of the Chassis.

The SmartSlot link is passed from the HIU to the field connections via the

FTU. These signals go directly to the field connector and maintain isolation

from the I/O signals on the FTU. The SmartSlot link is the intelligent

connection between Active and Standby Modules for coordination during

Module replacement.

ICS TRIPLEX T8451 Features

Features

• 40 Triple Modular Redundant (TMR) output points per Module.

• Comprehensive, automatic diagnostics and self-test.

• Automatic line monitoring per point to detect open circuit and short

circuit field wiring and load faults.

• 2500V impulse withstand opto/galvanic isolation barrier.

• Automatic overcurrent protection (per channel), no external fuses

required.

• Onboard Sequence of Events (SOE) reporting with 1 ms resolution.

• Module can be hot-replaced online using dedicated Companion

(adjacent) Slot or SmartSlot (one spare slot for many Modules)

configurations.

• Front Panel output status light-emitting diodes (LEDs) for each point

indicate output status and field wiring faults.

• Front Panel Module status LEDs indicate Module health and

operational mode (Active, Standby, Educated).

• TϋV Certified IEC 61508 SIL 3.

• Outputs are powered in isolated groups of eight. Each such group is a

Power Group (PG).

ICS TRIPLEX Trusted® TMR 24 Vdc Digital Output Module

Product Overview

The Trusted® TMR 24 Vdc Digital Output Module interfaces to 40 field

devices. Triplicated diagnostic tests are performed throughout the Module

including measurements for current, and voltage on each portion of the voted

output channel. Tests are also performed for stuck on and stuck off failures.

Fault tolerance is achieved through a Triple Modular Redundant (TMR)

architecture within the Module for each of the 40 output channels.

Automatic line monitoring of the field device is provided. This feature enables

the Module to detect both open and short circuit failures in field wiring and

load devices.

The Module provides onboard Sequence of Events (SOE) reporting with a

resolution of 1 ms. An output change of state triggers an SOE entry. Output

states are automatically determined by voltage and current measurements

onboard the Module.

This Module is not approved for direct connection to hazardous areas and

should be used in conjunction with Intrinsic Safety Barrier devices.

Basler Electric FGD-2 continuously monitors the machine field circuit for ground faults

Operation

The FGD-2 continuously monitors the machine field circuit for ground faults.

Ground faults are detected through the measurement of leakage current to

ground which is determined by measuring the voltage drop across a shunt

resistor within the ground detector source. The Basler device connected to

the FGD-2 receives a voltage signal from the ground detection source that

is proportional to the level of field leakage current. The excitation

capabilities and analog input ranges of different Basler products will limit

the maximum compatible field voltage for accurate field ground resistance

measurements. Refer to Table 2 for more details.

AIOM-2

In a DECS-2100 system, the AIOM-2/AIOM digitizes the signal and transmits

it via fiber optic cables to the ECM-2. In an ECS2100 system, the digitized

signal is received by the ECM/SIM. The value of leakage current appears as

an input to the BESTCOMS™Pro FLDGND logic block. Within the FLDGND

logic block, a value of resistance to ground is calculated from the voltage

applied and the level of leakage current measured. Typically, this calculated

resistance value is transmitted to a display panel via the PMOUT logic block.

In the event of a low field ground resistance value, the FLDGND logic block

issues a Low Field Ground Resistance alarm. During detection of low field

ground resistance, an alarm issued by the DIGROUT logic block can be used

to energize a relay within the system’s Digital I/O Module (DIOM-2 or DIOM).

This annunciation may be used to provide a dry relay contact for a remote

alarm.

Beckhoff EL3124-0090 | EtherCAT Terminal, 4-channel analog input, current, 4…20 mA, 16 bit

The EL3124-0090 analog input terminal handles signals in the range

from 4 to 20 mA. The current is digitized to a resolution of 16 bits

and is transmitted, in an electrically isolated form, to the higher-level

automation device. The input channels of the EtherCAT Terminal have

differential inputs and possess a common, internal ground potential.

With the aid of the TwinSAFE SC technology (TwinSAFE Single Channel)

it is possible to make use of standard signals for safety tasks in any

network or fieldbus. To do this, EtherCAT I/Os from the areas of analog

input, position measurement or communication (4… 20 mA, incremental

encoder, IO-Link, etc.) are extended by the TwinSAFE SC function.

The properties typical for the signals and the standard functions of the

I/O components are retained. TwinSAFE SC I/Os differ optically from

standard I/Os by a yellow stripe on the front of the housing.

The TwinSAFE SC technology enables communication via a TwinSAFE

protocol. These connections can be distinguished from the usual secure

communication via Safety over EtherCAT.

The data from the TwinSAFE SC components is fed via a TwinSAFE

protocol to the TwinSAFE Logic, where it can be used in the context of

safety-relevant applications. Detailed examples confirmed/calculated by

the TÜV SÜD for the correct application of the TwinSAFE SC components

and the respective normative classifications can be found in the TwinSAFE

application manual.