Bachmann BPS1nn Backplanes for direct screw mounting

The backplane combines the node adapter and the I/O

modules into a mechanically robust EMC compliant unit.

Fully assembled I/O stations can thus be pre-tested after

mounting and transferred to the application without fur

ther modification. This assembly enables individual mod

ules to be exchanged and retrofitted without having to

remove the unaffected modules.

The backplane enables real-time communication between

modules as well as with the node adapter, provides the

power supply to the logic side of the modules and enables

module-to-module communication.

Fastening with solid M5 screws makes this variant ideal for

environments that are exposed to high shock and vibration

loads. The solid metal body and large mounting area on the

rear allow high heat dissipation to the support structure.

This increases thermal reserves for applications involving

high ambient temperatures.

Features

● M100 system backplane for screw mounting

● 4 to 32 slots

● Mechanically robust, self-supporting base for modules

● Module exchange without the removal of other mod

ules

● Enables complete pre-assembly and testing

● Any slots possible as reserve (gaps)

● Enhanced heat dissipation via rear mounting surface

Bachmann BPR1nn Busschienen für Tragschienenmontage

Die Busschiene vereint den Buskoppler und die I/O-Module

zu einer mechanisch robusten, EMV-sicheren Einheit, die

sich mit einem Handgriff auf einer normkonformen Trag

schiene aufsetzen und auch wieder abnehmen lässt. Voll

ständige I/O-Stationen können somit nach der Montage

vorgetestet und ohne weitere Veränderung in die Anwen

dung übernommen werden. Der Aufbau ermöglicht Tausch

und Nachrüstung einzelner Module ohne Demontage der

nicht betroffenen Module.

Die Busschiene ermöglicht die Echtzeitdatenkommunika

tion zwischen den Modulen und dem Buskoppler, versorgt

die Logikseite der Module mit Energie und ermöglicht die

Modul-zu-Modulkommunikation.

Features

● Busschiene System M100 für Tragschienenmontage

● 4 bis 32 Steckplätze

● Mechanisch robuste, selbsttragende Basis für Module

● Modultausch ohne Demontage anderer Module

● Ermöglicht vollständige Vormontage und Test

● Beliebige Steckplätze als Reserven möglich (Lücken)

Bachmann BPR1nn Backplanes for DIN-rail mounting

The backplane combines the node adapter and the I/O

modules into a mechanically robust, EMC compliant unit

that can be fitted on a standard DIN mounting rail and

also removed in an instant.

Fully assembled I/O stations can thus be pre-tested after

mounting and transferred to the application without

further modification. This assembly enables individual

modules to be exchanged and retro fitted without

having to remove the unaffected modules.

The backplane enables real-time communication between

modules as well as with the node adapter, provides the

power supply to the logic side of the modules and enables

module-to-module communication.

Features

● M100 system backplane for DIN-rail mounting

● 4 to 32 slots

● Mechanically robust, self-supporting base for modules

● Module exchange without the removal of other modules

● Enables complete pre-assembly and testing

● Any slots possible as reserve (gaps)

Bachmann System Modules / Basic Components Ingenious mounting concept

The backplane combines the node adapter and the I/O modules into

a mechanically robust EMC compliant unit. Fully assembled I/O stations

can thus be pre-tested after mounting and transferred to the application

without further modification. Backplanes allow for real-time communication

between modules as well as with the node adapter and provide the power

supply to the logic side of the modules.

The IP40 conform structure and the installation concept of the M100 make

it possible to mount the stations directly on or in the machine, either on a

mounting rail or through direct screw mounting. In addition, the individual

modules are bolted and they remain fixed in place, even if subjected to

vibration or shock loads.

Empty slots on backplanes are useful for optional retrofits, machine

variants or for keeping reserve space in plant construction.

The BPC101 backplane slot cover protects each slot from mechanical

influences, electrostatic discharge and contamination.

Bachmann NPN102 Node Adapter PROFINET RT

The NPN102 PROFINET RT node adapter maps the pow

erful and flexibly configurable M100 station to a standard

PROFINET interface. The operating modes of the M100

I/O modules are defined during the configuration and are

transferred to the station node during start-up.

Features

● PROFINET RT device

● Integrated 2-port switch for line cabling

● Integrated power supply unit for module supply: 20 W

● Diagnostics LEDs according to PROFINET recommendation

Bachmann NCN102 Node Adapter CAN/CANopen

The NCN102 node adapter maps the powerful and flexibly

configurable M100 station to a standard CANopen inter

face. The operating modes of the M100 I/O modules are

defined during the configuration and are transferred to

the station node during start-up. The CANopen synchroni

zation features enables clock-synchronous sampling and

processing of the I/O signals.

Features

● CAN/CANopen node adapter

● Wiring on M100 standard terminal block

● Integrated termination resistor

● Address configuration: via 2 rotary switches, or via LSS

service according to CiA 305

● Baud rate setting: via rotary switches, or automatic

detection

● Synchronization: CANopen sync consumer

● Maximum process image per station: 2048 bytes

● Integrated power supply unit for module supply: 20 W

● Diagnostic LEDs according to CANopen standard

Bachmann NCN102. NCN102/D Node Adapter CAN/CANopen

The NCN102 node adapter maps the powerful and flexibly

configurable M100 station to a standard CANopen inter

face. The operating modes of the M100 I/O modules are

defined during the configuration and are transferred to

the station node during start-up. The CANopen synchroni

zation features enables clock-synchronous sampling and

processing of the I/O signals.

Features

● CAN/CANopen node adapter

● Available with either a M100 standard terminal block or

2x 9-pin D-sub ports

● Integrated termination resistor

● Address configuration: via 2 rotary switches, or via LSS

service according to CiA 305

● Baud rate setting: via rotary switches, or automatic

detection

● Synchronization: CANopen sync consumer

● Maximum process image per station: 2048 bytes

● Integrated power supply unit for module supply: 20 W

● Diagnostic LEDs according to CANopen standard

Bachmann NEC102 Node Adapter EtherCAT

The NEC102 node adapter maps the powerful and flexibly

configurable M100 station to a standard EtherCAT inter

face.

The operating modes of the M100 I/O modules are

defined during the configuration and are available to both

the Bachmann main device and also to main devices of

other manufacturers. Thanks to distributed clocks on the

EtherCAT stations, the implementation of short control

intervals across the entire control system is given.

Features

● EtherCAT fieldbus IO node adapter

● 2x RJ45 connections (1x EtherCAT in, 1x EtherCAT out)

● Address configuration: automatic / SW

● Synchronization: Distributed clocks (DC)

● EtherCAT PDO/SDO, FoE

● Maximum process image / station: 14 506 bytes

● Minimum bus cycle time: 100 µs

● Integrated power supply unit for module supply: 20 W

Bachmann Fieldbus Node Adapter Standard-compliant and high performing

A new dimension in decentralized peripherals – with the M100 series,

Bachmann is launching an I/O system that not only fits perfectly into

the Bachmann portfolio with its uncompromising robustness, but also

opens up completely new possibilities for machine and plant builders

due to its compact design.

Modular machine concepts in demanding environments significantly

reduce the costs of variants. The decentralized positioning of I/O

stations also reduces wiring efforts, and therefore costs. With the

M100 I/O system, up to 744 digital or 372 analog channels per

station can be positioned cost-effectively in the smallest possible

space.

For the first release, Bachmann has implemented EtherCAT as a

standardized, real-time capable fieldbus. The NEC102 node adapter

maps the powerful and flexibly configurable M100 station to a

standard EtherCAT interface. The operating modes of the M100 I/O

modules are defined during the configuration and are available to

both an Bachmann master as well as to masters of other manufacturers.

Thanks to distributed clocks on the EtherCAT stations that can be

synchronized with external time servers, the implementation of short

control intervals across the entire control system is given.

The Bachmann hardware platform design is at the very latest state

of the art: System architectures, processors, logic, and signal interfaces

are based on the newest technologies and provide a backbone for

minimal power dissipation, ultra-fast data transmission and next-generation

IT security. Secure Boot initialization prevents the compromise of fieldbus

hardware and allows for the secure integration of remote I/O stations into

the automation network.

Bachmann COM102. COM102/D, COM104 Serial Interface Modules

The module for the backplane offers 2 resp. 4 serial inter

faces. The standards RS-485. RS-422 and RS-232 can be

selected as well as the baud rate and the handshake proce

dure. The interfaces can be used with the communication

solutions for Modbus RTU/ASCII, IEC 60870-5-101 and -103

or DNP3. Customized protocols can be implemented in PLC

and C/C++. Thanks to the native mapping of the COM ports

in the operating system of the controller CPU, no fieldbus

data points need to be considered in the application pro

gram. The LEDs on the module enable targeted diagnostics

in the switch cabinet even without a PC.

Features

● Module for the M100 backplane

● 2 or 4 serial interfaces

● Protocols RS-232. RS-422 or RS-485 configurable foreach port

● The ports are galvanically isolated against each other

and against the ground (GND) of the backplane

● Integrated termination resistor, switchable via configuration

● Diagnostic LED for module status

● Status LED for each COM port:– Rx, Tx activity– Display of buffer

overflow Error indication: Parity, Frame, Overflow, … (configurable)

– State of terminating resistor